Bronchoscopy and Electric Impedance Tomography (EIT) Pilot Study

Bronchoscopy and Electric Impedance Tomography to Investigate the Influence of Bronchoscopy on Pulmonary Regional Ventilation Measurements by Electric Impedance Tomography (EIT)

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01294813
Acronym
Broncho-EIT
Enrollment
20
Registered
2011-02-14
Start date
2011-01-31
Completion date
2011-04-30
Last updated
2011-02-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bronchoscopy, Change in Lung Impedance Due to Ventilation, Electric Impedance Tomography, Improvement the Treatment of the Patient, Recruitment

Keywords

Electric Impedance Tomography (EIT), Ventilation, Bronchoscopy, Lung Impedance, Recruitment

Brief summary

Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Impedance changes in lung ventilation are investigated in mechanically ventilated patients who routinely undergo bronchoscopy in intensive care medicine. Bronchoscopy is performed to suction secretions as well as to analyze the secretions to recognize inflammations and diseases. It is an essential intervention which causes changes in ventilation which remain for 1-2 hours. It is not completely investigated why these changes in ventilation remain for so long time and how they are distributed regionally. Therefore the purpose of this study is to investigate the change in pulmonary regional ventilation in patients who routinely undergo bronchoscopy to possibly generate ideas how to optimize the ventilation after bronchoscopy to optimize the patient´s treatment.

Detailed description

In 20 mechanically ventilated patients who routinely undergo bronchoscopy Electrical Impedance Tomography (EIT) measurements whereby, evaluable data of 10 patients are needed, of about 1-2 minutes are performed directly before, directly after and 10, 30, and 60 minutes after bronchoscopy parallel to the following routine measurements: tidal volume, resistance, compliance, heart rate, blood pressure, SpO2 and blood gas values. Prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax connected with an EIT- device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. The EIT provides a mapping of the distribution of the lung´s electrical impedance and exhibits a far temporal resolution of up to 40 tomograms per second. Because of electrical impedance of the pulmonal tissue is dependant to the air content, the air distribution within the lung over a certain period can be monitored. Analyzing the EIT- data it might be possible to explain the distribution in regional ventilation and how the ventilation could be optimized right after the bronchoscopy to optimize the patient´s treatment.

Interventions

DEVICEElectrical Impedance Tomography (EIT)

EIT measurements of 1-2 minutes are performed in patients who routinely undergo bronchoscopy (during 1.5 hours) before, directly after and 10, 30, 60 minutes after bronchoscopy. Therefore the rubber belt including 16 integrated electrographic electrodes is placed around the patient´s chest and connected with an EIT device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. Pseudonomyzed EIT data are evaluated descriptively.

Sponsors

RWTH Aachen University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Female and male patients \> 18 years old * Mechanically ventilated patients who routinely undergo bronchoscopy

Exclusion criteria

* Pregnancy and Breastfeeding * Active implants, heart pace makers and implanted converter defibrillator * Foreign metallic objects in the thorax * Cardiac valves

Design outcomes

Primary

MeasureTime frameDescription
Comparison of the change in lung impedance due to ventilation before and after bronchoscopy by EIT measurementsSingle Measurement of 1.5 hoursIt will be investigated if there are changes in lung impedance due to changes in ventilation before, directly after and 10, 30, 60 minutes after bronchoscopy in order to investigate their regional distribution and to generate ideas how the ventilation could be optimized to improve recruitment of the patient´s treatment

Countries

Germany

Contacts

Primary ContactStefan Krueger, MD
stkrueger@ukaachen.de0049 241 8080202
Backup ContactSigrid Gloeggler, M.Sc.
sgloeggler@ukaachen.de0049 241 8035226

Outcome results