Evaluation of a Dry Powder Aerosol Dispersion Mechanism by Radiolabeling Techniques

Evaluation of a Dry Powder Aerosol Dispersion Mechanism by Radiolabeling Techniques

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01495442
Acronym
DPI
Enrollment
6
Registered
2011-12-20
Start date
2011-12-31
Completion date
2012-06-30
Last updated
2017-01-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Adult Healthy Volunteers

Brief summary

The primary objective is to admix a radiolabel with albuterol sulphate for incorporation into the Handihaler® device for inhalation studies. This will allow for the investigators to determine the regional lung deposition of drug inhaled from the standard Handihaler® device compared to a novel modification of the device to provide more effective dispersion and aerosolization of the coated albuterol powder. The new mechanism of action for proof-of-concept testing consists of a bead (5.1 mm; expanded polystyrene foam) coated with drug powder, as opposed to the standard lactose formulation-filled capsule.

Interventions

DEVICEmodified Handihaler DPI

subjects randomized to receive 1 inhaled dose on 2 separate days, each dose delivered 2-3 days apart. The radiolabeled albuterol drug powder will be dispersed from either the DET bead-HandiHaler prototype or via the established HandiHaler device standard with the lactose-albuterol formulation provided to us by the sponsor.

DEVICEstandard Handihaler DPI

subjects randomized to receive 1 inhaled dose on 2 separate days, each dose delivered 2-3 days apart. The radiolabeled albuterol drug powder will be dispersed from either the DET bead-HandiHaler prototype or via the established HandiHaler device standard with the lactose-albuterol formulation provided to us by the sponsor.

Sponsors

University of Texas at Austin
CollaboratorOTHER
University of North Carolina, Chapel Hill
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
BASIC_SCIENCE
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* healthy volunteers adults

Exclusion criteria

* chronic illness

Design outcomes

Primary

MeasureTime frameDescription
Fractional delivery of dry powder to the lung1-5 minutes post inhalationTo compare the in vivo performance,i.e. the fraction of drug loaded in device that is delivered to the lung, of the novel system in comparison with a standard marketed dry powder inhaler (DPI) using radio-imaging techniques. The fraction delivered to the lung will be determined by gamma camera imaging of the lungs following inhalation of the radiolabeled powder from the standard vs. new device.

Countries

United States