Skip to content

Hepatocyte Matrix Implant Study Indonesia

Intracorporeal Autologous Hepatocyte Matrix Implant: A New Tissue Engineering Procedure for Treatment of Hepatic Disease

Status
UNKNOWN
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01335568
Acronym
HMIIndo
Enrollment
10
Registered
2011-04-14
Start date
2011-04-30
Completion date
2012-12-31
Last updated
2011-04-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Liver Disease, Liver Cirrhosis, Liver Insufficiency

Keywords

Hepatocyte, Scaffold, Matrix, Liver cirrhosis, Liver insufficiency

Brief summary

This clinical investigation of the hepatocyte matrix implant is an evaluation blinded non-randomized and monocentric pilot study of Phase I, which is conducted as a therapeutic investigation. Randomization is not possible due to ethical and practical reasons. This study has already been approved in Switzerland and has been adapted to Indonesian Law and disease. This new treatment procedure has already been successfully used on the basis of compassionate use in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.

Detailed description

This new treatment procedure has already been successfully used on the basis of individual treatment in Germany. The hepatocyte matrix implant is a new patented procedure consisting of bio-matrix technology. A formaldehyde-free special matrix consisting of self-dissolving polymers is applied as a carrier substance and is cultivated with human autologous cells using a special technique. Clinically the bio artificial liver replacement tissue for patients with end-stage hepatic disease has been developed as a first application. In this procedure autologous hepatocytic tissue and pancreatic tissue is removed (liver resection and pancreatic biopsy) from the patient in a first surgical procedure. The tissue is sent to a specialized Cell Culture Laboratory. The laboratory is GMP certified for this procedure. The cells are processed according to SOPs in a special perfusion procedure and prepared on several platelets of matrices (platelets of 20 mm diameter and 4mm thickness). After completion of the laboratory process the bio tissues are implanted into the mesentery of the small intestine during a second operation. The cells are growing controlled on the matrix, take on the capillaries of the patient and thus connect to the blood circulation. The implanted cells multiply by a specific factor and independently take over the metabolic function of the original liver after two to four weeks. In the following process the carrier matrix dissolves completely and implanted cells develop into liver cell tissue.

Interventions

PROCEDUREHepatocyte Matrix Implant

Open surgical procedure with biopsy of liver tissue and pancreatic tissue for proceeding in institutional GMP laboratory. Implantation of autologous hepatocytes and islet cells on scaffolds into the small bowel mesentery. Usually 10 to 20 implants are used.

Sponsors

Baermed
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* endstage liver disease * stable and non-improving liver condition for at least 3 month * alcoholic liver cirrhosis: proven alcohol abstinence for 6 month or more * patient in bad general condition

Exclusion criteria

* pregnancy * drug addiction (except alcohol) * psychiatric disease * HIV positive * sepsis * peritoneal carcinosis * hereditary liver disease * acute liver failure

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of clinical and laboratory parameters of liver function6 monthsEvaluation of clinical parameters MELD, CHILD, Asictes, portal hypertension in comparison of values measured 3 and 6 months before operation Evaluation of laboratory parameters Bilirubin, ASAT, ALAT, alkaline phosphatase, cholinesterase, albumin, total protein

Countries

Indonesia

Contacts

Primary ContactSuryadi The, Dr, MD
sury4d1md@gmail.com+62 8129204193
Backup ContactHans U Baer, Prof MD
hans.baer@baermed.ch+41 387 30 70

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 17, 2026