Skip to content

Tapentadol Versus Oxycodone - a Mechanism-based Treatment Approach in Neuropathic Pain

Phase 4 Study of Tapentadol vs Oxycodone in Neuropathic Pain

Status
Terminated
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01458015
Enrollment
3
Registered
2011-10-24
Start date
2011-10-31
Completion date
2013-11-30
Last updated
2025-01-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Peripheral Neuropathy

Keywords

QST (quantitative sensory testing), neuropathic pain, tapentadol pr, oxycodone

Brief summary

The purpose of this study is to elucidate whether the additional mechanism of analgesia, i.e. reuptake inhibition of norepinephrine, of tapentadol leads to a change in different pain signs and symptoms in comparison to oxycodone.

Interventions

DRUGtapentadol, oxycodone

tapentadol pr 100-500 mg oxycodone cr 20-120mg

Sponsors

University Hospital Schleswig-Holstein
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* thermal or mechanical hyperalgesia * chronic neuropathic pain (NRS =\> 6)

Exclusion criteria

* non-specific

Design outcomes

Primary

MeasureTime frameDescription
Pain Upon Numeric Rating Scaleday 0 (baseline) and day 78 (V6; 10 weeks)Change of pain upon Numeric Rating Scale (NRS; 0 = no pain at all; 10 = maximum pain imaginable) from V1 to V6
Mechanical Pain Threshold (MPT)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Mechanical Pain Threshold from baseline to V6 The mechanical pain threshold (MPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Heat Pain Threshold (HPT)day 0 (baseline) and day 78 (10 weeks)Change of Heat Pain Threshold from V1 to V6 The was Heat Pain Threshold (HPT)measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Wind-Up Ratio (WUR)day 0 (baseline) and day 78 (10 weeks)Change of Wind-Up Ratio from V1 to V6 The Wind-Up Ratio (WUR) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Cold Pain Threshold (CPT)day 0 (baseline) and day 78 (10 weeks)Change of Cold Pain Threshold from baseline to V6 The Cold Pain Threshold (CPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Pressure Pain Threshold (PPT)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Pressure Pain Threshold from V1 to V6 The Pressure Pain Threshold (PPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Mechanical Pain Sensitivity (MPS)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Mechanical Pain Sensitivity from V1 to V6 The Mechanical Pain Sensitivity (MPS) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.
Dynamic Mechanical Allodynia (DMA)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Dynamic Mechanical Allodynia from V1 to V6 The Dynamic Mechanical Allodynia (DMA) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). Subjects were asked to give a pain rating for each stimulus on a '0-100' numerical rating scale ('0' indicating no pain, and '100' indicating most intense pain imaginable). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. A lower score indicates an improvement.

Secondary

MeasureTime frameDescription
Warmth Detection Threshold (WDT)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Warmth Detection Threshold from V1 to V6 The Warmth Detection Threshold (WDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.
Thermal Sensory Limen (TSL)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Thermal Sensory Limen from V1 to V6 The Thermal Sensory Limen (TSL) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically trasnformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.
Mechanical Detection Threshold (MDT)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Mechanical Detection Threshold from V1 to V6 The Mechanical Detection Threshold (MDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.
Vibration Detection Threshold (VDT)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Vibration Detection Threshold from V1 to V6 The Vibration Detection Threshold (VDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.
Paradoxical Heat Sensations (PHS)day 0 (baseline) and day 78 (V6; 10 weeks)Change of Number of Paradoxical Heat Sensations from V1 to V6 The number of Paradoxical Heat Sensations (PHS) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. An occurence of up to three paradoxical heat sensations was possible. The number was assessed. A lower number indicates an improvement.
Cold Detection Threshold (CDT)day 0 (baseline) and day 78 (10 weeks)Change of Cold Detection Threshold from V1 to V6 The Cold Detection Threshold (CDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Countries

Germany

Participant flow

Participants by arm

ArmCount
Oxycodone
tapentadol, oxycodone: tapentadol pr 100-500 mg oxycodone cr 20-120mg
1
Tapentadol
tapentadol, oxycodone: tapentadol pr 100-500 mg oxycodone cr 20-120mg
2
Total3

Baseline characteristics

CharacteristicOxycodoneTapentadolTotal
Age, Categorical
<=18 years
0 Participants0 Participants0 Participants
Age, Categorical
>=65 years
0 Participants0 Participants0 Participants
Age, Categorical
Between 18 and 65 years
1 Participants2 Participants3 Participants
Age, Continuous57 years52 years53.6 years
Race/Ethnicity, Customized
caucasian/european
1 Participants2 Participants3 Participants
Region of Enrollment
Germany
1 participants2 participants3 participants
Sex: Female, Male
Female
1 Participants1 Participants2 Participants
Sex: Female, Male
Male
0 Participants1 Participants1 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
2 / 21 / 1
serious
Total, serious adverse events
0 / 20 / 1

Outcome results

Primary

Cold Pain Threshold (CPT)

Change of Cold Pain Threshold from baseline to V6 The Cold Pain Threshold (CPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (10 weeks)

Population: Due to low recruitement numbers only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneCold Pain Threshold (CPT)V10.35 Z-score
OxycodoneCold Pain Threshold (CPT)V60.35 Z-score
TapentadolCold Pain Threshold (CPT)V1-1.1 Z-score
Primary

Dynamic Mechanical Allodynia (DMA)

Change of Dynamic Mechanical Allodynia from V1 to V6 The Dynamic Mechanical Allodynia (DMA) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). Subjects were asked to give a pain rating for each stimulus on a '0-100' numerical rating scale ('0' indicating no pain, and '100' indicating most intense pain imaginable). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. A lower score indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneDynamic Mechanical Allodynia (DMA)V141 score on a scale
OxycodoneDynamic Mechanical Allodynia (DMA)V62 score on a scale
TapentadolDynamic Mechanical Allodynia (DMA)V144 score on a scale
TapentadolDynamic Mechanical Allodynia (DMA)V65 score on a scale
Primary

Heat Pain Threshold (HPT)

Change of Heat Pain Threshold from V1 to V6 The was Heat Pain Threshold (HPT)measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneHeat Pain Threshold (HPT)V6-1.4 Z-score
OxycodoneHeat Pain Threshold (HPT)V1-0.5 Z-score
TapentadolHeat Pain Threshold (HPT)V1-0.2 Z-score
Primary

Mechanical Pain Sensitivity (MPS)

Change of Mechanical Pain Sensitivity from V1 to V6 The Mechanical Pain Sensitivity (MPS) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneMechanical Pain Sensitivity (MPS)V12.2 Z-score
OxycodoneMechanical Pain Sensitivity (MPS)V6-0.4 Z-score
TapentadolMechanical Pain Sensitivity (MPS)V12 Z-score
TapentadolMechanical Pain Sensitivity (MPS)V61.5 Z-score
Primary

Mechanical Pain Threshold (MPT)

Change of Mechanical Pain Threshold from baseline to V6 The mechanical pain threshold (MPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneMechanical Pain Threshold (MPT)V11.1 Z-score
TapentadolMechanical Pain Threshold (MPT)V12.6 Z-score
TapentadolMechanical Pain Threshold (MPT)V60.55 Z-score
Primary

Pain Upon Numeric Rating Scale

Change of pain upon Numeric Rating Scale (NRS; 0 = no pain at all; 10 = maximum pain imaginable) from V1 to V6

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

ArmMeasureGroupValue (MEAN)
OxycodonePain Upon Numeric Rating ScaleV63 score on a scale
OxycodonePain Upon Numeric Rating ScaleV16 score on a scale
TapentadolPain Upon Numeric Rating ScaleV19.5 score on a scale
TapentadolPain Upon Numeric Rating ScaleV65.5 score on a scale
Primary

Pressure Pain Threshold (PPT)

Change of Pressure Pain Threshold from V1 to V6 The Pressure Pain Threshold (PPT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodonePressure Pain Threshold (PPT)V10 Z-score
TapentadolPressure Pain Threshold (PPT)V11.65 Z-score
TapentadolPressure Pain Threshold (PPT)V60.9 Z-score
Primary

Wind-Up Ratio (WUR)

Change of Wind-Up Ratio from V1 to V6 The Wind-Up Ratio (WUR) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.) A lower z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneWind-Up Ratio (WUR)V1-0.6 Z-score
OxycodoneWind-Up Ratio (WUR)V60.75 Z-score
TapentadolWind-Up Ratio (WUR)V1-0.2 Z-score
Secondary

Cold Detection Threshold (CDT)

Change of Cold Detection Threshold from V1 to V6 The Cold Detection Threshold (CDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (10 weeks)

Population: Due to low number of participants only descriptive data can be provided.

ArmMeasureGroupValue (MEAN)
OxycodoneCold Detection Threshold (CDT)V1-1.2 Z-score
OxycodoneCold Detection Threshold (CDT)V6-1.45 Z-score
TapentadolCold Detection Threshold (CDT)V1-2.3 Z-score
Secondary

Mechanical Detection Threshold (MDT)

Change of Mechanical Detection Threshold from V1 to V6 The Mechanical Detection Threshold (MDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically transformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneMechanical Detection Threshold (MDT)V1-2.2 Z-score
TapentadolMechanical Detection Threshold (MDT)V1-0.1 Z-score
TapentadolMechanical Detection Threshold (MDT)V6-1 Z-score
Secondary

Paradoxical Heat Sensations (PHS)

Change of Number of Paradoxical Heat Sensations from V1 to V6 The number of Paradoxical Heat Sensations (PHS) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. An occurence of up to three paradoxical heat sensations was possible. The number was assessed. A lower number indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneParadoxical Heat Sensations (PHS)V10 sensations out of 3
TapentadolParadoxical Heat Sensations (PHS)V10.5 sensations out of 3
TapentadolParadoxical Heat Sensations (PHS)V60 sensations out of 3
Secondary

Thermal Sensory Limen (TSL)

Change of Thermal Sensory Limen from V1 to V6 The Thermal Sensory Limen (TSL) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Logarithmically trasnformed raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneThermal Sensory Limen (TSL)V1-2.1 Z-score
TapentadolThermal Sensory Limen (TSL)V6-2.45 Z-score
TapentadolThermal Sensory Limen (TSL)V1-1.9 Z-score
Secondary

Vibration Detection Threshold (VDT)

Change of Vibration Detection Threshold from V1 to V6 The Vibration Detection Threshold (VDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneVibration Detection Threshold (VDT)V1-1.8 Z-score
TapentadolVibration Detection Threshold (VDT)V1-1.85 Z-score
TapentadolVibration Detection Threshold (VDT)V6-1.72 Z-score
Secondary

Warmth Detection Threshold (WDT)

Change of Warmth Detection Threshold from V1 to V6 The Warmth Detection Threshold (WDT) was measured according to the established protocol of Deutscher Forschungsverbund Neuropathischer Schmerz (DFNS). See Rolke, R et al. Quantitative sensory testing in the German Research Network on Neuropathic Pain (DFNS): standardized protocol and reference values. Pain vol. 123,3 (2006): 231. Raw data were z-transformed by subtracting the mean value of the corresponding reference group followed by a division the respective standard deviation. If the resulting z-value exceeds 1.96, it is outside the 95% confidence interval of the standard normal distribution with zero mean and unit variance, independent of the original units of measurement. (also see Rolke et. al.). A higher z-value indicates an improvement.

Time frame: day 0 (baseline) and day 78 (V6; 10 weeks)

Population: Due to low number of participants only descriptive data is available

ArmMeasureGroupValue (MEAN)
OxycodoneWarmth Detection Threshold (WDT)V1-2 Z-score
TapentadolWarmth Detection Threshold (WDT)V1-1.05 Z-score
TapentadolWarmth Detection Threshold (WDT)V6-2 Z-score

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026