Skip to content

Determining the Safe Dosage of Ascorbic Acid Used in the Treatment of Occluded Totally Implanted Central Venous Catheter

Determining the Safe Dosage of Ascorbic Acid Used in the Treatment of Occluded Totally Implanted Central Venous Catheter.

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01270152
Enrollment
21
Registered
2011-01-05
Start date
2008-10-31
Completion date
2010-07-31
Last updated
2011-01-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Occluded Totally Implanted Central Venous Catheter

Keywords

ascorbic acid, catheterization central venous, nursing care

Brief summary

The hypothesis of the study is to evaluate whether ascorbic acid is able to clear totally implanted central venous catheter

Detailed description

Totally implanted catheter is often occluded and thrombolytic drugs are usually used to restore permeability. In Brazil, the ascorbic acid has been used successfully by a service specialist in cancer treatment. However, no literature on international research that evaluates the efficacy and safety of this procedure. That was why it was decided to develop this research.

Interventions

DRUGAscorbic Acid

comparing three different doses of ascorbic acid: 50 mg, 100 mg and 200 mg administered inside the catheter and maintained for up to 60 minutes

Sponsors

University of Sao Paulo
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosis of partial or complete obstruction of the totally implanted central venous catheter; * No signs of inflammation in the area of the port.

Exclusion criteria

* Use of oral anticoagulants or intravenous administration in the last seven days; * Diagnostic and / or suspected infection in the totally implanted central venous catheter; * Rupture, displacement or fissure of the totally implanted central venous catheter; * Presence of thrombosis in the vein where the catheter is inserted.

Design outcomes

Primary

MeasureTime frameDescription
Restore patency60 minutes after administration of ascorbic acidthe ascorbic acid is administered and remains inside the catheter within 60 minutes. The recovery of permeability is checked every 15 minutes until the maximum of 60 minutes

Secondary

MeasureTime frameDescription
Eosinophil countwithin 24 hoursthe count of eosinophils was determined by collecting blood sample immediately prior to administration of ascorbic acid and 24 hours after

Countries

Brazil

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026