Skip to content

IRB-HSR# 15084 A Prospective, Unblinded, Controlled Study to Evaluate the Effect of the ITPR in Patients Undergoing OPCAB Surgery

IRB-HSR# 15084 A Prospective, Unblinded, Controlled Study to Evaluate the Effect of the ITPR in Patients Undergoing OPCAB Surgery

Status
UNKNOWN
Phases
Phase 2
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01205620
Enrollment
30
Registered
2010-09-20
Start date
2010-08-31
Completion date
Unknown
Last updated
2010-09-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

CABG

Keywords

CABG

Brief summary

Participants undergoing Off-CABG will be randomized 1:1 to one of the following groups: * treatment with CirQlator TM Intrathoracic Pressure Regulator (ITPR) * no ITPR .Anesthesia will be standardized for both groups. The groups will be compared based on the differences in vasopressor use, the number and amount (in milliliters) of intravenous fluid boluses required and hemodynamic changes noted, including systemic blood pressure, pulmonary arterial pressure, pulse pressure, heart rate (recorded most reliably from the arterial line), cardiac output (CO), cardiac index (CI), mixed venous oxygen saturation (SVO2), SVR, pulmonary vascular resistance (PVR), and stroke volume (SV). Specifically, we will compare the groups based on the mean number of intravenous fluid boluses, mean amount of norepinephrine and epinephrine infusion required, the number of recorded systolic blood pressures \< 90 mmHg, and number of CI \< 2.0 L/min/m2. We will also compare the number of times the surgeon must reposition the heart for treatment of hypotension, and ascertain whether the ITPR will help patients tolerate the cardiac displacement better, thus decreasing the time required to complete the bypass graft anastamosis. ECG will be monitored intraoperatively for signs of ischemia including ST changes, greater than 1mm depression or elevation. Postoperatively, we will record the need for and amount of diuretic required. We hypothesize that in this pilot study, patients undergoing OPCAB who are treated with CirQlator TM Intrathoracic Pressure Regulator (ITPR) will achieve higher blood pressures and cardiac output and require less intravenous fluids and vasopressor administration than patients managed without the ITPR.

Detailed description

A new method to improve cardiac performance during OPCAB surgery is needed in order to avoid the administration of large amounts of intravenous volume, reduce vasopressor medications, and thus improve cardiac function and reduce the need for postoperative diuresis. The CirQlator TM Intrathoracic Pressure Regulator (ITPR) is an FDA-approved device intended to increase circulation and blood pressure in hypovolemic and cardiogenic shock. The device is inserted within a standard respiratory circuit between the patient and the ventilator. It functions by decreasing intrathoracic pressure during the expiratory phase to subatmospheric levels after each positive pressure ventilation. The decrease in intrathoracic pressure creates a vacuum within the thorax relative to the rest of the body thereby enhancing blood return to the heart and consequently increasing cardiac output and blood pressure. Activation of the device is also accompanied by a decrease in systemic vascular resistance (SVR). The end result is a device that simultaneously improves cardiac output by increasing preload and decreasing systemic vascular resistance (SVR) while increasing coronary perfusion pressure by increasing blood pressure and decreasing left ventricular end systolic pressure and volume (LVESP/LVESV).7-14

Interventions

DEVICEITPR

• Upon incision of the pericardium the -9 mmHg ITPR device will be applied to the patient's endotracheal tube (in the ITPR randomized group).

OTHERNo intervention

No intervention will be performed in the control group

Sponsors

University of Virginia
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patients presenting for elective off-pump CABG age 18 years of age and older informed consent has been obtained

Exclusion criteria

* Patients with planned on pump CABG patients requiring IABP or VAD pre-operatively emergent CABG pneumothorax hemothorax uncontrolled bleeding uncontrolled hypertension defined as SBP \> 180 mmHg at the time of surgery

Design outcomes

Primary

MeasureTime frameDescription
hemodynamic changesduring surgeryhemodynamic changes noted, including systemic blood pressure, pulmonary arterial pressure, pulse pressure, heart rate (recorded most reliably from the arterial line), cardiac output (CO), cardiac index (CI), mixed venous oxygen saturation (SVO2), SVR, pulmonary vascular resistance (PVR), and stroke volume (SV).

Secondary

MeasureTime frameDescription
use of vasopressorsduring surgerythe specific drug and dos will be comparedage used during surgery
IV fluids administeredduring surgerythe type & amount of fluid administered suring surgery will be compared
the number of times the surgeon must reposition the heart for treatment of hypotensionduring surgerythe number of times the surgeon must reposition the heart for treatment of hypotension will be compared, and ascertain whether the ITPR will help patients tolerate the cardiac displacement better, thus decreasing the time required to complete the bypass graft anastamosis.
cardiac ischemiaduring surgeryECG will be monitored intraoperatively for signs of ischemia including ST changes, greater than 1mm depression or elevation.
diuretics administered48 hours after surgeryPostoperatively, we will record the need for and amount of diuretic required.for the first 48 hours post-operatively.

Countries

United States