Skip to content

Pilot Study of the Safety and Efficacy of Anakinra (Recombinant Human Interleukin-1 Receptor Antagonist) in Heart Failure

Pilot Study of the Safety and Efficacy of Anakinra (Recombinant Human Interleukin-1 Receptor Antagonist) in Heart Failure

Status
Completed
Phases
Phase 1Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01300650
Enrollment
11
Registered
2011-02-21
Start date
2011-02-28
Completion date
2011-08-31
Last updated
2017-11-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Keywords

Heart failure, Inflammation, Interleukin-1, Cardiopulmonary exercise

Brief summary

This is an open-label, non-randomized, pilot-study to evaluate the effect of Interleukin-1 blockade on exercise capacity in patients with heart failure. Subjects will undergo cardiopulmonary exercise testing at baseline and after 2-weeks treatment with anakinra (recombinant human Interleukin-1 receptor antagonist).

Interventions

DRUGAnakinra

Anakinra 100 mg subcutaneous injection daily

Sponsors

National Institutes of Health (NIH)
CollaboratorNIH
National Center for Research Resources (NCRR)
CollaboratorNIH
Virginia Commonwealth University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Confirmed diagnosis of heart failure * Recent echocardiogram documenting left ventricular ejection fraction \<40% * High sensitivity C-reactive protein \>2 mg/L.

Exclusion criteria

* Recent changes (previous 3 months) in HF maintenance medications (beta-blockers, angiotensin converting enzyme \[ACE\] inhibitors, aldosterone antagonists, vasodilators, cardiac glycosides, diuretics) * Hospitalization for worsening HF or acute decompensated HF within the previous 12 months * Anticipated need for cardiac resynchronization therapy (CRT) or automated-implantable cardioverter defibrillator (AICD) * Angina or electrocardiograph (ECG) changes that limit maximum exertion during cardiopulmonary exercise testing or baseline ECG changes that limit the ability to detect ischemia (i.e. left bundle-branch block). * Recent (\<14 days) use of anti-inflammatory drugs (not including NSAIDs), chronic inflammatory disorder (including but not limited to rheumatoid arthritis, systemic lupus erythematosus), malignancy, active infection, or any comorbidity limiting survival or ability to complete the study * Severe kidney dysfunction (eGFR \<30 mL/min) * Coagulopathy (INR \>1.5), thrombocytopenia (\<50,000/mm3), or leukopenia (absolute neutrophil count \<1,500/mm3) * Pregnancy (female patients will be required to take a urine pregnancy test) * Latex or rubber allergy * Inability to give informed consent

Design outcomes

Primary

MeasureTime frameDescription
Median Interval Change From Baseline in Peak VO214 daysPeak VO2 is a measurement of oxygen consumption rate during exercise (milliliters of oxygen per minute). It is calculated by continuous measurement of oxygen consumed during exercise while patients breath through a mask/tube. To account for variability in patient size, the oxygen consumption is divided by patient body weight. The outcome measure time frame was 14 days. This means that change in peak VO2 was calculated as the difference between peak VO2 at baseline and 14 days. To calculate this change, we used the mathematical process of subtraction (change in peak VO2 = Peak VO2 \[day 14\] - Peak VO2 \[baseline\])
Median Interval Change From Baseline in the Minute Ventilation and Carbon Dioxide Production (VE/VCO2 Slope)14 daysThe VE/VCO2 slope is calculated as the ratio of minute ventilation (VE) and carbon dioxide production (VCO2). Because these measurements share the same units, the resultant ratio is unitless. Change in VE/VCO2 slope was calculated as the change in VE/VCO2 slope between baseline and 14 days. We therefore calculated the difference between VE/VCO2 slope measurements that occurred at baseline and at 14 days (change in VE/VCO2 slope = VE/VCO2 slope \[day 14\] - VE/VCO2 slope \[baseline\])

Secondary

MeasureTime frameDescription
Interval Change From Baseline in Heart Failure Symptoms as Measured by Duke Activity Status Index (DASI)14 daysThe Duke Activity Status Index (DASI) is a scale that quantifies patients' ability to perform various tasks. The scale ranges from 0 (unable to perform any tasks) to 58.20 (able to perform all tasks). Higher scores reflect improved activity or improved heart failure symptoms. Lower scores reflect worsened ability or worsened heart failure symptoms.

Other

MeasureTime frame
Interval Change From Baseline in Biomarkers (High-sensitivity C-reactive Protein, Whole Blood Assay, Brain Natriuretic Peptide)14 days
Correlation Between Interval Changes in Biomarkers, Peak VO2, and VE/VCO214 days

Countries

United States

Participant flow

Recruitment details

11 patients had elevated hsCRP (\>2 mg/L) and were enrolled in the study.

Pre-assignment details

2 patients withdrew consent prior to beginning the study. 1 patient underwent a change in heart failure medication prior to beginning the study and was therefore withdrawn from the study. The 8 remaining patients began the study interventions.

Participants by arm

ArmCount
Anakinra8
Total8

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyAdverse Event1

Baseline characteristics

CharacteristicAnakinra
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
1 Participants
Age, Categorical
Between 18 and 65 years
7 Participants
Age, Continuous55 years
STANDARD_DEVIATION 11
Region of Enrollment
United States
8 participants
Sex: Female, Male
Female
4 Participants
Sex: Female, Male
Male
4 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 8
other
Total, other adverse events
1 / 8
serious
Total, serious adverse events
0 / 8

Outcome results

Primary

Median Interval Change From Baseline in Peak VO2

Peak VO2 is a measurement of oxygen consumption rate during exercise (milliliters of oxygen per minute). It is calculated by continuous measurement of oxygen consumed during exercise while patients breath through a mask/tube. To account for variability in patient size, the oxygen consumption is divided by patient body weight. The outcome measure time frame was 14 days. This means that change in peak VO2 was calculated as the difference between peak VO2 at baseline and 14 days. To calculate this change, we used the mathematical process of subtraction (change in peak VO2 = Peak VO2 \[day 14\] - Peak VO2 \[baseline\])

Time frame: 14 days

ArmMeasureValue (MEDIAN)
AnakinraMedian Interval Change From Baseline in Peak VO23.90 mL/kg/min
Primary

Median Interval Change From Baseline in the Minute Ventilation and Carbon Dioxide Production (VE/VCO2 Slope)

The VE/VCO2 slope is calculated as the ratio of minute ventilation (VE) and carbon dioxide production (VCO2). Because these measurements share the same units, the resultant ratio is unitless. Change in VE/VCO2 slope was calculated as the change in VE/VCO2 slope between baseline and 14 days. We therefore calculated the difference between VE/VCO2 slope measurements that occurred at baseline and at 14 days (change in VE/VCO2 slope = VE/VCO2 slope \[day 14\] - VE/VCO2 slope \[baseline\])

Time frame: 14 days

ArmMeasureValue (MEDIAN)
AnakinraMedian Interval Change From Baseline in the Minute Ventilation and Carbon Dioxide Production (VE/VCO2 Slope)-2.10 (unitless)
Secondary

Interval Change From Baseline in Heart Failure Symptoms as Measured by Duke Activity Status Index (DASI)

The Duke Activity Status Index (DASI) is a scale that quantifies patients' ability to perform various tasks. The scale ranges from 0 (unable to perform any tasks) to 58.20 (able to perform all tasks). Higher scores reflect improved activity or improved heart failure symptoms. Lower scores reflect worsened ability or worsened heart failure symptoms.

Time frame: 14 days

ArmMeasureValue (MEDIAN)
AnakinraInterval Change From Baseline in Heart Failure Symptoms as Measured by Duke Activity Status Index (DASI)6 units on a scale
Other Pre-specified

Correlation Between Interval Changes in Biomarkers, Peak VO2, and VE/VCO2

Time frame: 14 days

Other Pre-specified

Interval Change From Baseline in Biomarkers (High-sensitivity C-reactive Protein, Whole Blood Assay, Brain Natriuretic Peptide)

Time frame: 14 days

Source: ClinicalTrials.gov · Data processed: Mar 26, 2026