Skip to content

Usability of Ringed Polytetrafluoroethylene Graft for Venous Vascular Reconstruction of Living Donor Liver Transplantation

Prospective Study on Usability of Ringed Polytetrafluoroethylene Graft for Venous Vascular Reconstruction of Living Donor Liver Transplantation

Status
UNKNOWN
Phases
Phase 2Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01205802
Acronym
MHVLDLT
Enrollment
200
Registered
2010-09-21
Start date
2010-08-31
Completion date
2012-07-31
Last updated
2010-09-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Patency, Hepatic Venous Congestion

Keywords

patency, hepatic venous congestion, liver transplantation

Brief summary

Middle hepatic vein (MHV) reconstruction with an interposition vessel graft has been settled as a standard procedure for living donor liver transplantation (LDLT) using a right lobe graft. Increasing demand of vessel graft in the situation of limited resources of allograft led the investigators to search for new vessel substitutes. Since the use of thin-walled expanded polytetrafluoroethylene (PTFE) graft showed poor long-term patency, a prospective study is going to be performed to enhance the clinical usability of expanded PTFE graft. A clinical study intends to know how to maintain its luminal flow effectively by using ringed PTFE graft. During 12 months of study period, ringed PTFE graft will be used for reconstruction of MHV reconstruction. The investigators expect that ringed PTFE graft seems to be a more useful alternative than usual PTFE graft when adequate autologous or allogenic vessel graft is not available.

Detailed description

Since late 2009, the relative supply of vessel allograft over the increasing demand on LDLT became seriously shortened in the investigators' institution. Thus the investigators decide to use prosthetic vascular grafts more frequently than before. After a preliminary study from January 2010 to July 2010, a prospective case-controlled study will be performed for 12 months from August 2010 to July 2011. The case number of patients requiring MHV reconstruction is expected as being 200 during the study period. Of them, currently using homologous or autologous vessel grafts will be used for 150. Due to expected shortage of such human vessels, other 50 will undergo MHV reconstruction using ringed PTFE graft in addition to available autologous or homologous vessel segments. According to the implications from precedent animal and preliminary studies, the investigators set up the institutional guidelines for use of prosthetic vascular graft during MHV reconstruction of LDLT as follows: use only ringed PTFE graft; choose graft of a larger-caliber (≥1 cm); apply an intervening patch when making an end-to-side anastomosis for MHV branch of the segment 8 (V8); provide a slight redundancy in length; make the IVC-side orifice much larger than the usual; perform flow surveillance more frequently with dynamic CT scan and Doppler ultrasonography; place a stent as soon as any significant luminal narrowing is detected; and keep hypocoagulable state for at least 2 weeks and anti-platelet therapy for 6 months. Technical knacks for secure suture include minimal removal of the rings attached at the surface of the ringed PTFE, use of PTFE suture material (GORE-TEX SUTURE; GORE-TEX, W.L. Gore & Associated, Inc., USA) - a non-absorbable monofilament made of expanded PTFE enabling 1:1 needle to thread ratio to minimize needle hole bleeding at anastomoses, making a redundant patch plasty for end-to-side branch anastomosis especially for V8, and spray application of fibrin glues for suture-point minute bleedings and for stable fixation of PTFE graft at the liver cut surface. The primary goal for this clinical study is set to keep up the rate of luminal patency as 100% for at least 1 month after MHV reconstruction for LDLT. Any occurrence of flow disturbance at luminal narrowing greater than 50% of the original cross-sectional area at 1 month should make the guidelines revise extensively. This protocol is designed as being a prospective case-controlled study for 1 year. The use of PTFE graft for various hepatobiliary surgical procedures including LDLT has been permissible in the investigators' institution. Only after parenchymal transection of the donor liver, the size and shape of suitable vessel allograft for MHV reconstruction is determined. Thus the use of PTFE graft will be decided at this time after checking the list of all available allograft stored at the institutional tissue bank. The indication of PTFE use will be confined to the occasions that adequate allograft was not available. Permission for potential use of PTFE graft will be obtained from all cases of LDLT using a right lobe graft. This study protocol is approved by the institutional review board for clinical study.

Interventions

PROCEDUREMHV reconstruction

MHV reconstruction with PTFE or homograft

Sponsors

Asan Medical Center
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Living donor liver transplantation requiring MHV reconstruction

Exclusion criteria

* Living donor liver transplantation not requiring MHV reconstruction

Design outcomes

Primary

MeasureTime frameDescription
Patency of the reconstructed MHVFollow-up for 1 yearPatency rate up to 1 year

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026