Ultrasonography in Confirming Proper Position of Endotracheal Tube

Ultrasonography in Confirming Proper Position of Endotracheal Tube in Emergency Department at Siriraj Hospital: Applicability and Accuracy

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01373437
Enrollment
80
Registered
2011-06-15
Start date
2010-09-30
Completion date
2010-12-31
Last updated
2011-06-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Endotracheal Tube Wrongly Placed During Anesthetic Procedure

Keywords

Ultrasonography, US, Confirming, Confirmation, Proper, Position, Endotracheal tube, ETT, Emergency department, ED, Applicability, Accuracy

Brief summary

The purpose of this study is to assess the applicability of using ultrasonography in confirmation of the position of the endotracheal tube (ETT) after intubated to patients.

Detailed description

To assess the applicability of using ultrasonography as compared to routine portable CXR in confirmation of ETT position. To determine the accuracy of ultrasonography in measuring the depth of ETT as compare to standard CXR method.

Interventions

DEVICEUltrasonography (Sonosite )

Sonosite MICROMAXXTM with linear probe L38e/10-5 MHz

Sponsors

Mahidol University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* age \>18 years old with either endotracheal or nasotracheal intubation * having normal airway anatomy * performed portable CXR after intubation

Exclusion criteria

* presence in history of neck radiation, cervical spine immobility/instability * unstable vital signs * unwilling to participate or denial of informed consent

Design outcomes

Primary

MeasureTime frameDescription
The confirmation of ETT depth1 hourA transcricothyroid membrane view of the ultrasonography was chosen for confirmation of ETT depth measurement. Firstly, measured the distance from probe (skin) to anterior surface of ETT. Then, measured the distance from probe (skin) to balloon cuff level. Finally the depth of ETT (Distance from vocal cord to balloon cuff) was calculated by using Pythagorus rule.

Secondary

MeasureTime frameDescription
The confirming the presence of ETT in airway.1 hourA transcricothyroid membrane view was chosen for confirmation of ETT position. Various glottic structures such as True Vocal Cord (TVC), False Vocal Cord (FVC), and arythenoid cartilage can be visualized.

Countries

Thailand

Outcome results

None listed