Evaluation of the Feasibility a New Silicone Hydrogel Contact Lens

A Study to Evaluate the Product Feasibility of a New Silicone Hydrogel Contact Lens

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01309906
Enrollment
66
Registered
2011-03-07
Start date
2010-12-31
Completion date
2011-02-28
Last updated
2020-10-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Myopia

Brief summary

The objective of this study is to determine the clinical feasibility and to evaluate the product performance of an investigational contact lens.

Interventions

Bausch & Lomb investigational silicone hydrogel contact lens worn on a daily wear basis for 1 week.

Ciba Visions Air Optix Aqua contact lens, worn on a daily wear basis for 1 week.

Sponsors

Bausch & Lomb Incorporated
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
OTHER
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Have physiologically normal anterior segments not exhibiting clinically significant biomicroscopy findings. * Be myopic and require lens correction in each eye. * Be adapted wearers of soft contact lenses, wear a lens in each eye, and each lens must be of the same manufacture and brand.

Exclusion criteria

* Any systemic disease affecting ocular health. * Using any systemic or topical medications that will affect ocular physiology or lens performance. * An active ocular disease, any corneal infiltrative response or are using any ocular medications. * Any Present finding during the slit lamp examination that, in the Investigator's judgment, interferes with contact lens wear. * Allergic to any component in the study care products.

Design outcomes

Primary

MeasureTime frameDescription
Visual AcuityAt 1 week follow upVisual acuity was assessed by distance high contrast logarithm of the minimum angle of resolution (logMAR).

Secondary

MeasureTime frameDescription
Percentage of Eyes With > Grade 2 Slit Lamp FindingsAt 1 week follow upGraded slit lamp findings for each eye, including epithelial edema, epithelial microcysts, corneal staining, limbal and bulbar injections, upper lid tarsal conjunctival abnormalities, corneal neovascularization, and corneal infiltrates were graded for severity on a scale from 0 (No Finding) to 4 (Severe Finding). The outcome measure is any finding \> grade 2, across abnormalities.
Symptoms and ComplaintsAt 1 week follow upAt 1-Week Follow-up, subjects were asked to rate 16 common symptoms/complaints on a scale of 0 to 100, with 100 being the most favorable score.

Countries

United States

Participant flow

Recruitment details

A total of 66 participants (132 eyes) were enrolled in the study. One-half were randomized to receive the investigational lens, and the other half were randomized to receive the control lens. After one week of wearing the first lens type, the subjects returned for an exam and crossed over to the second lens type for one week.

Participants by arm

ArmCount
Overall
All participants received both treatment groups.
66
Total66

Baseline characteristics

CharacteristicOverall
Age, Continuous31.1 years
STANDARD_DEVIATION 9
Sex: Female, Male
Female
44 Participants
Sex: Female, Male
Male
22 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 660 / 66
serious
Total, serious adverse events
0 / 660 / 66

Outcome results

Primary

Visual Acuity

Visual acuity was assessed by distance high contrast logarithm of the minimum angle of resolution (logMAR).

Time frame: At 1 week follow up

Population: There were 65 subjects (130 eyes) in each group for this outcome measure.

ArmMeasureValue (LEAST_SQUARES_MEAN)Dispersion
Investigational LensVisual Acuity-0.038 logMARStandard Deviation 0.088
Air Optix Aqua LensVisual Acuity-0.040 logMARStandard Deviation 0.088
Secondary

Percentage of Eyes With > Grade 2 Slit Lamp Findings

Graded slit lamp findings for each eye, including epithelial edema, epithelial microcysts, corneal staining, limbal and bulbar injections, upper lid tarsal conjunctival abnormalities, corneal neovascularization, and corneal infiltrates were graded for severity on a scale from 0 (No Finding) to 4 (Severe Finding). The outcome measure is any finding \> grade 2, across abnormalities.

Time frame: At 1 week follow up

Population: There were 65 subjects (130 eyes) in each group for this outcome measure.

ArmMeasureValue (COUNT_OF_UNITS)
Investigational LensPercentage of Eyes With > Grade 2 Slit Lamp Findings0 eyes
Air Optix Aqua LensPercentage of Eyes With > Grade 2 Slit Lamp Findings0 eyes
Secondary

Symptoms and Complaints

At 1-Week Follow-up, subjects were asked to rate 16 common symptoms/complaints on a scale of 0 to 100, with 100 being the most favorable score.

Time frame: At 1 week follow up

Population: There were 65 subjects (130 eyes) in each group for this outcome measure.

ArmMeasureGroupValue (LEAST_SQUARES_MEAN)Dispersion
Investigational LensSymptoms and ComplaintsRedness92.1 score on a scaleStandard Deviation 11.3
Investigational LensSymptoms and ComplaintsBurning/stinging upon insertion89.7 score on a scaleStandard Deviation 16.7
Investigational LensSymptoms and ComplaintsVision upon insertion88.1 score on a scaleStandard Deviation 14.8
Investigational LensSymptoms and ComplaintsEase of handling/insertion86.3 score on a scaleStandard Deviation 17.8
Investigational LensSymptoms and ComplaintsVision88.3 score on a scaleStandard Deviation 14.8
Investigational LensSymptoms and ComplaintsOverall comfort85.7 score on a scaleStandard Deviation 18.4
Investigational LensSymptoms and ComplaintsVision in low light86.9 score on a scaleStandard Deviation 14.9
Investigational LensSymptoms and ComplaintsEase of handling/removal90.7 score on a scaleStandard Deviation 13
Investigational LensSymptoms and ComplaintsLens cleanness upon insertion91.6 score on a scaleStandard Deviation 12.2
Investigational LensSymptoms and ComplaintsDryness83.0 score on a scaleStandard Deviation 19.8
Investigational LensSymptoms and ComplaintsLens cleanness upon removal87.4 score on a scaleStandard Deviation 17.6
Investigational LensSymptoms and ComplaintsComfort upon insertion86.6 score on a scaleStandard Deviation 18.9
Investigational LensSymptoms and ComplaintsOverall impression83.9 score on a scaleStandard Deviation 19.4
Investigational LensSymptoms and ComplaintsItchiness90.2 score on a scaleStandard Deviation 16.2
Investigational LensSymptoms and ComplaintsLens cleanness87.9 score on a scaleStandard Deviation 17
Investigational LensSymptoms and ComplaintsComfort at end of day80.1 score on a scaleStandard Deviation 22.7
Air Optix Aqua LensSymptoms and ComplaintsLens cleanness89.6 score on a scaleStandard Deviation 17
Air Optix Aqua LensSymptoms and ComplaintsBurning/stinging upon insertion90.5 score on a scaleStandard Deviation 16.7
Air Optix Aqua LensSymptoms and ComplaintsComfort upon insertion86.9 score on a scaleStandard Deviation 18.9
Air Optix Aqua LensSymptoms and ComplaintsOverall comfort87.8 score on a scaleStandard Deviation 18.4
Air Optix Aqua LensSymptoms and ComplaintsComfort at end of day79.2 score on a scaleStandard Deviation 22.7
Air Optix Aqua LensSymptoms and ComplaintsEase of handling/insertion91.7 score on a scaleStandard Deviation 17.8
Air Optix Aqua LensSymptoms and ComplaintsDryness81.8 score on a scaleStandard Deviation 19.8
Air Optix Aqua LensSymptoms and ComplaintsItchiness90.4 score on a scaleStandard Deviation 16.2
Air Optix Aqua LensSymptoms and ComplaintsRedness93.1 score on a scaleStandard Deviation 11.3
Air Optix Aqua LensSymptoms and ComplaintsVision upon insertion92.7 score on a scaleStandard Deviation 14.8
Air Optix Aqua LensSymptoms and ComplaintsVision90.7 score on a scaleStandard Deviation 14.8
Air Optix Aqua LensSymptoms and ComplaintsVision in low light88.6 score on a scaleStandard Deviation 14.9
Air Optix Aqua LensSymptoms and ComplaintsLens cleanness upon insertion93.4 score on a scaleStandard Deviation 12.2
Air Optix Aqua LensSymptoms and ComplaintsLens cleanness upon removal89.5 score on a scaleStandard Deviation 17.6
Air Optix Aqua LensSymptoms and ComplaintsOverall impression84.5 score on a scaleStandard Deviation 19.4
Air Optix Aqua LensSymptoms and ComplaintsEase of handling/removal93.2 score on a scaleStandard Deviation 13

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026