Skip to content

Study of the Effectiveness of Green Diode Laser Light on Body Shaping

A Double-blind, Placebo-controlled Randomized Evaluation of the Effect of the Erchonia Scanner Device (GLS) Green Diode on Body Contouring of the Waist, Hips and Thighs

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01292538
Enrollment
67
Registered
2011-02-09
Start date
2011-02-28
Completion date
2012-06-30
Last updated
2020-02-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Body Contouring

Brief summary

The purpose of this study is to determine if 532nm green diode laser light is effective in body contouring of the waist, hips and thighs.

Detailed description

Weight loss and body contouring are large, constantly-growing fields of cosmetic surgery. However, while the demand for body shaping procedures is constantly on the rise, so is the demand for such procedures to be performed more quickly, simply and most importantly, less invasively; hence the growing popularity of non- to minimally-invasive cosmetic surgery procedures. In 2005, more than 7.5 million minimally-invasive cosmetic procedures were performed, a 35% increase from 2000. In recent years, Erchonia Corporation, a manufacturer of low level lasers, has developed a dual-diode laser that emits 532 nm and 635nm collimated line-generated beams to emulsify fat. In August, 2010, the Erchonia® ML Scanner (MLS) 635nm was cleared by FDA for use as a non-invasive dermatological aesthetic treatment for the reduction of circumference of hips, waist, and thighs. It was determined that the biochemical effect of the Erchonia® MLS stimulates the mitochondria of the adipocyte cells which in turn increases the production of ATP. The newly synthesized ATP triggers the up-regulation of cyclic adenosine monophosphate (cAMP). cAMP has been shown to stimulate cytoplasmic lipase, triggering the conversion of triglycerides into fatty acids and glycerol that can easily pass through the cell membrane. The transitory pore is evidence that the laser is allowing for the movement of fatty acids, glycerol, and triglycerides to pass across the membrane and into extra-cellular space. Through vasodilation of nearby blood vessels and arteries, oxidization of the triglycerides and fatty acids occurs within the extra-cellular space. This pilot study will apply the Erchonia® MLS employing 532 nm green diodes in lieu of 635 nm red diodes to compare the results to those attained using the 635 nm diodes. The Sponsor believes the use of 532 nm diodes may prove as effective as 635 nm diodes combined with a reduction in total procedure administration time from 40 to 30 minutes. It is the goal of this study to evaluate this hypothesis.

Interventions

DEVICEErchonia GLS

532 nm green diode low level laser light device

DEVICEPlacebo laser

Sham light output with no therapeutic benefit

Sponsors

Erchonia Corporation
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* Body Mass Index (BMI) less than 30 kg/m² * Subject indicated for liposuction or use of liposuction techniques for the removal of localized deposits of adipose tissues that do not respond to diet and exercise; specifically for the indication of body contouring in the areas of the waist, hips and bilateral thighs. (As per the American Academy of Cosmetic Surgery's 2006 Guidelines for Liposuction Surgery). * Subject is willing and able to abstain from partaking in any treatment other than the study procedure to promote body contouring and/or weight loss during study participation. * Subject is willing and able to maintain his or her regular diet and exercise regimen without effecting significant change in either direction during study participation.

Exclusion criteria

* Body Mass Index (BMI) of 30 kg/m² or greater. * Diabetic dependent on insulin or oral hypoglycemic medications. * Known cardiovascular disease. * Prior cardiac surgery. * Prior surgical intervention for body sculpting/weight loss, such as liposuction, abdominoplasty, stomach stapling, lap band surgery. * Medical, physical, or other contraindications for body sculpting/weight loss. * Use of medication(s) known to affect weight levels and/or to cause bloating or swelling and for which abstinence during study participation is not safe or medically prudent. * Any medical condition known to affect weight levels and/or cause bloating or swelling. * Diagnosis of, and/or taking medication for, irritable bowel syndrome. * Active infection, wound or other external trauma to the areas to be treated with the laser. * Photosensitivity disorder. * Current cancer or receiving treatment for cancer. * Pregnant, breast feeding, or planning pregnancy prior to study end. * Serious mental health illness such as dementia or schizophrenia; psychiatric hospitalization in past two years. * Developmental disability or cognitive impairment that would preclude adequate comprehension of the informed consent form and/or ability to record study measurements. * Involvement in litigation and/or a worker's compensation claim and/or receiving disability benefits related to weight-related/body shape issues. * Participation in research in the past 30 days.

Design outcomes

Primary

MeasureTime frameDescription
Combined Circumference in Inches of the Waist, Hips and Bilateral Thighs2 weeksMean change in total combined circumference inches of the waist, hips and bilateral thighs from baseline to endpoint evaluation.

Countries

United States

Participant flow

Participants by arm

ArmCount
Erchonia GLS 532nm
532nm green laser light therapy. Erchonia GLS: 532 nm green diode low level laser light device
35
Placebo Laser
Sham light output with no therapeutic benefit Placebo laser: Sham light output with no therapeutic benefit
32
Total67

Baseline characteristics

CharacteristicErchonia GLS 532nmPlacebo LaserTotal
Age, Continuous36.60 years
STANDARD_DEVIATION 10.05
39.03 years
STANDARD_DEVIATION 10.16
38.04 years
STANDARD_DEVIATION 10.08
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants0 Participants0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
29 Participants32 Participants61 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
6 Participants0 Participants6 Participants
Sex: Female, Male
Female
28 Participants25 Participants53 Participants
Sex: Female, Male
Male
7 Participants7 Participants14 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
0 / 350 / 32
serious
Total, serious adverse events
0 / 350 / 32

Outcome results

Primary

Combined Circumference in Inches of the Waist, Hips and Bilateral Thighs

Mean change in total combined circumference inches of the waist, hips and bilateral thighs from baseline to endpoint evaluation.

Time frame: 2 weeks

ArmMeasureValue (MEAN)Dispersion
Erchonia GLS 532nmCombined Circumference in Inches of the Waist, Hips and Bilateral Thighs-3.895 inchesStandard Deviation 3.03
Placebo LaserCombined Circumference in Inches of the Waist, Hips and Bilateral Thighs-1.136 inchesStandard Deviation 2.27

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026