Skip to content

Effect of Wide Pulse Pressure on the Predictability of Stroke Volume Variation for Fluid Responsiveness in Patients Undergoing Off-pump Coronary Artery Bypass Graft

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01404455
Enrollment
66
Registered
2011-07-28
Start date
2010-12-31
Completion date
2011-08-31
Last updated
2012-01-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Stroke Volume Variation

Brief summary

The investigators examined the predictability of stroke volume variation for fluid responsiveness in patients with wide pulse pressure undergoing off-pump coronary artery bypass graft

Interventions

OTHERHES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading

HES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading during 15 minutes after induction of anesthesia

Sponsors

Severance Hospital
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SCREENING
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 1\. Age ≥ 20 * 2\. elective off-pump coronary artery bypass graft

Exclusion criteria

* 1\. arrhythmia * 2.EF \<40% * 3.valvular heart dz * 4.pul HTN * 5.PAOD * 6.lung dz * 7.NYHA IV * 8.ESRD

Design outcomes

Primary

MeasureTime frame
The predictability of stroke volume variation for fluid responsiveness in patients with wide pulse pressure30 min

Secondary

MeasureTime frame
Cut off value of stroke volume variation for predicting fluid responsiveness in patients with wide pulse pressure30 min

Countries

South Korea

Outcome results

None listed