Skip to content

Optical Coherence Tomography Guided Transepithelial Phototherapeutic Keratectomy

Optical Coherence Tomography Guided Transepithelial Phototherapeutic Keratectomy

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01243931
Enrollment
80
Registered
2010-11-19
Start date
2011-06-30
Completion date
2026-12-31
Last updated
2024-02-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Corneal Opacity

Keywords

Phototherapeutic keratectomy, Optical coherence tomography, Corneal opacity, Corneal dystrophy

Brief summary

Optical Coherence Tomography (OCT) machines are non-contact instruments that can measure the depth of scars and other causes of cloudiness in the front of the cornea. The purpose of this study is to determine whether OCT-guided settings for the lasers used for removal of corneal scars and other partial-thickness corneal defects result in improved vision in patients receiving these procedures.

Detailed description

The long-term goal of this project is to utilize newly available very high-speed OCT technology to guide surgical treatments of corneas with superficial opacities and irregularities. OCT is well known for its exquisite resolution, but until recently it has not had sufficient speed to capture the shape of the cornea because of eye motion during OCT scanning. The development of Fourier-domain OCT (FD-OCT) technology has made the requisite speed possible. Eyes with superficial opacities (corneal scars and stromal dystrophies) can be treated by phototherapeutic keratectomy (PTK). Currently, many surgeons rely on subjective slit-lamp impression of opacity depth to guide PTK and repeat slit-lamp examinations during surgery to determine if the opacity has been sufficiently reduced. Unpredictable hyperopic shifts can occur after PTK. The aim of this project is to develop methods for imaging the cornea with an FD-OCT system that will precisely measure corneal shape and use this information to guide surgery. Patients with irregularly shaped corneas could have their vision restored by reshaping the corneas with a procedure that combines the precision of OCT and lasers.

Interventions

DRUGOCT-guided laser phototherapeutic keratectomy

Preoperative measurements from the OCT are used to assist the calculation in deciding the laser depth settings for removal of anterior corneal opacities and defects in the phototherapeutic PTK procedure. The surgeon uses the OCT data to plan a range of treatment parameters to remove most of the opacity while preserving at least 250 microns of residual corneal stroma.

Sponsors

National Eye Institute (NEI)
CollaboratorNIH
Oregon Health and Science University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients with vision primarily limited by superficial opacities and irregularities that could be removed by PTK while leaving at least 250 µm.

Exclusion criteria

* Inability to give informed consent * Inability to maintain stable fixation for OCT imaging * Inability to commit to required visits to complete the study * Deep corneal opacities and irregularities * Cataracts, retinal disease, glaucoma, or other eye conditions that may limit the visual outcome after surgery

Design outcomes

Primary

MeasureTime frameDescription
Improvement in best spectacle-corrected visual acuity (BSCVA) after PTK12 months post-procedureThe primary goal of the trial is to determine the efficacy of the OCT-guided PTK treatment of corneal opacities. During the course of the trial, we will compare the predictive accuracy of the original OCT-guided PTK planning system to the OCT topography-guided system. BSCVA will be measured in typical Snellen acuity notation as 20/xx (feet)

Secondary

MeasureTime frameDescription
Improvement in uncorrected visual acuity (UCVA), refractive error, and higher order aberrations12 months post-procedureA second goal is to develop a more sophisticated OCT guidance system incorporating OCT topography of anterior and posterior corneal surfaces and to develop a mathematical model that relates epithelial thickness variation to corneal mean curvature. During the course of the trial, we will compare the predictive accuracy of the original OCT-guided PTK planning system to the OCT topography-guided system. UCVA will be measured in typical Snellen acuity notation as 20/xx (feet)

Countries

United States

Contacts

Primary ContactHumberto Martinez, COT
martinhu@ohsu.edu503-494-7712
Backup ContactDenny Romfh, OD
romfhd@ohsu.edu503-494-4351

Outcome results

None listed