Evaluation of the Ambu ® aScope® for Tracheal Intubation in Difficult Airways

Evaluation of the Ambu ® aScope® for Tracheal Intubation During Cervical Spine Immobilization With a Cervical Collar, in Comparison With a Conventional Reusable Fiberscope.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01467739
Enrollment
100
Registered
2011-11-09
Start date
2011-06-30
Completion date
2011-11-30
Last updated
2013-12-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endotracheal Intubation, Surgical Intervention

Brief summary

The purpose of this study is to evaluate a disposable fiberscope (Ambu ® aScope®) for tracheal intubation in difficult airways due to cervical immobilization by a cervical collar, and compare it to a conventional reusable fiberscope.

Detailed description

Any general anesthesia requiring tracheal intubation for controlled ventilation includes the likelihood of intubation failure and, in case of difficult or impossible mask ventilation, can be life-threatening. In patients with diagnosed or suspected disease of the cervical spine, airway control can be tricky. Indeed, the cervical collar used to secure the cervical spine makes direct laryngoscopy impossible. In elective surgery, the most commonly used technique is fiberoptic intubation, achievable without removing of the cervical collar. A new disposable fiberscope was recently developed by Ambu ®: the aScope®. It consists of a disposable flexible fiberscopic device, whose distal end is fitted with a camera that can be directed. This device is connected to a separate reusable LCD display. The aScope® is used as a conventional flexible fiberscope to guide the instrumentation of the airway. With the exception of case reports, all studies of this device in difficult conditions were performed on mannequins. The investigators propose to assess and validate this device on real patients with difficult airways caused by a rigid cervical collar and compare intubation conditions and time to the gold standard technique, the classical reusable fiberscope. Induction of general anesthesia is performed by the anesthesiologist responsible for the patient, according to the standards in the anesthesiology department. The cervical collar is fitted and positioned once the patient is asleep in addition to a dedicated oropharyngeal cannula (Ovassapian fiberoptic intubating airway cannula) in order to guide the aScope® or fiberscope in the oropharynx. The timer is activated once the investigating physician takes the aScope® or fiberscope in his hands. The device is advanced into the airway with visual control on the LCD screen for the aScope® or on an external dedicated screen for the fiberscope. Once in the trachea, the device will serve as a guide for introduction of the orotracheal tube, according to standard fiberscopic intubation technique. Tracheal intubation is confirmed through visualization of the distal end of the tube into the trachea, the onset of an end tidal CO2 curve and auscultation. The timer will be stopped at the onset of the end tidal CO2 curve.

Interventions

DEVICEAmbu ® aScope®
DEVICEa conventional reusable fiberscope

Sponsors

University of Lausanne Hospitals
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients older than 16 years * ASA 1-2 * BMI \< 35 kg/m2 * Surgery requiring general anesthesia with intubation of the trachea

Exclusion criteria

* Emergency operation * Patient ASA 3 or more * BMI above 35 kg/m2 * History of difficult airways * History of surgery or radiotherapy in head and neck * Presence of gastro esophageal reflux

Design outcomes

Primary

MeasureTime frameDescription
Effectiveness of the Ambu ® aScope® for tracheal intubation in difficult airways.Time to reach the carina and Time to obtain an end tidal CO2 curve by aScope in comparison to conventional reusable fiberscope.

Countries

Switzerland