New in Vitro Diagnostic Test for Oral Malodour

New in Vitro Diagnostic Test for Oral Malodour: First Prototype Evaluation

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01226251
Acronym
Striptest
Enrollment
150
Registered
2010-10-22
Start date
2011-01-31
Completion date
2013-03-31
Last updated
2012-10-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Halitosis

Keywords

oral malodour, halitosis, Subjects consulting a bad breath clinic

Brief summary

This study will assess the ability of a first prototype (strip) of a new chair side test to detect oral malodour. The strip is based on a new enzymatic reaction able to detect amines in saliva. Previous studies already showed significant correlations between oral malodor and the levels of amines in saliva. The limitation in their use as markers of oral malodour is the fact that the detection is usually carried out by complex techniques (High Performance Liquid Chromatography(HPLC)and Solid-Phase Micro Extraction-Gas Chromatography/Mass Spectrometry (SPME-GC/MS)). The results of the new enzymatic reaction can be evaluated by means of a colorimetric scale without necessity of extra apparatus. The study will be carried out with volunteers recruited at a multidisciplinary consultation for bad breath, organized at the University Hospital Leuven, Belgium. The paper strip will be used before the routine evaluation (organoleptic score (OS), the gold standard method for the diagnosis of halitosis and the level of volatile sulphur compounds (VSC), the most used adjunct tool to diagnose halitosis). The results of the new chair side test (strip) will be correlated with the OS and VSC measurements (OralChroma™, Halimeter®). The sensitivity, specificity and positive and negative predicted values of the new chair side test will be calculated. The cut-off values for a yes/no test will be determined. The meaning of color scores will be analyzed to assign a meaningful outcome to each score with relation to odor intensity.

Interventions

DEVICEIn vitro chair side test

Colour evaluation of a strip

Sponsors

Universitaire Ziekenhuizen KU Leuven
Lead SponsorOTHER
Gaba International AG
CollaboratorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
Yes

Inclusion criteria

* Adults (≥18 years * With no evidence of bad breath or bad breath of intra-oral cause (oral malodour) * Non-smokers or smokers from whom the organoleptic evaluation can be performed (no interference from smoke odour)

Exclusion criteria

* Smokers from whom the organoleptic evaluation can not be performed because of interference from smoke odour * Presence of active caries * Presence of sinusitis or any other Oro-pharyngeal problem * On medications which can cause malodour * Reduced salivary flow due to pathological reasons (e.g. Sjögren syndrome) * Any oral pathophysiological condition or any oral disease (e.g. oral cancer, mucositis) * Pregnancy and nursing * Situation considered not compatible with the study according to the investigator's opinion; the latter includes: persons under homeopathic therapy, patients who used antibiotics during the 2 months before the study, patients frequently using chewing gum, patients under corticosteroids or other serious medications.

Design outcomes

Primary

MeasureTime frameDescription
Colour evaluation of the new chair side testOnce (during the first consult to the clinic)The colour will be assessed before all the other test and after 4 minutes of contact between the strip and the saliva of the volunteer.

Secondary

MeasureTime frameDescription
Organoleptic evaluation (OS)Once (during the first consult to the clinic)The OS will be determined by a trained and calibrated judge as described in the literature. Briefly, patients will be asked to count from one to eleven and the judge rated the exhaled air on a 0 to 5 score ( 0 represents absence of odour, 1 is given for barely noticeable odour, 2 for slight malodor, 3 for moderate malodor, 4 for strong malodor and 5 for severe malodor). The judge will also evaluate nasal breath in order to exclude extra-oral causes of halitosis and the odor of a sample of the tongue coating, if present.
Total VSC readingOnce (during the first consult to the clinic)The global concentration of sulphur containing compounds will be measured using a portable breath analyzer (Halimeter®, Interscan cooperation, Chatsworth, US. The maximum level attained (ppb) is determined by direct readings from the analog scale of the monitor.
Specific VSC readingsOnce (during the first consult to the clinic)Hydrogen sulphide, methyl mercaptan and dimethyl sulphide will be measured using a commercially available system (OralChroma™, Abilit Corporation; Osaka City, Japan). This portable gas chromatograph is equipped with an indium oxide semiconductor gas sensor. The concentration values (ppbv) of the three gases will be recorded.