Skip to content

New Fabric Attenuation Device in Endovascular Interventional Radiology (PREFER)

Prospective Randomized Evaluation of a New Fabric Attenuation Device in Endovascular Interventional Radiology (PREFER)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01450969
Acronym
PREFER
Enrollment
60
Registered
2011-10-13
Start date
2011-09-30
Completion date
2011-12-31
Last updated
2014-09-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Exposure

Keywords

Operator Comfort Assessment, Radiation protection, Measurement of Radiation Exposure, Endovascular Interventional Radiology

Brief summary

The PREFER Trial primary objective of the trial is to show how much radiation attenuation is provided by XPF in absolute and relative terms.

Detailed description

The PREFER Trial has three main objectives. The primary objective of the trial is to show how much radiation attenuation is provided by XPF in absolute and relative terms. The secondary objective of the study is to measure and compare the amount of radiation that interventional radiologists are exposed to per case in an interventional suite setting using FDA approved XPF thyroid collars or standard 0.5 mm Pb equivalent thyroid collars. The third objective is to assess the operator comfort wearing the XPF protection devices. In order to achieve these objectives, measurements will be performed in 60 consecutive endovascular procedures requiring C-arm fluoroscopy performed at BCVI. Participants will be asked to wear an XPF cap (weighing approximately 100 grams) in every study procedure. Furthermore, a prospective randomization will be performed, assigning participants to wear their own standard 0.5 mm Pb equivalent thyroid collar or to wear the FDA approved XPF thyroid collar. Radiation exposure will be monitored with 4 radiation detectors (TLDs, 2 attached to the cap, 2 attached to the collar) which the participant is required to wear. After each procedure the participant will be asked to rate the comfort of wearing the devices on a scale from 1 to 100.

Interventions

None listed

Sponsors

Baptist Health South Florida
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Interventional Radiologists practicing in Baptist Cardiac & Vascular Institute * consecutive endovascular procedure requiring C-arm fluoroscopy

Exclusion criteria

* Interventional Neuroradiologists and Interventional Cardiologists will not be included in this study.

Design outcomes

Primary

MeasureTime frameDescription
Radiation attenuation in percentage (%) and in absolute terms (μSv/min)The attenuation is assessed directly after each procedure (day 1)The null hypothesis is that the XPF thyroid collar is inferior to the standard 0.5mm Pb lead equivalent thyroid collar with regard to radiation attenuation/transmission. The alternative hypothesis is that the XPF thyroid collar is non-inferior to the standard thyroid collar. If there is truly no difference between standard and XPF thyroid collars, then 60 patients are required to be 95% sure that the lower limit of a one-sided 95% confidence interval (or equivalently a 90% two-sided confidence interval) will be above the non-inferiority limit of -0.7% transmission rate and -0.013 μSv/min.

Secondary

MeasureTime frame
Wearing comfort of the XPF cap and collar on a scale from 0-100.(day 1) Operators are asked directly after each procedure to rate the wearing comfort

Countries

United States

Outcome results

None listed