Skip to content

Measuring Blood Pressure in the Lung Circulation With Sonar Technology (Echo-Doppler)

Detection, Estimation and Characterization of Pulmonary Blood Pressure by Transthoracic Parametric Doppler (TPD)

Status
Terminated
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01357746
Enrollment
60
Registered
2011-05-23
Start date
2011-07-31
Completion date
Unknown
Last updated
2013-08-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pulmonary Arterial Hypertension

Keywords

Pulmonary arterial blood pressure doppler

Brief summary

This is a non-invasive study using a standard doppler echocardiographic transducer which records signals emanating from the lungs (TPD). These signals are caused by pulsation of blood vessels in the lung tissue. The innovations in this study are: 1. The software processing of the reflected ultra-sound waves from the lung rendering a reproducible, clear and strong signal in sync with the cardiac cycle, 2. The observation based on pilot studies that blowing hard against resistance during recording (something called a Valsalva maneuver), affects the lung signal weakening it and even obliterating it as the pressure rises. The investigators hypothesis is that since the signal comes from the blood vessels in the lung, the pressure at which the recorded signal disappears during the Valsalva maneuver represents the blood pressure in the lungs.

Detailed description

Current methods for noninvasive measurement of pulmonary arterial blood pressure by standard echo-doppler equipment are fraught with uncertainty. So much so that patients being screened and followed for pulmonary arterial hypertension require right heart catheterization. An invasive and uncomfortable and potentially dangerous procedure. This study is designed to confirm our preliminary observation that there is good correlation between Valsalva maneuver pressure and pulmonary arterial blood pressure. Sixty patients undergoing right heart catheterization for clinical reasons will be studied. The study itself is short, about 30 minutes, painless and done with the patient either sitting up in bed or semi-reclining. The probe is positioned over the right chest wall and the patient is requested to successively blow into a mouthpiece at rising pressures, to tolerance. The results obtained using TPD to asses pulmonary arterial pressure will be compared to the results obtained at catheterization. This is part of the development phase of the technology.

Interventions

PROCEDURETransthoracic pulmonary doppler recording

A 30 min recording of doppler signals from the right chest wall including measurements while the patient performs Valsalva maneuvers

Sponsors

Echosense Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Eligibility * Age 18 years or older * Patients who are clinically suspected of having elevated pulmonary blood pressure , due to cardiac or cardio-pulmonary disease preferably any one or more of the conditions listed below, and due to have right heart catheterization as part of the diagnostic work-up: * Patients with CHF * Patients with primary pulmonary arterial hypertension * Patients with COPD * Patients with asthma * Patients with interstitial lung disease * Patients with sarcoidosis * Signed informed consent.

Exclusion criteria

* Patients unable to cooperate. * Inability to assume a sitting or supine position * Patients with severe chest wall deformity

Design outcomes

Primary

MeasureTime frameDescription
Reaching target enrollment number1-2 yearsEnrollment of 60 valid patients

Secondary

MeasureTime frameDescription
Lack of adverse effects1-2 yearsNo adverse effects are expected but since this is a new application of old technolology safety is a possible issue.