Novel Non-Invasive Monitoring Parameter in Healthy Volunteers

Novel Cardio-Respiratory Parameter in Healthy Volunteers

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01294514
Enrollment
27
Registered
2011-02-11
Start date
2011-02-28
Completion date
2012-03-31
Last updated
2014-08-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Focus is Respiratory Rate, No Conditions

Keywords

Respiratory Rate

Brief summary

The purpose of this study is to study Non-Invasive Performance evaluation of monitoring algorithm.

Detailed description

Assess equivalency, performance, and accuracy of a new monitoring algorithm in Healthy Volunteers.

Interventions

None listed

Sponsors

Medtronic - MITG
Lead SponsorINDUSTRY

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Subject is 18 or older * Subject is willing and able to provide written consent

Exclusion criteria

* Severe contact allergies to standard adhesive materials * Subjects with abnormalities that may prevent proper application of the device * Women who are pregnant or lactating * Subjects with significant Arrhythmias

Design outcomes

Primary

MeasureTime frameDescription
The Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.Participants were monitorerd on average of 30 minute periodMean and standard deviations of respiration rates collected from healthy volunteers were compared between Covidien Respiration Rate Software, Transthoracic Impedance and Overscored End-Tidal Carbon Dioxide Waveforms. Each volunteer served as its own control.

Secondary

MeasureTime frameDescription
The Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.Participants were monitored on average of 30 minute periodsThe data used for analysis consisted of multiple simultaneous measures of RR\_TTI, RR\_V1.0 and RR\_EtCO2 for each subject. Given N sets of simultaneous RR values for each of P patients, the simultaneous RR values were used to calculate a pair of RMSD values for each subject. The two RMSD values, RMSDRR\_V1.0\_vs\_EtCO2, and RMSDTTI\_vs\_EtCO2, quantify the mean absolute difference in simultaneous estimates of respiratory rate between RR\_V1.0 compared with RR\_EtCO2 and RR\_TTI compared with RR\_EtCO2, respectively for the subjects with 95% confidence of mean ± 3.38 BrPM. The Measure type is Number and represents the RMSD of Covidien Nellcor Respiration Rate Software

Countries

United States

Participant flow

Participants by arm

ArmCount
Healthy Volunteers
Healthy volunteers were studied
27
Total27

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyExcluded due to Arrhythmia1

Baseline characteristics

CharacteristicHealthy Volunteers
Age, Categorical
<=18 years
0 Participants
Age, Categorical
>=65 years
0 Participants
Age, Categorical
Between 18 and 65 years
27 Participants
Age, Continuous35 years
STANDARD_DEVIATION 10
Region of Enrollment
United States
27 participants
Sex: Female, Male
Female
15 Participants
Sex: Female, Male
Male
12 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
0 / 27
serious
Total, serious adverse events
0 / 27

Outcome results

Primary

The Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.

Mean and standard deviations of respiration rates collected from healthy volunteers were compared between Covidien Respiration Rate Software, Transthoracic Impedance and Overscored End-Tidal Carbon Dioxide Waveforms. Each volunteer served as its own control.

Time frame: Participants were monitorerd on average of 30 minute period

Population: One participant was excluded from the analysis based on cardiac arrhythmia

ArmMeasureValue (MEAN)Dispersion
Respiration Rate From Covidien Respiration Rate SoftwareThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.13.2 Breaths Per Minute (BrPM)Standard Deviation 3
Respiration Rate From Endtidal Carbon DioxideThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.13.8 Breaths Per Minute (BrPM)Standard Deviation 3.2
Respiration Rate From Transthoracic ImpedanceThe Covidien Nellcor Respiration Rate Software Shall Determine Respiration Rate Measured as Mean and Standard Deviation With Accuracy That is Non-inferior to Predicate Device.19.5 Breaths Per Minute (BrPM)Standard Deviation 9.4
Secondary

The Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.

The data used for analysis consisted of multiple simultaneous measures of RR\_TTI, RR\_V1.0 and RR\_EtCO2 for each subject. Given N sets of simultaneous RR values for each of P patients, the simultaneous RR values were used to calculate a pair of RMSD values for each subject. The two RMSD values, RMSDRR\_V1.0\_vs\_EtCO2, and RMSDTTI\_vs\_EtCO2, quantify the mean absolute difference in simultaneous estimates of respiratory rate between RR\_V1.0 compared with RR\_EtCO2 and RR\_TTI compared with RR\_EtCO2, respectively for the subjects with 95% confidence of mean ± 3.38 BrPM. The Measure type is Number and represents the RMSD of Covidien Nellcor Respiration Rate Software

Time frame: Participants were monitored on average of 30 minute periods

Population: One participant was excluded from the data analysis based on cardiac arrhythmia

ArmMeasureValue (NUMBER)
Respiration Rate From Covidien Respiration Rate SoftwareThe Covidien Nellcor Respiration Rate Software Shall Calculate Respiration Rate With a Root Mean Square Difference (RMSD) of < 3 Breaths Per Minute Compared With a End-Tidal Carbon Dioxide Waveforms, With 95% Confidence.0.84 Breaths Per Minute (BrPM)
Post Hoc

Calculate Covidien Respiration Rate Software Accuracy as Mean Error +/- Standard Deviation

The Covidien Nellcor Respiration Rate Software shall calculate respiration rate as mean error of +/- standard deviation.

Time frame: Overall average

Population: One participant was excluded from the data analysis based on cardiac arrhythmia

ArmMeasureValue (MEAN)Dispersion
Respiration Rate From Covidien Respiration Rate SoftwareCalculate Covidien Respiration Rate Software Accuracy as Mean Error +/- Standard Deviation0.37 Breaths Per Minute (BrPM)Standard Deviation 0.78

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026