Skip to content

Using HandTutor With Traumatic Hand Injuries: Characterizing the System

Using HandTutor With Traumatic Hand Injuries: Characterizing the System

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01210833
Enrollment
30
Registered
2010-09-29
Start date
2010-10-31
Completion date
2014-12-31
Last updated
2018-04-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hand Injuries

Keywords

Finger Fractures, Tendon Injuries, Soft Tissue Injuries

Brief summary

HandTutor is a computerized system designed to evaluate and rehabilitate hand function. It is composed of a glove with optic sensors detecting the movements of the wrist and the fingers with a biofeedback software designed to evaluate and then to exercise the hand movements through supplying a variety of computer graphic patterns. The HandTutor has been used and tested with a stroke population, and it seems potential to be used with hand injuried population. As a first step, it is important to investigate the characteristics of the system and how it is matching the hand injuried population. The purpose if this study is to characterize the HandTuror system and the focused objectives are: 1. To examine the test-retest reliability of the system when measuring the range of motion (ROM) of the the fingers among healthy people (control group). 2. To examine the correlation between the ROM measured by the HandTutor and the ROM measured by conventional assessment tools (goniometer). 3. To examine the ability of the system to distinguish between healthy people and hand injured people. 4. To examine the correlation between the performance in the HandTutor (in the games part), and the performance in functional activities. 5. To examine the participants feedback for using the HandTutor (degree of enjoyment).

Interventions

DEVICEHandTutor System

Computerized system designed to evaluate and rehabilitate hand function. It is composed of a glove with special sensors detecting the movements of the wrist and the fingers, with a biofeedback software designed to evaluate and then to exercise the hand movements through supplying a variety of computer graphic patterns.

Sponsors

Meir Medical Center
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* Hand Injuries causing a disfunction of one finger or more of the fingers 2nd-5th. * Six weeks at least after the injury/surgery. * Allowed to exercise their fingers with no contraindications according to the orthopedic surgeon instructions. * With no open wounds.

Exclusion criteria

* Peripheral nerves injuries. * Digital nerves injuries. * Sensation problems. * CRPS-complex regional pain syndrome. * Cognitive impairments. * Head trauma.

Design outcomes

Primary

MeasureTime frameDescription
range of movement (ROM)up to 12 months after the injuryPassive and active ROM measured by goniometer, passive and active ROM measured by HandTutor

Secondary

MeasureTime frameDescription
performance in HandTutorup to 12 months after the injuryThe final score the participants get when exercising with the HandTutor.
daily life functioningup to 12 months after the injuryMeasured by DASH-Disability of Arm,Shoulder and Hand Questionnaire, and by Jebsen-Taylor Hand Function Test.
motor performance skillsup to 12 months after the injuryMeasured by Purdue Pegboard Test
enjoymentup to 12 months after the injuryMeasured by SFQ-Specific feedback questionnaire.
painup to 12 months after the injuryMeasured by VAS-Visual analogue scale.

Countries

Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026