Variability of Pentacam-derived Back Elevation Measurements in Keratoconus and Cross-linked Corneas

Variability of Pentacam-derived Back Elevation Measurements in Keratoconus and Cross-linked Corneas

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01471873
Enrollment
67
Registered
2011-11-16
Start date
2011-03-31
Completion date
2011-11-30
Last updated
2017-01-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Keratoconus

Keywords

Posterior corneal surface elevation, Pentacam-Scheimpflung imaging, variability, progressive keratoconus, corneal cross-linking

Brief summary

Primary objective of this study was to assess the intrasession, intersession and interobserver variability of the Pentacam-derived posterior corneal elevation measurements in keratoconus eyes and eyes that underwent Corneal Collagen Cross-liknking (CxL) treatment due to progressive keratoconus.

Detailed description

The Pentacam Classic (Oculus Optikgerate GmbH, Heidelberg, Germany, software version 1.14r04) was used for the sake of the study.Two study groups were formed: 1) Keratoconus group (KC) included patients with progressive keratoconus and 2) Collagen-Cross-linking group (CXL) included keratoconus patients that had been treated with uneventful CXL at least on year prior to their enrollment in the study. Three consecutive scans were obtained by two experienced operators. The same procedure was repeated within two weeks for the assessment of intersession variability. In all cases acceptable maps had at least 10.0mm of corneal coverage.All back elevation points were codified in order to facilitate statistical processing of data. Further to single point analysis, three additional parameters were evaluated: a) zone 4 parameter (z4) which derived by the analysis of all points at the central 4.0mm diameter zone, b) zone 8 parameter (z8) which derived by the analysis of all points at the central 8.0mm diameter zone, and, c) highest elevation point parameter (HEP), which derived by the analysis of the highest elevation points for all participants. Reproducibility of measurements was evaluated by means of intraclass correlation coefficients (ICC). Three different ICC types were calculated: a) intrasession ICC for both operators (ICC1 & ICC2), b) interobserver ICC, and, c) intersession ICC. Moreover, Bland-Altman plots were used to evaluate the level of agreement between the two operators.

Interventions

The same surgical procedure was applied to all CXLG patients that included: Instillation of proparacaine hydrochloride 0.5% drops for topical anaesthesia, application of a sponge saturated with 10% alcohol to the central cornea for 20-30 seconds and subsequent de-epithelialization by means of a hockey knife. Following de-epithelialization, a mixture of 0.1% riboflavin in 20% Dextran solution was instilled to the cornea for 30 minutes (2 drops every 2 minutes) prior to the irradiation. In details, an 8.0mm diameter of central cornea was irradiated for 30 minutes by UVA light with a wavelength of 370nm and an irradiance of 3mW/cm2.The UVA radiation source that was used is the UV-XTM (IROC AG, Zurich, Switzerland). Instillation of riboflavin drops (1 drop every 2 minutes) was continued during irradiation, as well.

Sponsors

Democritus University of Thrace
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Progressive keratoconus (Keratoconus group) * Corneal collagen cross linking (CxL) treatment at least one year prior to enrollment (CxL group)

Exclusion criteria

* Glaucoma * Suspicion of glaucoma * history of herpetic keratitis * corneal scarring * severe eye dryness * pregnancy or nursing * current corneal infection * underlying autoimmune disease

Design outcomes

Primary

MeasureTime frameDescription
Variability of posterior corneal surface elevation measurements within and between sessions and within and between observers.2 weeksThe Pentacam Classic (Oculus Optikgerate GmbH, Heidelberg, Germany, software version 1.14r04) was used for the sake of the study. Three consecutive scans were obtained by two experienced operators for the assessment of intrasession and interobserver variability. The same procedure was repeated within two weeks for the assessment of intersession variability.Bland-Altman plots were used to evaluate agreement between the 2 operators. The reproducibility of all measurements was evaluated by means of the intraclass correlation coefficient(ICC).

Countries

Greece

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026