Annular Array Ultrasound in Ophthalmology

High-frequency-ultrasound Annular Arrays for Ophthalmic Imaging

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01415037
Enrollment
30
Registered
2011-08-11
Start date
2011-10-31
Completion date
2016-12-31
Last updated
2019-01-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetic Retinopathy, Posterior Vitreous Detachment

Keywords

Annular Array Ultrasound, Ultrasound Exam, Posterior Vitreous Detachment, PVD, Diabetic Retinopathy

Brief summary

The objective of this research is to improve the care of ocular disease and disorders, in particular the changes in the eye associated with diabetes, by providing clinicians with dramatically improved ultrasonic images of the entire eye. The research combines advanced high-frequency, high-resolution ultrasonic annular arrays transducers with new processing techniques designed to overcome several limits that have been reached with conventional high frequency ultrasound systems. The investigators propose that diagnosis of eye diseases using annular arrays can be more effective than the conventional ultrasound images by at least 50%; i.e., that for every 2 posterior vitreous detachments detected conventionally, 3 will be detected with the annular arrays.

Detailed description

The goal of this study is to develop and evaluate advanced annular-array transducer technology for rapid, high-definition imaging. The study will assess high frequency ultrasound (HFU, 40 & 20 MegaHertz) annular arrays in imaging posterior vitreous detachments (PVDs) associated with diabetic retinopathy, the leading cause of blindness in the US working-age population according to Prevent Blindness America. Current HFU instruments do not use linear arrays for such applications because of a variety of technical and cost reasons. Instead, current HFU instruments use mechanically scanned, single-element transducers, which provide fine-resolution images over a very limited depth of field (DOF). For ophthalmic applications, a shallow DOF causes most ocular anatomy to be imaged with poor definition compared to the in-focus region; therefore, because only a small portion of the eye is in focus at a given time, detection and assessment of ocular conditions such as PVD are prone to inaccuracies and false-negative determinations. Annular-array transducers offer a promising approach to significantly extend DOF and to increase the depth range over which fine-lateral resolution is provided. The investigators will validate system performance using animal experiments and human-subject examinations. First, in vivo animal experiments will be conducted to evaluate a 40-MegaHertz (MHz) annular array for anterior-segment imaging and a 20-MHz annular array for posterior segment and full-globe imaging. The investigators will test the hypothesis that 20-MHz annular arrays improve detection of PVD. Validation of this hypothesis will significantly improve our ability to assess disease status in diabetic retinopathy.

Interventions

PROCEDUREannular array ultrasound exam

For this research study you will be asked to sit in a chair. You will be given 2 drops of a numbing solution. The ultrasound camera will be enclosed in a sterile membrane and will be placed gently upon your eye. You may be asked to gaze at a light source while measurements are being made. The procedure will last about 10-15 minutes from start to finish.

Sponsors

Riverside Research Institute
CollaboratorOTHER
National Eye Institute (NEI)
CollaboratorNIH
Columbia University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
60 Years to 90 Years
Healthy volunteers
Yes

Inclusion criteria

* over age 60 * people with diabetic retinopathy or posterior vitreous detachments

Exclusion criteria

* under age 60

Design outcomes

Primary

MeasureTime frameDescription
Change in detection of posterior vitreous detachment: 20MHz annular array versus 10MHz single elementSubjects will be examined with both the 20MHz annular array and 10MHz single element ultrasound during the same exam, approximately 30 minutes in duration.The investigators will examine eyes with both conventional 10MHz ultrasound and a 20MHz annular array with synthetic focusing. The investigators will evaluate and compare images acquired with both techniques and determine their relative efficacy in visualizing the presence or absence of posterior vitreous detachment.

Countries

United States

Outcome results

None listed