Lung Cancer
Conditions
Keywords
CT, lung nodule biopsy, Respiration Gated, Lung Cancer
Brief summary
The primary outcome of this study is to investigate the accuracy of respiration gated laser guided CT lung nodule biopsy through a prospective randomized trial using a bellows-based breath hold monitoring system. Secondary outcome is the rate of complications using laser guided CT biopsy in general and with bellows-based breath hold monitoring system. The study has approval from the The Danish National Committee on Biomedical Research Ethics (ref no: H-4-2010-fsp 1).
Interventions
Bellows-Based breath hold monitoring system: The bellows-based breath hold system (IBC, Mayo Clinic Medical Devices, USA) contains of 2 elements; one belt which is strapped around the thorax of the patient and a voltage controlled light unit with 8 lights. Belt stretch from respiratory motion is converted into voltage readings and displayed on the light unit giving biofeedback as different lights are activated depending on the dept of the respiration. Patients are instructed to keep respiration constant at a certain dept during the second the guide needle is inserted by controlling their breath with the help of the light unit. The patient is given a brief introduction to the system as to how the lights get turned on and off due to respiration motion before the biopsy is preformed.
Sponsors
Study design
Eligibility
Inclusion criteria
Patients with indeterminate lung nodules referred from the department of pulmonary medicine at Gentofte Hospital, Denmark for a CT guided biopsy are considered for inclusion in this study. The biopsy was preformed as part of regular clinical work up of the patient at the department of Radiology Gentofte Hospital, Denmark. Both men and women were included and no age restrictions were applied.
Exclusion criteria
Excluded from biopsy were those with poor pulmonary function test with a forced expired volume in the first second (FEV1) \< 0.5 L, INR\>1.2, blood cloth level under 200\* and ECG with sign of ischemic heart disease. The trial is planned to begin 1.March 2010 and run for 2 years ending at 29 February 2012. During this time approx. 400 participants planned for biopsy are accepted to be included in the trial.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Accuracy of respiration gated laser guided CT lung nodule biopsy | After 2 years | The primary outcome of this study is to investigate the accuracy of respiration gated laser guided CT lung nodule biopsy through a prospective randomized trial using a bellows-based breath hold monitoring system. |
Countries
Denmark