Skip to content

Metal on Metal Versus Metal on Highly Crossed Linked Polyethylene Sytem

A Randomized Multicentre Clinical Trial Comparing The Metal on Metal Hip System Versus The Metal on Highly Crossed Linked Polyethylene System

Status
Terminated
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01422564
Acronym
MOM
Enrollment
41
Registered
2011-08-24
Start date
2007-01-31
Completion date
2010-12-31
Last updated
2015-05-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ankylosing Spondylitis, Avascular Necrosis, Congenital Dysplasia of the Hip, Injury of Hip and Thigh, Osteoarthritis, Post-traumatic; Arthrosis, Rheumatoid Arthritis

Brief summary

This trial will evaluate the 36mm or greater metal head on metal hip system and compare it to the 32mm or 28mm metal head on polyethylene (liner) hip system in patients receiving a primary cementless total hip replacement.

Interventions

DEVICEMetal on Metal Hip System

Total hip arthroplasty with a metal on metal component system

DEVICEHighly Cross Linked Polyethylene cup System

Total hip arthroplasty with Highly Cross Linked Polyethylene cup System

Sponsors

University Health Network, Toronto
CollaboratorOTHER
Nova Scotia Health Authority
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Male and non-pregnant female subjects 65 years of age or older * Subjects undergoing cementless hip arthroplasty. If a press fit metal articulation acetabulum is not possible; the modular cup system will be utilized with screw fixation and a metal head of the greatest diameter deemed appropriate and safe for the patient will be utilized.(At the discretion of the surgeon). The cup in this situation may have a metal or poly articulation. The patient will be followed as an intent to treat (the patient will be evaluated and included in the group as randomized) * Subjects with, but not limited to, original diagnoses of osteoarthritis, avascular necrosis, rheumatoid arthritis, congenital dysplasia of the hip, ankylosing spondylitis, posttraumatic arthritis, and traumatic injury to the hip joint. * Subjects who are able and willing to understand the conditions of informed consent, to participate in the study according to the protocol for the length of the expected term of follow-up, and to follow their physician's directions.

Exclusion criteria

* Subjects undergoing hip arthroplasty using a cemented femoral component and/or a bipolar prosthesis. * Subjects with gross obesity, \>45% over ideal body weight for age and height. Refer to Appendix A, Obesity Table. * Subjects with active infections. * Subjects with malignancy in the area of the involved hip joint. * Subjects with a neuromuscular deficit that interferes with the subject's ability to limit weight bearing or places an extreme load on the implant during the healing period. * Subjects with a diagnosis of Fibromyalgia * Female subjects who are pregnant or may be pregnant. * Subjects whom, as judged by the surgeon, are not capable of understanding the informed consent or the requirements of the protocol, or are reasonably unlikely to be compliant with the prescribed postoperative routine and the follow-up evaluation schedule. * Subjects who have a known sensitivity to device materials.

Design outcomes

Primary

MeasureTime frame
Revision Rate4 years

Secondary

MeasureTime frameDescription
Harris Hip Scoreimmediate post-op, 6 months, 1 year, 2 years, 4 years
Dislocation Rate4 years
Wear and osteolysis5-15 years
Gait Analysis6 months and 1 year post-opUsing the Walkabout portable gait monitor
Metal Ions4 years
Complication Rate4 yearsAll complications

Outcome results

None listed