Novel Non-Invasive Monitoring Parameter in a Hospital Setting

A Novel Cardio-Respiratory Parameter in a Hospital Setting

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01306201
Enrollment
63
Registered
2011-03-01
Start date
2011-02-28
Completion date
2012-03-31
Last updated
2014-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Respiratory Failure, Respiratory Insufficiency

Keywords

Hospital Setting

Brief summary

Data collected from this study will be used to evaluate the performance of a monitoring algorithm.

Detailed description

The goal of this study is to assess equivalency, performance, and accuracy of a new monitoring algorithm in a hospital setting.

Interventions

None listed

Sponsors

Medtronic - MITG
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subjects 18 years old or older 2. Written informed consent from the patient or their legally authorized representative before initiation of any study-related procedures 3. Subjects on general care floor

Exclusion criteria

1. Severe contact allergies to standard adhesive materials 2. Abnormalities that may prevent proper application of the device 3. Women who are pregnant or lactating 4. Subjects with significant arrhythmia

Design outcomes

Primary

MeasureTime frameDescription
The Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.Participants were monitored for average of 30 minutesMean and standard deviations of respiration rates collected from patients in the hospital settings were compared between Covidien Respiration Rate Software, Transthoracic Impedance and End-Tidal Carbon Dioxide Waveforms. Each patient served as its own control.

Secondary

MeasureTime frameDescription
The Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.Participants were monitored on average for 30 minutesThe data used for analysis consisted of multiple simultaneous measures of RR\_TTI, RR\_V1.0 and RR\_EtCO2 for each subject. Given N sets of simultaneous RR values for each of P patients, the simultaneous RR values were used to calculate a pair of RMSD values for each subject. The two RMSD values, RMSDRR\_V1.0\_vs\_EtCO2, and RMSDTTI\_vs\_EtCO2, quantify the mean absolute difference in simultaneous estimates of respiratory rate between RR\_V1.0 compared with RR\_EtCO2 and RR\_TTI compared with RR\_EtCO2, respectively for the subjects with 95% confidence of mean ± 3.38 BrPM. The Measure type is Number and represents the RMSD of Covidien Nellcor Respiration Rate Software

Countries

United States

Participant flow

Recruitment details

Recruitment dates were February 10, 2011- to March 4th,2011

Participants by arm

ArmCount
In-patient Volunteers
In-patients from the hospital who choose to participate in the study
63
Total63

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyArrhythmia4
Overall StudyFiles could not be processed3
Overall StudyFiles unreadable3

Baseline characteristics

CharacteristicIn-patient Volunteers
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
6 Participants
Age, Categorical
Between 18 and 65 years
57 Participants
Age, Continuous47 years
STANDARD_DEVIATION 15
Region of Enrollment
United States
63 participants
Sex: Female, Male
Female
40 Participants
Sex: Female, Male
Male
23 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
0 / 63
serious
Total, serious adverse events
0 / 63

Outcome results

Primary

The Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.

Mean and standard deviations of respiration rates collected from patients in the hospital settings were compared between Covidien Respiration Rate Software, Transthoracic Impedance and End-Tidal Carbon Dioxide Waveforms. Each patient served as its own control.

Time frame: Participants were monitored for average of 30 minutes

Population: 10 participants were excluded from data analysis due to following reasons: unreadable files,arrhythmia,electronic data files coud not be processed

ArmMeasureValue (MEAN)Dispersion
Respiration Rate From Covidien Respiration Rate SoftwareThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.15.4 BrPM (Breaths Per Minute)Standard Deviation 4
Respiration Rate From Endtidal Carbon Dioxide WaveformThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.16.0 BrPM (Breaths Per Minute)Standard Deviation 4.6
Respiration Rate From Transthoracic ImpedanceThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.16.8 BrPM (Breaths Per Minute)Standard Deviation 4.8
Secondary

The Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.

The data used for analysis consisted of multiple simultaneous measures of RR\_TTI, RR\_V1.0 and RR\_EtCO2 for each subject. Given N sets of simultaneous RR values for each of P patients, the simultaneous RR values were used to calculate a pair of RMSD values for each subject. The two RMSD values, RMSDRR\_V1.0\_vs\_EtCO2, and RMSDTTI\_vs\_EtCO2, quantify the mean absolute difference in simultaneous estimates of respiratory rate between RR\_V1.0 compared with RR\_EtCO2 and RR\_TTI compared with RR\_EtCO2, respectively for the subjects with 95% confidence of mean ± 3.38 BrPM. The Measure type is Number and represents the RMSD of Covidien Nellcor Respiration Rate Software

Time frame: Participants were monitored on average for 30 minutes

ArmMeasureValue (NUMBER)
Respiration Rate From Covidien Respiration Rate SoftwareThe Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.1.60 Breaths Per Minute (BrPM)
Post Hoc

Calculate Covidien Respiration Rate Software Accuracy as Mean Error +/- Standard Deviation.

Time frame: Overall average

ArmMeasureValue (MEAN)Dispersion
Respiration Rate From Covidien Respiration Rate SoftwareCalculate Covidien Respiration Rate Software Accuracy as Mean Error +/- Standard Deviation.0.07 Breaths Per Minute (BrPM)Standard Deviation 1.98