Heart Failure
Conditions
Keywords
Heart failure
Brief summary
This study aims to investigate the effect of a pacemaker device used in heart failure patients which is called Cardiac Resynchronisation Therapy (CRT). Specifically the investigators aim to investigate if the CRT pacemaker has an effect on breathing stability in these patients and particularly breathing stability at night. Our theory is that the CRT pacemaker may improve the stability of breathing in patients with heart failure.
Detailed description
AIM To investigate the effect of Cardiac Resynchronisation Therapy (CRT) on chemosensitivity in patients with Chronic Heart Failure with and without Sleep Disordered Breathing (SDB). OBJECTIVE To conduct a physiological observational study to measure hypercapnic ventilatory responses in a group of CHF patients before and 3 months after implantation of clinically indicated CRT devices. Additionally to conduct nocturnal polysomnography to establish if any change in chemosensitivity is related to the presence of SDB at baseline and, where present, any change in SDB after implantation. HYPOTHESIS Primary hypothesis: CRT implantation will be associated with a reduction in the hypercapnic ventilatory response from baseline to 3 months post implantation. Additional hypothesis: This reduction in hypercapnic ventilatory response after CRT implantation will be greatest in those CHF patients with SDB at baseline.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
1. Age ≥18 years old 2. Fulfil the current guidance for the implantation of a CRT device; optimal medical treatment for heart failure, broad QRS complex on electrocardiogram with or without evidence of cardiac dyssynchrony as appropriate, LVEF \<35%, functional impairment as defined by an NYHA class of III-IV 3. Clinically stable with no unplanned admission to hospital for preceding 4 weeks 4. No changes in medications for heart failure in preceding 4 weeks 5. Able to read and understand patient information sheet and give informed consent
Exclusion criteria
1. On positive pressure treatment for known sleep disordered breathing at the time of inclusion 2. Other known condition (untreated) likely to significantly disturb sleep eg. Restless legs syndrome, pain from any cause etc. 3. Pregnancy
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Change in chemosensitivity before and after CRT implantation | 3 months | We will look primarily at the effect of CRT implantation on chemosensitity which we will measure using the ventilatory sensitivity to carbon dioxide. |
Countries
United Kingdom