Skip to content

Diagnosis of Acute Rejection in Renal Transplant Patients by Urine Mass Spectrometry

Non-invasive Diagnosis of Acute Rejection in Renal Transplant Patients Using Mass Spectrometry of Urine Samples - a Multicentre Diagnostic Phase III Trial

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01315067
Enrollment
600
Registered
2011-03-15
Start date
2011-10-31
Completion date
2017-06-15
Last updated
2017-08-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Rejection of Renal Transplant

Keywords

kidney transplantation, acute rejection, diagnosis, urine analysis, urinary peptides, mass spectrometry, allograft biopsy, pathology, diagnostic study

Brief summary

Reliable and timely detection of acute rejections in renal transplant patients is important to preserve the graft function and to prevent premature graft failure. The current gold standard for the rejection diagnosis is a renal biopsy which is usually performed upon an unexplained decline in the graft function (determined by serum creatinine or clearance). Because of the insensitivity of creatinine determinations and the invasiveness of renal biopsies, non-invasive tests have been suggested to diagnose acute rejection including mass spectrometry (MS) analysis of urine samples. The ability of MS analysis to detect acute rejection has been demonstrated in small studies on selected patients but evidence is lacking that this test is efficacious in the routine setting of the post-transplant patient care. Based on our previous work that established urine peptide sets for acute rejection by MS, a prospective, multicentre diagnostic phase III study will be executed. The aim of the study is to prove that this test is as equally effective as the allograft biopsy to detect acute rejection in patients that undergo a biopsy for unexplained renal dysfunction. The perspective of this approach is that the test could be used either in place of the biopsy or as decision guidance whether a biopsy is necessary to confirm the presence of rejection. Another perspective is that the MS test (respectively, a simplified test system derived from this method) could be used in the regular post-transplant surveillance for acute rejection, in place of the relatively insensitive procedure with periodic monitoring of the graft function by creatinine determinations.

Interventions

None listed

Sponsors

Hannover Medical School
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients with a kidney or combined kidney/pancreas transplantation * Unexplained renal allograft dysfunction within the first year of transplantation * Renal allograft biopsy, which is clinically indicated to verify or exclude an acute rejection

Exclusion criteria

* Lacking consent of the patient to participate in the study

Design outcomes

Primary

MeasureTime frameDescription
Ability of the urine mass spectrometry test to diagnose acute renal allograft rejection, compared to the gold standard 'allograft biopsy'Results of the urine test will be assessed in relation to the simultaneously performed allograft biopsy (1 day)In patients with unexplained renal allograft dysfunction who get an allograft biopsy to clarify if an acute rejection is present, a simultaneous urine sample will be taken. The peptide pattern of this urine sample is analyzed by mass spectrometry and a diagnosis is made (rejection present/not present) based on a pre-defined peptide pattern which was established to detect acute allograft rejection. In the primary outcome analysis, the sensitivity and specificity of the rejection diagnosis by the urine test is compared to the diagnosis made by the allograft biopsy.

Secondary

MeasureTime frameDescription
Sensitivity and specificity of the urine test to diagnose acute renal allograft rejection in subgroups with different severity grades of the rejectionResults of the urine test will be assessed in relation to the simultaneously performed allograft biopsy (1 day)Sensitivity/specificity measures for the urine test will be determined in subgroups of patients with different severity of the rejection. Severity grading is based on the pathomorphological classification of the rejection (according to the BANFF classification) and on the functional impairment of the allograft at the time of rejection diagnosis.
Sensitivity and specificity of the urine test to diagnose acute renal allograft rejection in subgroups with kidney transplantation alone and with combined pancreas/kidney transplantationResults of the urine test will be assessed in relation to the simultaneously performed allograft biopsy (1 day)Sensitivity/specificity measures for the urine test will be determined in subgroups of patients who have a kidney transplant or a combined pancreas/kidney transplant.
Sensitivity and specificity of the urine test to diagnose acute renal allograft rejection in subgroups with concurrent infectionResults of the urine test will be assessed in relation to the simultaneously performed allograft biopsy (1 day)Sensitivity/specificity measures for the urine test will be determined in subgroups of patients who have concurrent infections at the time of the biopsy and urine sampling such as cytomegaly virus, polyoma virus, and urinary tract infection. The analysis intends to identify potential interference of these conditions with the urine mass spectrometry test.

Countries

Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 15, 2026