Skip to content

Effect of Socket Preservation Procedure on Dimensional Changes of the Ridge, and Its Efficacy.

Dimensional Changes of the Alveolar Ridge Contour After Socket Preservation, Stability of Implants Placed, and Histological Evaluation of Newly Formed Bone at These Sites.

Status
Completed
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01268982
Enrollment
32
Registered
2011-01-04
Start date
2010-01-31
Completion date
2010-12-31
Last updated
2011-01-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Alveolar Bone Atrophy

Keywords

socket preservation, alveolar ridge augmentation

Brief summary

In this study, the investigators will evaluate the dimensional changes of alveolar bone in the preserved sites in comparison with extraction only conventional healed sockets, as well. 1. Dimensional changes of the alveolar ridge contour after socket preservation in comparison to conventional tooth extraction. 2. Evaluation the stability of implants placed at the preserved sockets. 3. Histological evaluation of newly formed bone at the socket preserved sites in comparison with extracted only healed sites.

Detailed description

Nineteen systematically healthy patients (10 female and 9 male; mean age 38 years old; range 19-57) providing 32 hopeless non-molar teeth were selected and divided into 2 treatment groups: In the test group, following tooth extraction, for 16 sockets (9sockets from 5 female and 7 sockets from 5 male patients) soft and hard tissue measurements include horizontal (Bucco-Lingual dimensions at 1mm,3mm and 7mm at the mid portion from the line connecting two adjacent CEJs) and vertical ridge dimensions (vertical distance from the line connecting two adjacent CEJs at 8 points: Mid-Buccal, Mid-Lingual, Mesial, Distal, Disto-Buccal, Disto-Lingual, Mesio-Buccal, Mesio-Lingual around the socket) will be determined using a caliper and a template. All sockets will be filled with DFDBA and covered with absorbable membrane. Primary coverage will be achieved by full thickness mucosal flap advancement over each socket. Then an acid-etch bridge will be applied for the sites, both to avoid the movement of adjacent teeth to the empty space & also for patients esthetics. 6 months following the procedure, the soft and hard tissue in all the sites will be measured again as it was mentioned previously, plus the measurements gained from CBCT radiographs. Besides, biopsy will be harvested from some of the preserved sites that has enough width with the use of trephine bur no.3 and it was sent for histological evaluation. Subsequently, Implants will be installed in the preserved sites and the implant stability will be measured with the help of Ostell device. The stability will be measured after 4 month following implant insertion with the same device while the implant undergoes the implant exposure procedure. In control group, 16 sockets (9 sockets from 5 female, and 7 sockets from 4 male patients) served as unfilled extraction only group. Following extraction, soft and hard tissue measurements (horizontal and vertical ridge dimensions) will be determined with the use of caliper and template. 6month after extraction, CBCT will be taken from the site and at the time of implant installation, the soft and hard tissue in all sites will be measured in vertical and horizontal dimensions. Furthermore, biopsy from some of the healed sockets with enough width will be taken with the use of trephine bur no.3 and it will be sent for histological examination.

Interventions

PROCEDUREsocket preservation

sockets will be filled with DFDBA and covered with absorbable membrane. Primary coverage will be achieved by full thickness mucosal flap advancement over each socket

Sponsors

Mashhad University of Medical Sciences
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
19 Years to 57 Years
Healthy volunteers
Yes

Inclusion criteria

* Non-molar hopeless teeth * lack of bone volume for ideal implant placement

Exclusion criteria

* Patient's un-wiliness for involvement in the project * contraindication of surgery due to medically-related problems

Design outcomes

Primary

MeasureTime frameDescription
soft and hard tissue vertical and horizontal changes6 monthssoft and hard tissue measurements include horizontal (Bucco-Lingual dimensions at 1mm,3mm and 7mm at the mid portion from the line connecting two adjacent CEJs) and vertical ridge dimensions (vertical distance from the line connecting two adjacent CEJs at 8 points: Mid-Buccal, Mid-Lingual, Mesial, Distal, Disto-Buccal, Disto-Lingual, Mesio-Buccal, Mesio-Lingual around the socket)

Secondary

MeasureTime frame
histologic evaluation and implant stability measurement10 months

Countries

Iran

Outcome results