Skip to content

MIHS Emergency Department CPR Quality Improvement Project

MIHS Emergency Department CPR Quality Improvement Project

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01245699
Enrollment
115
Registered
2010-11-22
Start date
2010-06-09
Completion date
2016-03-09
Last updated
2019-04-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Arrest

Keywords

Cardiac arrest, CPR, quality improvement

Brief summary

The investigators will quantify the quality of chest compressions provided in the Emergency Department and determine whether the quality of chest compressions is related to patient outcome. The quality of chest compressions and patient outcomes will be assessed both before and after the introduction of audiovisual feedback in real time.

Detailed description

The Emergency Department will be using E-series unit manufactured by ZOLL Medical Group (Chelmsford, MA). These units are equipped with an accelerometer-based system that allows for measurement of chest compression depth and rate. These units are also equipped with RealCPRHelp, and FDA-approved technology that provides real-time audiovisual feedback to providers on the quality of chest compressions. In the first phase of the project, the ED providers will utilize the E-series units to treat all patients requiring chest compressions.

Interventions

BEHAVIORALscenario-based training, real-time audiovisual CPR feedback, and post-event debriefing

scenario-based training for CPR, real-time audiovisual CPR feedback using R Series monitor-defibrillator during treatment, and post-event debriefing

Sponsors

Valleywise Health
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Chest Compression before and after RealCPRHelp

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years old or older

Exclusion criteria

* less than 18 years old

Design outcomes

Primary

MeasureTime frameDescription
CPR Qualityduring CPRChest Compression Release Velocity
CPR Quality-compression FractionDuring CPRChest Compression Fraction indicating the percentage of time in which chest compressions are done by rescuers during a cardiac arrest
CPR Quality-Chest Compression RateDuring CPRMean Chest Compression Rate
CPR Quality-compression Depthduring CPRMeasurement of chest compression depth
CPR Quality-percent of >51mm Compressionsduring CPRPercent of Chest Compressions greater than 51mm
CPR Quality- Pre-shock PauseDuring CPRPre-shock pause: time from cessation of CPR to shock delivery

Countries

United States

Participant flow

Participants by arm

ArmCount
Phase I
Before training
52
Phase 2
After training.
49
Total101

Baseline characteristics

CharacteristicPhase IPhase 2Total
Age, Customized
Mean Age of participants
56 years60 years58 years
Sex: Female, Male
Female
19 Participants8 Participants27 Participants
Sex: Female, Male
Male
33 Participants41 Participants74 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 520 / 49
other
Total, other adverse events
0 / 520 / 49
serious
Total, serious adverse events
0 / 520 / 49

Outcome results

Primary

CPR Quality

Chest Compression Release Velocity

Time frame: during CPR

ArmMeasureValue (MEAN)
Before TrainingCPR Quality314 mm/s
After Training.CPR Quality442 mm/s
p-value: <0.001Kruskal-Wallis
Primary

CPR Quality-Chest Compression Rate

Mean Chest Compression Rate

Time frame: During CPR

ArmMeasureValue (MEAN)
Before TrainingCPR Quality-Chest Compression Rate125 CCs/min
After Training.CPR Quality-Chest Compression Rate125 CCs/min
p-value: 0.65Kruskal-Wallis
Primary

CPR Quality-compression Depth

Measurement of chest compression depth

Time frame: during CPR

ArmMeasureValue (MEAN)
Before TrainingCPR Quality-compression Depth46.7 mm
After Training.CPR Quality-compression Depth61.6 mm
Primary

CPR Quality-compression Fraction

Chest Compression Fraction indicating the percentage of time in which chest compressions are done by rescuers during a cardiac arrest

Time frame: During CPR

ArmMeasureValue (MEDIAN)
Before TrainingCPR Quality-compression Fraction84.3 % of time chest compressions are done
After Training.CPR Quality-compression Fraction88.4 % of time chest compressions are done
p-value: 0.1Kruskal-Wallis
Primary

CPR Quality-percent of >51mm Compressions

Percent of Chest Compressions greater than 51mm

Time frame: during CPR

ArmMeasureValue (MEDIAN)
Before TrainingCPR Quality-percent of >51mm Compressions30.6 percentage of chest compressions >51mm
After Training.CPR Quality-percent of >51mm Compressions87.4 percentage of chest compressions >51mm
p-value: <0.001Kruskal-Wallis
Primary

CPR Quality- Pre-shock Pause

Pre-shock pause: time from cessation of CPR to shock delivery

Time frame: During CPR

ArmMeasureValue (MEDIAN)
Before TrainingCPR Quality- Pre-shock Pause9.7 sec
After Training.CPR Quality- Pre-shock Pause5.9 sec

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026