Skip to content

Prospective Evaluation of Strontium in Patients After CardioGen-82 PET MPI Scanning at Two Clinical Sites

A Prospective Study to Estimate Inadvertent Radiation Exposure From Strontium Isotopes in Patients Who Have Undergone CardioGen-82® PET MPI Scanning at Two Clinical Sites

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01430975
Enrollment
72
Registered
2011-09-09
Start date
2011-09-30
Completion date
2012-03-31
Last updated
2012-04-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Radiation Exposure

Keywords

Radiation Exposure, Rubidium 82, Strontium 82, Strontium 85

Brief summary

This study is to be performed at two clinical sites where patients received CardioGen-82 during the time period January to June, 2011 and where patients were scanned chronologically near to the index patients (2 days before or after). Of these, it is planned that at least 30 patients will be entered in this trial. Index patient is the term applied to individuals who had radiation spectra indicative of Sr-82 and Sr-85 detected by hand-held survey meters.

Detailed description

This clinical study protocol will use a three tier approach consisting of the following examinations: * Patient examination with Survey Meter: The patient will first be tested at the clinical sites using a survey meter. In those patients whose radiation count is ≥ 2 times above background count using a standard survey meter, the presence of Sr-82 and/or Sr-85 will be assessed through a quantitative reading from a calibrated portable isotope identifier. * Patient examination with Portable Isotope Identifier: This examination will be done by use of a portable isotope identifier, which will be supplied by the Sponsor to the study sites. An assessor, independent to the study site and will perform the examination. In those patients whose radiation count is ≥ 2 times above background count using a standard survey meter, the presence of Sr-82 and/or Sr-85 will be assessed through a quantitative reading from a calibrated portable isotope identifier. The reading will be forwarded along with the date of the reading, the date of the patient's CardioGen-82® scan, and the total dose of CardioGen-82® administered to the patient, to an independent medical expert, independent to the study site, who will back-calculate an estimated dose of Sr-82 and/or Sr-85 from these data. * Patient examination at Oak Ridge National Laboratory: Any patient whose estimated dose of Sr-82 exceeds the specified limit of 0.02 microcuries per mCi Rb-82 administered, and/or whose estimated dose of Sr-85 exceeds the specified limit of 0.2 microcuries per mCi Rb-82 administered, will be asked to travel to Oak Ridge National Laboratory in Tennessee, for accurate whole body scanning. Scan data from Oak Ridge National Laboratories will be analyzed by one or more independent medical experts to accurately back-calculate exposure to Sr-82 and/or Sr-85, and to estimate health hazard for the patient.

Interventions

CardioGen-82 was not administered as part of this trial but the patients enrolled had to have received CardioGen-82 previously

Sponsors

Bracco Diagnostics, Inc
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Male or female; * Gave informed consent to participate in the study; * Received CardioGen-82 that has been eluted from the generator in close proximity (2 days before or after) the index patients.

Exclusion criteria

-Any patient previously enrolled in and completed this study.

Design outcomes

Primary

MeasureTime frameDescription
Determination of radiation exposure from Sr-82 and/or Sr-85on average within 24 hoursTo determine radiation exposure from Sr-82 and/or Sr-85 in patients administered CardioGen-82® for PET MPI at the two sites reporting Sr-82/Sr-85 breakthrough
Determination of extent of SR-82/Sr-85 exposure, if positive exposure is detectedwithin 2 weeksTo determine the extent of the Sr-82/Sr-85 exposure, in the subset of patients with positive testing exceeding the specified threshold for the breakthrough of Sr-82/Sr-85, by performing whole body scanning at Oak Ridge National Laboratory for eventual health hazard assessment

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026