Skip to content

Efficacy of Cricoid Pressure in Occluding the Esophageal Entrance: A Glidescope ® Study

Efficacy of Cricoid Pressure in Occluding the Esophageal Entrance: A Glidescope ® Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01415661
Acronym
CP
Enrollment
89
Registered
2011-08-12
Start date
2011-01-31
Completion date
2011-09-30
Last updated
2012-04-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aspiration

Brief summary

This investigation was designed to assess the patency of the esophageal entrance during cricoid pressure (CP) in anesthetized, paralyzed obese and non obese patients using the Glidescope ® video laryngoscope (GVL).

Detailed description

Eighty-nine patients undergoing surgeries necessitating general anesthesia and tracheal intubation were enrolled in this study. Group 1 (OB) including obese patients (n= 59) was undergoing bariatric surgery. Following rapid sequence induction/intubation (RSII) anesthesia with cricoid pressure, clear view of the vocals cord and the entrance to the esophagus were assessed using Glidescope® video laryngoscope before intubation and following intubation. Following securing the airway, efficacy of cricoid pressure was tested by the capability to insert gastric tubes (20 and 38 Fr) under direct vision using GVL. Group 2 (NOB) including non-obese patients (n=30) was undergoing moderate surgery requiring tracheal intubation under general anesthesia. Efficacy of cricoid pressure was also tested similarly using GT's (20 and 38 Fr) following induction of anesthesia and before intubation. Inability of GT insertion was recorded as non-patent esophagus (effective CP) and successful insertion of GT was recorded as patent esophagus (ineffective CP). Then CP was released and insertion of GT achieved for correct verification of the esophageal opening position in both groups.

Interventions

The current study test by direct visual evidence the occlusion of esophageal entrance during application CP. The closure of the lumen was further demonstrated by the inability to introduce a GT into the esophagus during CP.

Sponsors

Procare Riaya Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Obese patients ( BMI 40-70 kg/m2) * No Contre indication to cricoid pressure * No-obese patients (BMI \< 40)

Exclusion criteria

* ASA 3 and 4 * Contre indication to cricoid pressure

Design outcomes

Primary

MeasureTime frame
Efficacy of Cricoid Pressure for Prevention of Aspiration24 hours

Countries

Saudi Arabia

Outcome results

None listed