Skip to content

Effect of a Pre Heparin Coated Dialysis Filter on Coagulation During Hemodialysis

The Effect of a Heparin-coated Dialysis Filter (Evodial) on Clotting and Intravascular Coagulation During Hemodialysis (HD) When Compared to a Conventional Polyflux Filter (170H)

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01388270
Enrollment
12
Registered
2011-07-06
Start date
2011-09-30
Completion date
2016-01-31
Last updated
2016-02-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Renal Failure

Keywords

Hemodialysis, Anticoagulation, Clotting, Coagulation, dalteparin, Clotting in the extracorporeal system during HD, Antithrombogenic property of Evodial HD filter, Anticoagulation during HD

Brief summary

The purpose of this study is to determine whether the heparin-coated dialysis filter is superior to a conventional filter during hemodialysis in twelve stable, chronic hemodialysis (HD) patients. The antithrombogenic properties of the heparin-coated dialysis filter and of the conventional filter will be compared by means of statistical tests.

Detailed description

In the present study twelve chronic hemodialysis (HD) patients will be included. Exclusion criteria are use of acetylsalicylic acid and/warfarin, clinical signs of infection and disseminated malignant disease. For each patient four HD sessions will be investigated; alternating with use of the pre-heparin-coated filter or the conventional filter. Dalteparin is reduced to 50% of the conventional dose and is given as one single bolus dose at start of HD. The venous drip chamber will be visually inspected for evaluation of clot score during each HD session. The filter will be visually inspected for clot score at the end of each session. Blood specimens will be drawn systematically during each HD session to evaluate platelet and coagulation activity as well as anti Factor Xa activity, haematology and urea/creatinine to evaluate dialysis effect. The antithrombogenic properties of the pre-heparin-coated filter and the conventional filter will be compared by means of statistical tests. The hypothesis is that the pre-heparin-coated filter induces significantly less clot score in the extracorporeal system during hemodialysis and also significantly less intravascular activation of the coagulation system compared to the conventional filter.

Interventions

DEVICEa pre-heparin-coated hemodialysis filter; Hepran

Use of the pre-heparin-coated filter compared to the conventional filter in a cross over design

Sponsors

Oslo University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Stable HD patients of at least 18 years of age. * HD treatment for at least one month. * Dialysis time at least 4 hours three times per week. * Stable Hemoglobin value of at least 11 g/dl during the last 4 weeks.

Exclusion criteria

* Use of warfarin and/or acetylsalicylic acid. * Disseminated malignant disease. * Clinical signs of infection.

Design outcomes

Primary

MeasureTime frameDescription
Activation of the intravascular coagulation system during hemodialysis with use of a pre-heparin-coated filter compared to a conventional filterActivation of the intravascular coagulation system is assessed during four dialysis sessions within a two weeks period for a single patientBlood specimens for analysis of prothrombin fragment 1+2 and beta-thromboglobulin will be drawn at start of hemodialysis and after three and four hours of all hemodialysis sessions.

Secondary

MeasureTime frameDescription
A secondary outcome measure is degree of clot score in the extracorporeal system during hemodialysis with use of a pre-heparin-coated filter compared to the conventional filter.The degree of clot score in the extracorporeal system is assessed during four hemodialysis sessions that for a single patient take place within a time frame of two weeksDegree of clot score will be evaluated in the venous drip chamber as follows: 1=normal (no signs of clot). 2=fibrinous ring, 3=clot and 4=stop in dialysis due to high degree of clotting

Countries

Norway

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026