Skip to content

Trial Comparing Kaffes Stent With Plastic Prosthesis in the Treatment of Anastomotic Biliary Strictures Post Orthotopic Liver Transplantation

Randomized Controlled Trial Comparing Kaffes Stent With Plastic Prosthesis in the Treatment of Anastomotic Biliary Strictures Post Orthotopic Liver Transplantation

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01339078
Enrollment
5
Registered
2011-04-20
Start date
2011-09-30
Completion date
2015-12-31
Last updated
2022-12-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Biliary Strictures Post Liver Transplantation

Keywords

Biliary strictures, liver transplantation

Brief summary

Biliary anastomotic strictures (post liver transplantation) occur in 15-20 % of the cases. Biliary stenting using plastic prosthesis during a period of 1 year is the treatment of choice. Problematic in this approach is the regular change, necessary to overcome occlusion of the stent, resulting in cholestasis and/or infection. This change needs to be performed every 3 months or more frequently in patients with symptoms of stent occlusion. The Kaffes stent (RMS) is a metallic removable stent, especially constructed for the treatment of biliary anastomotic strictures post liver transplantation. The advantage could be that this stent is less prone to occlusion with a lower change frequency (e.g. every 6 months). No randomized, controlled trial (RCT) or data exist comparing plastic stenting versus Kaffes stenting.

Interventions

The patients receive plastic stenting after ortothopic liver transplantation with a choledocho-choledochal anastomosis, presenting with an anastomotic stricture. These patients will receive change of the stent every 3 months, for a total duration of 1 year.

PROCEDUREKaffes stenting

The patients receive Kaffes stenting after ortothopic liver transplantation with a choledocho-choledochal anastomosis, presenting with an anastomotic stricture. These patients will receive change of the stent every 6 months, for a total duration of 1 year.

Sponsors

University Hospital, Ghent
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients after orthotopic liver transplantation with a choledocho- choledochal anastomosis, presenting with an anastomotic stricture * diagnosis established by : * elevated liver tests * a narrowing of the anastomosis on Magnetic resonance cholangiopancreatography (MRCP): with or without intrahepatic bile duct dilatation * no acute or chronic rejection * no Cytomegalovirus (CMV) infection * no other possible causes of elevated liver tests * confirmation of the stricture needs to be confirmed during the diagnostic endoscopic retrograde cholangiopancreatography (ERCP) procedure immediately before the therapeutic procedure.

Exclusion criteria

* non-anastomotic strictures * absence of informed consent * Roux-en-Y construction * Living related liver transplantation patients.

Design outcomes

Primary

MeasureTime frameDescription
Comparison of patency of the bile duct between normal and Kaffes stenting.after 6 months and after 1 yearComparison of patency of the bile duct 6 months after 1 year of stenting. Patency is defined as the presence of normal liver function test (direct bilirubin, aspartate aminotransferase (AST), alanine aminotransferase (ALT), gamma glutamyl transpeptidase (gamma-GT), alkaline phosphatase) and non-dilated bile ducts on Magnetic resonance cholangiopancreatography (MRCP). In the presence of cytomegalovirus (CMV) infection, rejection or other causes of possible disturbed liver function parameters, the MRCP findings rule over the lab tests.

Secondary

MeasureTime frameDescription
safety of the Kaffes stentduring a period of 1 yearThe safety of the Kaffes stent, compared to the normal stent will be assessed (e.g. change of stents, blood tests, endoscopic retrograde cholangio-pancreatography (ERCP)).
Duration of hospitalizationduring a period of 1 year
Number of stent changesduring a period of 1 yearPatients included in the plastic stenting arm will receive change of stents every 3 months for a total duration of 1 year. Patients included in the Kaffes stent arm will receive change of the stent every 6 months for a total duration of 1 year. In case the patient develops symptoms of stent occlusion (rise of liver tests, fever, septicimiae), the stent will be changed as soon as possible.
Comparison of costs between normal stenting and Kaffes stenting.during a period of 1 yearComparison of costs over a period of 1 year between normal stenting and Kaffes stenting will be evaluated.

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026