Comprehensive Evaluation of Ischemic Heart Disease Using MRI

Comprehensive Evaluation of Ischemic Heart Disease Using MRI

Status
Completed
Phases
Phase 2Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01234870
Enrollment
40
Registered
2010-11-04
Start date
2010-06-30
Completion date
2012-01-31
Last updated
2014-09-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atherosclerosis, Coronary, Heart Disease, Ischemic

Keywords

Myocardial Perfusion Imaging, Magnetic Resonance Imaging

Brief summary

The purpose of the study is to assess the diagnostic performance of fully automated motion corrected (MC) first pass myocardial perfusion MRI, compared to the original non-corrected first pass myocardial perfusion images in a cohort of patients with suspected ischemic heart disease, using coronary angiography as the reference standard. It is expected that this improved comprehensive protocol for cardiac MRI be accurate at detecting significant coronary artery disease and may obviate the need for other more expensive and invasive diagnostic tests currently used.

Detailed description

Coronary heart disease is the leading cause of death and disability in the US, accounting for about one-third of all deaths in subjects over age 35. With the development of newer Magnetic Resonance Imaging (MRI) techniques, such as faster pulse sequences and parallel imaging, cardiac MRI has become a routine tool for the evaluation and detection of myocardial ischemic disease. First pass myocardial perfusion (FPMP) using MRI is increasingly being used to assess ischemic heart disease. MRI offers the advantages of spatial resolution sufficient to differentiate between subendocardial and subepicardial perfusion; shorter examination time and also lack of ionizing radiation. Left ventricle cine gradient echo imaging can be used to assess regional ventricular function. Left ventricular myocardial viability can also be easily assessed at the same time in order to determine the amount of viable left ventricular myocardium and the percentage of irreversibly scarred myocardium by delayed enhanced images. Viability imaging is usually added to the perfusion protocol to increase specificity by allowing detection of fixed perfusion defects, which represent scar. The ultimate cardiac MRI protocol would be to combine both of these imaging strategies with a reliable and accurate coronary Magnetic Resonance Angiography(MRA) technique, such that obstructive coronary artery disease could be evaluated comprehensively at the same time. If all of these techniques can be combined together in a single study, it may be feasible to finally achieve a one stop shop for cardiac Magnetic Resonance Imaging.

Interventions

DRUGGadolinium
DRUGAdenosine

Sponsors

Astellas Pharma US, Inc.
CollaboratorINDUSTRY
Bayer Healthcare Pharmaceuticals, Inc./Bayer Schering Pharma
CollaboratorINDUSTRY
Northwestern University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

Under an Institutional Committee on Human Research board approved protocol 80 patients with a suspected myocardial ischemic disease recruited from the cardiac cath laboratory will be recruited in this prospective study. Volunteers will be recruited for the purpose of protocol development and will not be included in analysis. All subjects will be screened for glomerular filtration rate (GFR) within 24 hours before the exam. All patients must have a GFR \> 30 mL/min/1.73m2 to be part of the study. All subjects will be selected following the Nephrogenic Systemic Fibrosis (NSF) guidelines. All dialysis patients or end-stage renal disease patients with a creatinine clearance of \< 30 mL/min will not be selected for the study to avoid NSF. Patients with GFR \< 60 ml/min but \>30 ml/min will receive a reduced dose of Gadolinium contrast (0.1 ml/kg).

Exclusion criteria

1. Age \<18 years; 2. Known contraindication to MR imaging (such as pacemaker placement, magnetic implants, etc); 3. Claustrophobia; 4. Inability to perform an adequate breath-hold for imaging, 5. Inability to provide informed consent; 6. all subjects will be will be screened for GFR within 24 hours before the exam and subjects presenting with GFR \< 30 ml/min will be excluded; 7. Pregnant and lactating women; 8. Patients with hypersensitivity to gadolinium contrast agents, metoprolol, adenosine, or nitroglycerin; 9. Contra indication for Adenosine 1. 2nd- or 3rd-degree atrioventricular block (except in patients with a functioning artificial pacemaker) 2. Sinus node disease (except in patients with a functioning artificial pacemaker) 3. Unstable angina 4. Acute myocardial infarction 5. Known or suspected bronchoconstrictive or bronchospastic lung disease (e.g., asthma) 6. Hypersensitivity to adenosine 7. Caffeine within 12-24 hours 8. Theophylline and Dipyridamole products within 24 hours. 10. Contra indication for Metoprolol 1. sinus bradycardia 2. heart block greater than first degree 3. Cardiac Failure 4. Bronchospastic Disease 11. Contra indication for Nitroglycerin 1. Early myocardial infarction, severe anemia, increased intracranial pressure, and those with a known hypersensitivity to nitroglycerin. b .Administration of Nitrostat (nitroglycerin tablets, USP) is contraindicated in patients who are using Viagra® since Viagra has been shown to potentiate the hypotensive effects of organic nitrates.

Design outcomes

Primary

MeasureTime frameDescription
Magnetic Resonance Image Quality RatingCross sectional study; magnetic resonance images were obtained on all patients using two different acquisition methods.The purpose of the study is to assess the incremental value of diagnostic performance using a fully-automated, motion-corrected (MC) first pass myocardial perfusion image acquisition protocol compared to images obtained under a non-corrected, breath-hold, shallow-breathing first pass myocardial perfusion image acquisition protocol in patients with suspected ischemic heart disease. The MR images resulting from two different image acquisition techniques, including Non-Corrected Breath-Hold Shallow-Breathing and Motion-Corrected, were assessed independently by two radiologists (average of 7 years of experience in reading cardiac MRI) using the American Heart Association modified 16 segment model and were evaluated using a four point Likert scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent) for image quality

Secondary

MeasureTime frameDescription
Number of Participants With Adverse Events to Demonstrate Feasibility of a Comprehensive Cardiac Magnetic Resonance Imaging Protocol14 daysAdverse events relating to administration of adenosine during a coronary heart disease comprehensive cardiac MRI study.

Countries

United States

Participant flow

Participants by arm

ArmCount
Adenosine
Adenosine (Adenoscan) will be infused intravenously at a dose of 0.14mg/kg/min for a total of 4 mins. adenosine: Adenosine will be infused intravenously at a dose of 0.14mg/kg/min for a total of 4 mins
40
Total40

Baseline characteristics

CharacteristicAdenosine
Age, Continuous60.9 years
STANDARD_DEVIATION 8.21
Body Mass Index (BMI)29.57 kg/m^2
STANDARD_DEVIATION 5.83
Ethnicity (NIH/OMB)
Hispanic or Latino
2 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
32 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
6 Participants
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants
Race (NIH/OMB)
Asian
0 Participants
Race (NIH/OMB)
Black or African American
6 Participants
Race (NIH/OMB)
More than one race
0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants
Race (NIH/OMB)
Unknown or Not Reported
4 Participants
Race (NIH/OMB)
White
30 Participants
Region of Enrollment
United States
40 participants
Sex: Female, Male
Female
13 Participants
Sex: Female, Male
Male
27 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
— / —
other
Total, other adverse events
0 / 40
serious
Total, serious adverse events
0 / 40

Outcome results

Primary

Magnetic Resonance Image Quality Rating

The purpose of the study is to assess the incremental value of diagnostic performance using a fully-automated, motion-corrected (MC) first pass myocardial perfusion image acquisition protocol compared to images obtained under a non-corrected, breath-hold, shallow-breathing first pass myocardial perfusion image acquisition protocol in patients with suspected ischemic heart disease. The MR images resulting from two different image acquisition techniques, including Non-Corrected Breath-Hold Shallow-Breathing and Motion-Corrected, were assessed independently by two radiologists (average of 7 years of experience in reading cardiac MRI) using the American Heart Association modified 16 segment model and were evaluated using a four point Likert scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent) for image quality

Time frame: Cross sectional study; magnetic resonance images were obtained on all patients using two different acquisition methods.

ArmMeasureGroupValue (MEAN)Dispersion
Ischemic Heart Disease PatientsMagnetic Resonance Image Quality RatingMotion Corrected Images3.57 units on a likert scaleStandard Deviation 0.66
Ischemic Heart Disease PatientsMagnetic Resonance Image Quality RatingNon-Corrected Breath-Hold, Shallow-Breathing Image2.55 units on a likert scaleStandard Deviation 0.81
Comparison: The MR images resulting from two different image acquisition techniques, including Non-Corrected Breath-Hold Shallow-Breathing and Motion-Corrected, were assessed independently by two radiologists (average of 7 years of experience in reading cardiac MRI) using the American Heart Association modified 16 segment model and were evaluated using a four point Likert scale (1 = poor, 2 = fair, 3 = good, and 4 = excellent) for image qualityp-value: <0.001Wilcoxon (Mann-Whitney)
Secondary

Number of Participants With Adverse Events to Demonstrate Feasibility of a Comprehensive Cardiac Magnetic Resonance Imaging Protocol

Adverse events relating to administration of adenosine during a coronary heart disease comprehensive cardiac MRI study.

Time frame: 14 days

ArmMeasureValue (NUMBER)
Ischemic Heart Disease PatientsNumber of Participants With Adverse Events to Demonstrate Feasibility of a Comprehensive Cardiac Magnetic Resonance Imaging Protocol0 occurances of adverse events