Cervical Spine Biomechanics During Endotracheal Intubation

Intubation Mechanics of the Stable and Unstable Cervical Spine

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01369381
Enrollment
14
Registered
2011-06-08
Start date
2011-12-31
Completion date
2012-07-31
Last updated
2012-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Other Biomechanical Lesions of Cervical Region, Spinal Diseases, Tracheal Intubation Morbidity

Keywords

Cervical spine, Endotracheal intubation, Laryngoscope, Biomechanics

Brief summary

Current methods for endotracheal intubation in the presence of cervical spine (c-spine) instability are not evidence-based. This is so because the relationships between the forces applied during intubation (by the laryngoscope) and the resulting c-spine movement have not yet been quantitatively characterized. As a result, with the current level of knowledge, it is not known, and it is not possible to predict, which types of c-spine instability have the greatest risk of cervical spinal cord injury with intubation. This shortcoming makes it impossible to know which intubation devices and techniques are likely to be safest in the presence of c-spine instability. To address this critical lack of knowledge, the overarching purpose of the proposed research is to: 1) quantitatively relate c-spine movement that results from the forces applied to the peri-airway tissues during intubation (force-motion relationships), and 2) use these data to develop a mathematical model of the c-spine that will predict which types of c-spine instability result in the greatest amount of abnormal c-spine motion and associated spinal cord compression during intubation. This clinical study will utilize laryngoscope blades that are instrumented with a high resolution pressure mapping system to make high-resolution measurements of the forces and pressures of intubation while making simultaneous measurements of c-spine motion. In this study, study subjects will be intubated using both a conventional (Macintosh) laryngoscope and an alternative (Airtraq) laryngoscope. By using two different laryngoscopes, we, the investigators, will introduce forces of differing magnitudes and distributions to peri-airway tissues. The Airtraq does not require a direct line of sight to visualize the vocal cords, and among the various new alternative laryngoscopes it is the only one that has been shown to result in 30-50% less cervical motion than a conventional (Macintosh) laryngoscope. Accordingly, we hypothesize 1) 30-50% less force will be applied with the Airtraq laryngoscope than with the conventional (Macintosh) laryngoscope and 2) 30-50% less c-spine motion will occur with the Airtraq. By studying (intubating) each subject twice, any differences in the c-spine force-motion relationships between devices will be due to the devices themselves. By studying each subject twice, we can account for (and eliminate) differences among study subjects in c-spine biomechanical properties.

Interventions

PROCEDUREEndotracheal intubation

Study patients undergo endotracheal intubation using both a conventional direct laryngoscope (Macintosh) and an alternative indirect laryngoscope (Airtraq). The order of intubation (Macintosh then Airtraq--or--Airtraq then Macintosh) is randomized.

Sponsors

National Institute for Biomedical Imaging and Bioengineering (NIBIB)
CollaboratorNIH
Colorado State University
CollaboratorOTHER
University of Iowa
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
BASIC_SCIENCE
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* Patient Height: 5-feet, 0-inches to 6-feet, 0-inches * Patient body mass index: less than 30 kg/m2 * Planned surgery requires use of C-arm fluoroscopy * Planned surgery to take place at University of Iowa and requires general anesthesia and orotracheal intubation

Exclusion criteria

* The patient is a prisoner * The patient is pregnant * The patient is not competent to personally give consent * Neurological signs and symptoms indicating cervical spinal cord myelopathy * Cervical spine images demonstrating anatomic instability, traumatic injury, significant cervical stenosis, and/or spinal immobility * Condition associated with cervical spine anatomic abnormalities such as Rheumatoid arthritis, Down Syndrome, Ankylosing spondylitis, Osteogenesis imperfecta * Prior cervical spine surgery of any type * History of difficult endotracheal intubation * Currently symptomatic gastroesophageal reflux disease * Currently symptomatic asthma or other reactive airway disease * Any history of coronary artery disease * Any history of cerebral aneurysm(s) * History of vocal cord and/or glottic disease or dysfunction * Contraindication to receiving 100% oxygen * Systolic blood pressure greater than 180 mmHg * Diastolic blood pressure greater than 100 mmHg * American Society of Anesthesiologists Physical Status class of 4, 5, or 6 * Known allergy or other adverse response to study drugs: midazolam, lidocaine, fentanyl, propofol \[eggs, soy beans\], rocuronium, or sevoflurane. * Mallampati oropharyngeal class of III or IV * Thyromental distance less than 6.0 cm * Sternomental distance less than 12.5 cm * Maxillary incisors loss or in poor condition

Design outcomes

Primary

MeasureTime frameDescription
Cervical spine segmental intervertebral motionData collection takes place during two sequential endotracheal intubations (40-45 seconds), with follow-up assessments on postoperative days 1, 3, and 7.Lateral fluoroscopy is used to measure cervical spine motion during endotracheal intubation.

Secondary

MeasureTime frameDescription
Laryngoscope blade force distributionData collection takes place during two sequential endotracheal intubations (40-45 seconds), with follow-up assessments on postoperative days 1, 3, and 7.Pressure-mat technology is used to measure spacially distributed forces applied by the laryngoscope blade during endotracheal intubation.
Glottic visualizationData collection takes place during two sequential endotracheal intubations (40-45 seconds), with follow-up assessments on postoperative days 1, 3, and 7.An image of the glottis during intubation is obtained for off-line measurement of the percentage of glottic opening as seen by the laryngoscopist.

Countries

United States

Outcome results

None listed