Effect of Rapid Transfusion With Fluid Management System (FMS) on Plasma Potassium in Liver Transplantation Recipients

Potassium Change in the Fluid Management System (FMS) Reservoir and Its Effect on the Plasma Potassium Concentration During Liver Transplantation Surgery

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01331889
Enrollment
10
Registered
2011-04-08
Start date
2011-10-31
Completion date
2016-04-30
Last updated
2016-07-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Condition Requiring Rapid Transfusion During Liver Transplantation Surgery

Keywords

transfusion, liver transplantation, potassium

Brief summary

Rapid infusion of red blood cells is known to result in hyperkalemia in the body. However, potassium concentration in the blood mixture (usually made of RBC, FFP and normal saline) in the reservoir of rapid infusion system and its effect on the plasma potassium change during rapid transfusion are unknown. This study is designed to investigate these changes while massive transfusion is performed during liver transplantation surgery.

Interventions

None listed

Sponsors

Seoul National University
CollaboratorOTHER
Seoul National University Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* preoperative anemia (hemoglobin \< 10 g/dl) * preoperative coagulopathy

Exclusion criteria

* children under age 18 * low risk of intraoperative bleeding

Design outcomes

Primary

MeasureTime frameDescription
potassium concentration in the Fluid Management System (FMS) reservoirafter transfusion of 150 ml of blood mixtureDuring bolus transfusion (300ml) of blood mixture, blood sample is taken from the side port of infusion line of Fluid Management System (FMS) when 150 ml of blood mixture was transfused. Because the priming volume of the internal circuit is approximately 100 ml, blood sample that was taken after 150 ml transfusion represents the content in the reservoir.

Secondary

MeasureTime frameDescription
plasma potassium of the patientbefore and after transfuison of 300 ml of blood mixtureJust before transfusion starts, blood samples are taken from the central venous catheter and arterial line at the same time to measure baseline values. At the immediate end of transfusion, blood samples are taken again from the same sites to measure the resultant changes.