Skip to content

Routine Use of Sensor-Augmented Pump Therapy - a Follow up Study

Routine Use of Sensor-Augmented Pump Therapy - a Follow up Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01451372
Enrollment
69
Registered
2011-10-13
Start date
2011-06-30
Completion date
2011-12-31
Last updated
2019-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes

Keywords

Diabetes, CGM, CSII

Brief summary

The aim of this study is to document the routine practice in continuous glucose monitoring (CGM) in patients treated with sensor-augmented pump therapy and to assess clinical outcome (HbA1c) before the start of the sensor use to the end of the follow-up period. Moreover, data on treatment satisfaction, and fear of hypoglycemia, cost of the therapy, side effects and treatment interruption will be collected.

Detailed description

The most advanced technologies for the treatment of type 1 diabetes mellitus (T1DM) include insulin pumps for continuous subcutaneous insulin infusion (CSII) and glucose sensors allowing continuous glucose monitoring(CGM). Randomized controlled trials have shown that access to CGM can improve control in poorly-controlled patients regardless of insulin treatment therapy via reduced hyper- and hypoglycaemic excursions and improved mean HbA1c value. The Medtronic personal CGM device is composed of a glucose sensor linked to a MiniLink REAL-Time Transmitter, which transmits data from the glucose sensor to the insulin pump. The integration of these two technologies (CSII and personal CGM) into one system is called sensor-augmented pump therapy (SAP).The devices are CE-marked and routinely used in clinical practice in the Swedish market. Based on the clinical evidences provided, the Swedish Dental and Pharmaceutical Benefits Agency (TLV) concluded that the personal CGM when used in combination to a Medtronic insulin pump as SAP should be included in the Swedish reimbursement system. However the decision was upon specific patient indications: Patients with two or more severe hypoglycemias/year that require help from another person or Patients with HbA1c of at least 9%, in cases where optimized insulin therapy has not been effective or Children taking at least 10 medically required plasma glucose tests (fingersticks) per 24 hours and that certain follow-up information has to be complemented and submitted to TLV before March 1st, 2012. TLV requires follow-up information on T1 diabetes patients using SAP in Swedish clinical practice and based on the following outcome parameters: HbA1c-level of the patients Quality of life with use of CGM Side effects and therapy interruptions. Use and costs of the therapy Frequency of hypoglycemia Therefore, this project will observe the routine practice of personal CGM utilization in combination to Medtronic insulin pumps in T1DM patients in Sweden in approximately 15 investigational centers. The aim of this project is to reflect the daily practice in personal CGM therapy (sensor and MiniLink REAL-Time Transmitter) usage in diabetes patients treated with Medtronic insulin pumps in Sweden. Data on the HbA1c value before and up to six months use of personal CGM will be collected and information on the outcomes requested by TLV will be included in the study. The patient reported outcomes will be supplemented with patient preference data and will be estimated with a willingness-to-pay (WTP) approach.

Interventions

None listed

Sponsors

Medtronic Diabetes
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
No minimum to 69 Years
Healthy volunteers
No

Inclusion criteria

* Patient (and/or legal representative) has signed Patient Informed Consent(PIC) AND * Patient (0-69 years) was diagnosed with Type 1 DM and has been on insulin pump therapy (without any additional insulin injection) for at least 3 months prior to signature of the PIC AND * HbA1c ≥ 7 %) or * has experienced at least 2 severe hypoglycemic events in the last 12 months or * is performing on average more than 10 SMBG per day AND The patient has used, or is using or will start using continuous glucose monitoring as part of the CSII therapy for at least 70% of the time for a minimum of 3 months.

Exclusion criteria

* Participation in any other clinical trial - currently and/or in the last 3 months prior signature of informed consent and/or during the retrospective period of data collection. * Unwillingness to perform at least 4 BG tests per day * Unwillingness to maintain contact with HCP * For children: no reliable contact person * PREGNANT woman and wish of pregnancy * Vision and hearing impairment not allowing pump use * Any disease or drug treatment that can interfere with the outcome of sensor usage.

Design outcomes

Primary

MeasureTime frameDescription
Daily Usage of Blood Glucose Test (BG Testing)24 monthsDaily usage of blood glucose test 0-24 months after CGM usage. This information is collected in a journal questionnaire

Secondary

MeasureTime frameDescription
Frequency of Sensor Usage Per Month24 monthsFrequency of sensor usage per month during the study. This information is collected in a journal questionnaire

Countries

Sweden

Participant flow

Participants by arm

ArmCount
Type 1 Diabetes Subjects Using CGM
Type 1 Diabetes Subjects using CGM in Sweden
69
Total69

Baseline characteristics

CharacteristicType 1 Diabetes Subjects Using CGM
Age, Customized
Age, Continuous
33 years
Region of Enrollment
Sweden
69 participants
Sex: Female, Male
Female
47 Participants
Sex: Female, Male
Male
22 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
18 / 69
other
Total, other adverse events
18 / 69
serious
Total, serious adverse events
0 / 69

Outcome results

Primary

Daily Usage of Blood Glucose Test (BG Testing)

Daily usage of blood glucose test 0-24 months after CGM usage. This information is collected in a journal questionnaire

Time frame: 24 months

Population: journal questionnaires about blood glucose testing were collected from 65 out of 69 subjects

ArmMeasureValue (MEAN)Dispersion
Type 1 Diabetes Subjects Using CGMDaily Usage of Blood Glucose Test (BG Testing)4.35 number of blood glucose test per dayStandard Deviation 2.4
Secondary

Frequency of Sensor Usage Per Month

Frequency of sensor usage per month during the study. This information is collected in a journal questionnaire

Time frame: 24 months

Population: Journal questionnaires about sensor usage were collected from 61 out of 69 subjects

ArmMeasureValue (MEAN)Dispersion
Type 1 Diabetes Subjects Using CGMFrequency of Sensor Usage Per Month4 number of sensor used per monthStandard Deviation 1.5

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026