Chronic Renal Failure
Conditions
Keywords
chronic renal failure, hemodiafiltration
Brief summary
This study is designed to assess the safety, efficacy and dialytic capabilities of hemodiafiltration with on-line prepared substitution fluid using the AK200 ULTRA in comparison to conventional hemodialysis.
Detailed description
The AK200 ULTRA is a new device in the United States, but has been used for several years in Europe. The AK200 ULTRA is a single unit which is preprogrammed to provide standard hemodialysis as well as hemofiltration and hemodiafiltration with on-line preparation of the substitution fluid The AK200 ULTRA hemofiltration and hemodiafiltration is performed using a high flux membrane with high ultrafiltration rates compensated by volumetrically controlled infusion of on-line prepared substitution fluid. The AK200 ULTRA is, therefore, capable of providing dialysis treatments which can improve the removal of medium to high weight molecules without the difficulties associated with the manual measurement and administration of external substitution fluid. This study is designed to assess the safety, efficacy and dialytic capabilities of hemodiafiltration with on-line prepared substitution fluid using the AK200 ULTRA in comparison to conventional hemodialysis. This study is motivated by the need for a commercially available product capable of administering hemofiltration and hemodiafiltration in a clinical setting. The ultimate goal of this study is to improve morbidity and mortality in the ESRD patient population in the United States.
Interventions
hemodiafiltration with the Gambro AK 200 ULTRA
On line hemodiafiltration with the Gambro AK 200 ULTRA System
Sponsors
Study design
Eligibility
Inclusion criteria
1. Subject received chronic dialysis therapy 2. Subject was stable on three dialysis sessions per week 3. Subject was able to understand and sign the informed consent
Exclusion criteria
) On chronic renal replacement therapy for less than three (3) months 2) Hospitalization for reasons other than vascular access complications in the past three (3) months 3) HIV + 4) Hepatitis B+ 5) Pregnancy, verified by pregnancy test for women of child bearing potential 6) Access recirculation \> 10% 7) Hematocrit less than 26% 8) History of non compliance 9) Pediatric patients, defined as less than 18 years old
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Primary Goal: To assess the safety and efficacy of hemodiafiltration with on-line prepared substitution fluid using the AK200 ULTRA for the treatment of chronic renal failure. | 6 months |
Countries
United States