Skip to content

A Prospective, Post-marketing Registry on the Use of ChondroMimetic for the Repair of Osteochondral Defects

A Prospective, Open Label, Multi-centre, Post-marketing Registry on the Use of ChondroMimetic for the Repair of Osteochondral Defects

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01209390
Acronym
OMCM
Enrollment
8
Registered
2010-09-27
Start date
2010-09-30
Completion date
2016-04-30
Last updated
2011-09-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Osteochondral Defects

Keywords

osteochondral, regenerative, repair, cartilage lesion

Brief summary

The objective of this post-marketing study is to confirm the clinical efficacy and safety outcome of treatment with ChondroMimetic in a patient population within the proposed indication (osteochondral cartilage defects), over a 36 months post-implantation follow-up period. The primary objective is to collect post-marketing safety data in a real life setting by means of (S)ADR reporting. The secondary objectives are: * Clinical outcome as assessed by patient reported EuroQoL-5D * Structural repair as assessed by MRI * The number of treatment failures and the time to treatment failure * The ease of use of ChondroMimetic as reported by the surgeon

Interventions

The Chondromimetic implant is intended to serve as a scaffold for cellular and tissue ingrowth in osteochrondral defect repair such as bone and/or cartilage. The plug consists of a chondral layer with collagen and GAG and an osseus layer with collagen, GAG, and calcium phosphate.

Sponsors

TiGenix n.v.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

1. Signed patient informed consent 2. Shallow osteochondral defect ≤ 12 mm diameter and ≤ 8 mm depth in weight bearing area 3. Agree to actively participate in a rehabilitation protocol

Exclusion criteria

1. Severe vascular or neurological disease 2. Uncontrolled diabetes 3. Severe degenerative joint disease 4. Pregnancy 5. Presence of infection at the site or in the joint space (e.g. osteomyelitis) 6. Diagnosis rheumatoidism 7. Advanced osteoarthritis as judged by the surgeon 8. Drug and/or alcohol abuse 9. Hypercalcemia 10. Known allergy to any of the components of the device (e.g. bovine collagen) 11. Bleeding disorders of any etiology 12. Steroidal or immunosuppressive maintenance therapy

Design outcomes

Primary

MeasureTime frameDescription
Safety dataon ongoing basis up to 3 yearsSafety data as measured by adverse device reactions

Secondary

MeasureTime frameDescription
EuroQoL-5Dbaseline, 6, 12, 24, 36 monthsThe EQ-5D is a descriptive system of health-related quality of life states consisting of five dimensions (mobility, self-care, usual activities, pain/discomfort, anxiety/depression) each of which can take one of three responses. The responses record three levels of severity (no problems/some or moderate problems/extreme problems) within a particular EQ-5D dimension
MRIbaseline, 12, 24, 36 monthsStructural repair will be assessed by MRI. The available MRIs will be collected and scored by an independent radiologist, using the published MOCART score , and one additional item, level of the subchondral bone plate.
Failure rate3 yearsTreatment failure is defined as a re-intervention on the index lesion, prompted by persistence or recurrence of symptoms related to the index knee. The date of failure is the actual date of re-intervention.

Countries

Belgium, Germany, Hungary, United Kingdom

Outcome results

None listed