Optimization of SPECT Imaging

Optimization of SPECT Cardiac Imaging Through Compensation for Attenuation, Resolution Loss and Scatter - The OSCARS

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01519973
Acronym
OSCARS
Enrollment
64
Registered
2012-01-27
Start date
2008-08-31
Completion date
2012-08-31
Last updated
2017-04-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Diagnostic imaging, Single Photon Emission Computed Tomography, Positron emission tomography, Computed tomography, Attenuation, Resolution, Scatter, Radiopharmaceutical

Brief summary

Single Photon Emission Computed Tomography (SPECT) is a 3D nuclear medicine imaging technique that is used extensively to study the heart and diagnose heart disease. There are three major limitations in SPECT imaging: attenuation or loss of signal, scattering of the signal in the patient tissues and resolution, where the signal gets blurrier the further the nuclear activity is away from the camera. New software, Evolution for CardiacTM, by GE Healthcare and new cameras with computed tomography (CT) decrease the time needed for images to be obtained while maintaining image quality. Evaluation is needed before they become standard of care.

Interventions

RADIATIONSPECT/CT processed with Evolution for CardiacTM software

SPECT/CT to be compared with PET/CT

Sponsors

Ottawa Heart Institute Research Corporation
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Intermediate to high risk patients with coronary artery disease who are scheduled for routine SPECT or PET perfusion imaging

Exclusion criteria

* Pregnancy and breast feeding * Severe narrowing (stenosis) of the aortic valve * Severe heart failure

Design outcomes

Primary

MeasureTime frameDescription
• Determine the accuracy of myocardial perfusion assessment using SPECT with AC/SC/RR compared to Rb-82 PET.2 yearsWe are proposing a study to evaluate the accuracy of SPECT with the new technologies for attenuation correction (AC), scatter compensation (SC) and resolution recovery (RR) for the assessment of myocardial perfusion in patients with heart disease using Rb-82 perfusion PET as the gold standard for comparison.

Secondary

MeasureTime frame
Determine the incremental benefit of AC/SC/RR compared to AC alone2 years
Evaluate the effect on accuracy of using software with RR to reduce the acquisition time to half of the standard time.2 years
Determine if using a registered diagnostic CT (PET) increases the accuracy of CT-based AC over the lower-quality Hawkeye CT (SPECT).2 years
Determine if using a single CT scan acquired at stress for attenuation correction of both stress and rest SPECT decreases the accuracy over using CT scans acquired separately at rest and stress.2 years

Countries

Canada

Outcome results

None listed