Skip to content

The Effect of Nitroglycerin on the Intrauterine Device (IUD) Insertion Experience in Nulliparous Women

The Effect of Nitroglycerin on the IUD Insertion Experience in Nulliparous Women: a Pilot Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01490073
Enrollment
24
Registered
2011-12-12
Start date
2012-03-01
Completion date
2012-11-01
Last updated
2019-04-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Contraception, Pain

Keywords

Intrauterine device, Pain, Contraception, Nitroglycerin, Nitric oxide donor, Intrauterine device insertion

Brief summary

Increasing ease of access of long-acting birth control methods, like intrauterine devices (IUDs), is an important way to reduce the risk of unintended pregnancy. Unfortunately, fear of IUD insertion in women who have not had children is common among health care providers and women alike, and this limits IUD use. To increase acceptance of this highly effective birth control method, there is a need to explore new, low cost, and easily applied methods to improve the insertion experience. This is a pilot study to evaluate the effectiveness and acceptability of nitroglycerin ointment applied vaginally to improve the IUD insertion experience for both patient and provider. The investigators hypothesis is that nitroglycerin ointment will decrease the pain associated with IUD insertion.

Detailed description

Increasing acceptability and use of long acting reversible contraceptive methods like the intrauterine device (IUD) is an important strategy to reduce the risk of unintended pregnancy. Unfortunately, fear of IUD insertion in nulliparous women is common among health care providers and women alike, and this limits IUD use. While many health care providers assume that placement is more difficult in nulliparous women, there is no evidence that the risk of unsuccessful insertion is higher. Women worry about pain with insertion, and their fear is not unfounded as U.S. and international data have shown that nulliparous women report approximately twice as much pain with IUD insertion compared to parous women. A key difference between nulliparous and multiparous women is the resistance of the cervix. While cervical dilation is uncommonly needed during IUD placement, force is often required to pass the insertion device through the internal os. Although misoprostol and ibuprofen have been studied as ways to improve the IUD insertion experience, neither has proved effective, and misoprostol actually has been shown to increase pain. Therefore, to increase acceptance of this highly effective contraceptive, there is a need to investigate novel, low cost, easily applied and accessible techniques to improve the insertion experience. Nitric oxide (NO) donors, including nitroglycerin, nitroprusside, isosorbide mononitrate and isosorbide dinitrate, have effects on the animal and human cervix. Both nitroglycerin and isosorbide mononitrate tablets administered vaginally have been shown in RCTs to induce effective cervical ripening with minimal side effects for first trimester abortion compared to placebo. Nitroprusside and isosorbide dinitrate gel given intracervically prior to first trimester abortion also have showed minimal side effects in several RCTs, but with mixed results regarding effectiveness. Additional safety data about NO donors applied topically to skin and mucosal surfaces is well established through the routine use of topical nitroglycerin for treatment of anal fissures. Although a recent randomized controlled trial (RCT) comparing nitroprusside gel to misoprostol for cervical ripening prior to first trimester surgical abortion found superior cervical dilation in the misoprostol group, there was no significant difference in cervical dilation up to 5 mm. While most studies of abortion are concerned with providing adequate dilation beyond 8 mm, the cervical remodeling that is necessary to help with IUD insertion is much less, as the levonorgestrel intrauterine system (LNG-IUS) inserter is only 4.75 mm in diameter. Since NO donors are smooth muscle relaxants, they are expected to induce cervical ripening without causing uterine cramping, which is the most significant side effect of misoprostol. Nitroglycerin is inexpensive, stable at room temperature, and readily available in tablet and ointment form, as well as in a dextrose solution for intravenous administration. The ointment form is commonly applied topically for the treatment of anal fissures. We propose the following aims: 1. To determine if nitroglycerin ointment applied vaginally 30-45 minutes prior to IUD insertion improves pain among nulliparous women compared to a placebo ointment. Self-reported pain scores on a 100 mm VAS will be assessed at multiple time points during and after the IUD insertion procedure. In addition, overall satisfaction and adverse effects will be evaluated. 2. To determine if nitroglycerin ointment applied vaginally 30-45 minutes prior to IUD insertion improves ease of IUD insertion for the provider compared to a placebo ointment. In addition, need for additional dilation, additional pain medicine such as paracervical block, inability to place the IUD, and complications will be tracked. 3. To determine if nitroglycerin ointment applied vaginally 30-45 minutes prior to IUD insertion is safe and well tolerated. Side effects related to treatment with nitroglycerin ointment or placebo will be compared. Blood pressure will be measured at multiple time points.

Interventions

DRUGInsertion of nitroglycerin ointment

Nitroglycerin ointment inserted into the vagina 30-45 minutes prior to IUD insertion

DRUGInsertion of placebo ointment

Placebo ointment inserted into the vagina 30-45 minutes prior to IUD insertion

Sponsors

American College of Obstetricians and Gynecologists
CollaboratorOTHER
Bayer
CollaboratorINDUSTRY
Oregon Health and Science University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

1. age 18-45 years, 2. generally healthy, 3. requesting a LNG-IUS for contraception as the primary indication

Exclusion criteria

1. Previous pregnancy beyond 20 weeks; 2. previous IUD placement or attempted IUD placement; 3. previous cervical cold knife cone (CKC) or loop electrosurgical excision procedure (LEEP); 4. contraindication to LNG-IUS (including pregnancy, fibroids that distort the uterine cavity, exam consistent with PID, allergy to any component of the LNG-IUS, etc); 5. concurrent use of any form of nitrate therapy or medications that interact with nitroglycerin (such as phosphodiesterase V inhibitors); 6. known allergy to nitroglycerine or common topical ointment ingredients; 7. known renal or hepatic impairment; 8. history of hypertensive or hypotensive disorder; 9. history of migraine, cluster headaches, or vascular headaches; 10. history of myocardial infarction; 11. uncontrolled congestive heart failure; 12. unstable angina; 13. tobacco or alcohol amblyopia; 14. congenital optic atrophy; 15. blood pressure less than 90/55 or greater than 150/100 in office prior to speculum exam

Design outcomes

Primary

MeasureTime frameDescription
Patient-reported Pain at Passage of Insertion Device Through Cervix, as Measured on a 100 mm VAS30-45 minutes after insertion of nitroglycerin ointmentPatient-reported pain at passage of insertion device through cervix, as measured on a 100 mm VAS. VAS anchors: 0 indicates no pain, and 100 indicates worst pain imaginable.

Secondary

MeasureTime frameDescription
Provider Ease With Intrauterine Device Insertion Measured on a 100 mm VAS30-45 minutes after insertion of nitroglycerin ointmentProvider ease with intrauterine device insertion measured on a 100 mm VAS. VAS (visual analog scale) anchors: 0 indicates easiest insertion imaginable, 100 indicates most difficult insertion imaginable

Countries

United States

Participant flow

Participants by arm

ArmCount
Active Nitroglycerin Ointment
Insertion of nitroglycerin ointment: Nitroglycerin ointment inserted into the vagina 30-45 minutes prior to IUD insertion
12
Placebo Ointment
Insertion of placebo ointment: Placebo ointment inserted into the vagina 30-45 minutes prior to IUD insertion
12
Total24

Baseline characteristics

CharacteristicActive Nitroglycerin OintmentPlacebo OintmentTotal
Age, Continuous28.3 years
STANDARD_DEVIATION 6.9
25.7 years
STANDARD_DEVIATION 4.4
27.04 years
STANDARD_DEVIATION 5.7
Current smoker4 Participants3 Participants7 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants3 Participants3 Participants
Race (NIH/OMB)
White
12 Participants9 Participants21 Participants
Sex: Female, Male
Female
12 Participants12 Participants24 Participants
Sex: Female, Male
Male
0 Participants0 Participants0 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 120 / 12
other
Total, other adverse events
0 / 120 / 12
serious
Total, serious adverse events
0 / 120 / 12

Outcome results

Primary

Patient-reported Pain at Passage of Insertion Device Through Cervix, as Measured on a 100 mm VAS

Patient-reported pain at passage of insertion device through cervix, as measured on a 100 mm VAS. VAS anchors: 0 indicates no pain, and 100 indicates worst pain imaginable.

Time frame: 30-45 minutes after insertion of nitroglycerin ointment

ArmMeasureValue (MEAN)Dispersion
Active Nitroglycerin OintmentPatient-reported Pain at Passage of Insertion Device Through Cervix, as Measured on a 100 mm VAS55.8 mmStandard Deviation 25.2
Placebo OintmentPatient-reported Pain at Passage of Insertion Device Through Cervix, as Measured on a 100 mm VAS53.9 mmStandard Deviation 28.1
Secondary

Provider Ease With Intrauterine Device Insertion Measured on a 100 mm VAS

Provider ease with intrauterine device insertion measured on a 100 mm VAS. VAS (visual analog scale) anchors: 0 indicates easiest insertion imaginable, 100 indicates most difficult insertion imaginable

Time frame: 30-45 minutes after insertion of nitroglycerin ointment

ArmMeasureValue (MEAN)Dispersion
Active Nitroglycerin OintmentProvider Ease With Intrauterine Device Insertion Measured on a 100 mm VAS29.4 mmStandard Deviation 23.8
Placebo OintmentProvider Ease With Intrauterine Device Insertion Measured on a 100 mm VAS22.8 mmStandard Deviation 29.9

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026