Clinical Evaluation of the Sorin Group's REPLY MR-conditional Pacing System

Clinical Evaluation of the Sorin Group's REPLY MR-conditional Pacing System

Status
Withdrawn
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01341522
Enrollment
0
Registered
2011-04-25
Start date
2012-01-31
Completion date
2013-05-31
Last updated
2013-07-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dual-chamber Pacemaker Placement

Brief summary

Permanent cardiac pacemakers have represented a contraindication to Magnetic Resonance Imaging (MRI). Strong static, gradient and radiofrequency fields used for MRI are thought to be detrimental to pacemaker function and possibly cause harm to patients undergoing MRI examinations. A previous study has shown that MRI is indicated in 17% of all patients with pacemakers within 12 months of device placement , which demonstrates the need of practical, safe approach for performing MRI on pacemaker patients. A new Reply MR-conditional pacing system is developed by Sorin Group for safe use in the MRI environment. The new pacing system is composed by the Reply pacemaker and the Filtrea bradycardia pacing leads. This study intends to demonstrate the safety and the efficacy in the MRI environment of the Sorin Group Reply MR-conditional pacing system.

Interventions

PROCEDUREMRI exam

MRI exam

PROCEDUREcontrol

waiting room

Sponsors

LivaNova
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients who are candidates for dual-chamber pacemaker primo-implantation * Patients who have indication for implantation of a dual-chamber pacemaker according to the American College of Cardiology and the American Heart Association * Patients who are able and willing to undergo elective MRI scanning * Patients who are scheduled for implant of a Reply DR pacemaker and Filtrea lead(s) only * Patients who provided signed and dated informed consent

Exclusion criteria

* Non MR-compatible device or material implant * Chronic atrial fibrillation (for atrial lead evaluation) * Incessant ventricular tachyarrhythmia (for ventricular lead evaluation) * Inability to understand the purpose of the study or refusal to co-operate * Unavailability for scheduled follow-ups at the implanting centre * Already included in another clinical study that could affect the results of this study * Inability or refusal to provide informed consent * Patient is minor (less than 18-year old) * Patient is pregnant (women of childbearing potential should have a negative pregnancy test prior to enrolment); * Patient has life expectancy of less than 1 year * Patient is forfeiture of freedom or under guardianship * Any patient to whom a contra-indication from device and lead labeling applies

Design outcomes

Primary

MeasureTime frame
assess the pacing system-, MRI- and implant procedure-related complication-free rate1 month
assess atrial and ventricular lead-related complication-free rate3 months
compare the changes in atrial and ventricular pacing thresholds before and after MRI, between MRI and control groups3 months
compare the changes in atrial and ventricular sense amplitude after MRI between MRI and control groups3 months

Secondary

MeasureTime frame
Summarize atrial and ventricular electrical performances3 months
Summarize atrial and ventricular lead handling2 weeks
Summarize all implant procedure, pacing system- and MRI procedure-related adverse events12 months

Outcome results

None listed