Skip to content

Clinical Outcome of Birmingham Hip Resurfacing (BHR) Using VISIONAIRE Femoral Alignment Guide

Prospective, Multi- Site, Clinical Study of Clinical Outcomes Following Hip Resurfacing Using VISIONAIRE Femoral Alignment Guide

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01427361
Acronym
BHR
Enrollment
25
Registered
2011-09-01
Start date
2009-10-31
Completion date
2011-08-31
Last updated
2018-03-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteoarthritis

Brief summary

The primary objective of this study is to investigate the accuracy of the femoral implant placement utilizing the VISIONAIRE Femoral Alignment Guide in Birmingham Hip Resurfacing (BHR) surgery postoperatively after total hip resurfacing using the BHR System.

Detailed description

This is a prospective, multi- site, clinical study of clinical outcomes following hip resurfacing using VISIONAIRE Femoral Alignment Guide. The objective of this study is to evaluate the safety and efficacy of the blocks and to assess alignment of the BHR system when using VISIONAIRE Femoral Alignment Guide. This study will also document any device-related surgical complications or adverse radiographic observations.

Interventions

None listed

Sponsors

Smith & Nephew, Inc.
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

1. Males or females, at least 21 years of age, inclusive, and skeletally mature. 2. Patient diagnosed with osteoarthritis of the hip requiring primary total hip resurfacing due to: * Non-inflammatory arthritis (degenerative joint disease) such as osteoarthritis, traumatic arthritis, avascular necrosis, or dysplasia/DDH, or * Inflammatory arthritis such as rheumatoid arthritis. 3. Patient is willing to consent to participate in the study 4. Patient is in stable health and is free of or treated and stabilized for cardiac, pulmonary, hematological, or other conditions that would pose excessive operative risk. 5. Patient meets medical clearance to have surgery required for this study

Exclusion criteria

1. Patient with infection or sepsis. 2. Patient with any vascular insufficiency, muscular atrophy, or neuromuscular disease severe enough to compromise implant stability or postoperative recovery. 3. Patient is pregnant or plans to become pregnant during the course of the study. 4. Patient known to have insufficient bone stock to support the BHR device including: * Subjects with severe osteopenia should not receive a BHR procedure. Patients with a family history of severe osteoporosis or severe osteopenia. * Subjects with osteonecrosis or avascular necrosis (AVN) with \>50% involvement of the femoral head (regardless of FICAT Grade) should not receive a BHR. * Subjects with multiple cysts of the femoral head (\>1cm) should not receive a BHR. * Note: In cases of questionable bone stock, a DEXA scan may be necessary to assess inadequate bone stock. 5. Patient has known moderate to severe renal insufficiency. Subjects on medications (such as high-dose or chronic aminoglycoside treatment) or with co-morbidities (such as diabetes) that increase the risk of future, significant renal impairment should be advised of the possibility of increase in systemic metal ion concentration. 6. Patient has a known sensitivity to materials in the device. 7. Patient is immuno-suppressed. 8. Patient has physical, emotional or neurological conditions that would compromise the patient's compliance with postoperative rehabilitation and follow-up. 9. Patient has BMI \>40.

Design outcomes

Primary

MeasureTime frameDescription
Investigate the accuracy of the femoral implant placement utilizing the VISIONAIRE Femoral Alignment Guide in BHR surgery postoperatively after total hip resurfacing using the BHR System6 weekRadiographic evaluation of postoperative femoral stem angle.

Secondary

MeasureTime frameDescription
Number of Participants with Adverse Events as a Measure of Safety and Tolerability6 week and 6 monthSurgical and device related adverse events or revision

Countries

Canada

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026