Skip to content

Comparison of the Diagnostic Accuracy of 3D Volume Acquisition MRI With CT in Staging Colonic Cancer

Comparison of the Diagnostic Accuracy of 3D Volume Acquisition MRI With CT in Staging Colonic Cancer

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01187641
Enrollment
60
Registered
2010-08-24
Start date
2010-08-18
Completion date
2016-05-17
Last updated
2017-06-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Colon Cancer

Keywords

cancer, colon, MRI scan

Brief summary

The purpose of this study is to determine whether MRI is more accurate than CT in determining the T stage, N stage, depth of tumour invasion and extra mural venous invasion (EMVI) preoperatively in colon cancer.

Detailed description

The patient will proceed with their usual colon cancer assessment and treatment, including colonoscopy with biopsy and histology and preoperative CT chest abdomen and pelvis. In addition, patients who enroll in the study will have 2 preoperative MRIs of their abdomen and pelvis performed. One of these will be performed on a 1.5T and the other will be performed on a 3.0T MRI scanner. We will use 20mg of IM buscopan to reduce bowel mobility for each scan. A coronal scout scan will be taken to identify the tumour and select the target volume. IV gadolinium (a contrast agent routinely used in MRI scans to help identify different tissues) will be administered, and a 3D VIBE scan (T1 weighted) will be performed of the target volume. The liver will also be imaged at this time to look for liver metastases. A T2 weighted 3D volume acquisition will then be obtained of the target volume containing the tumour (and its lymphatic drainage). The MRI will be independently reported by an expert without knowledge of the results of any other investigations. The results of the MRI scan will then be made available to the clinical team. The patient will then proceed as normal with any other investigation which the clinical team feel is necessary, and be treated as normal for their colon cancer. The patient will proceed with their surgery as normal, and the specimen removed at the time of the operation will be examined in the pathology laboratory to determine the exact stage of the cancer. The accuracy of CT and MRI in staging colon cancer will then be determined against the reference standard provided by the histology examination.

Interventions

None listed

Sponsors

Royal Marsden NHS Foundation Trust
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* patients undergoing treatment for colon cancer * patients undergoing primary surgery for colon cancer and who do not require neo-adjuvant therapy on the basis of their pre-operative CT

Exclusion criteria

* age \<18 * unable to consent * consent withheld or withdrawn * Unable to have an MRI (e.g pacemaker, metal implant) * Allergy or contraindications to busocopam, gadolinium, small bowel contrast agent

Design outcomes

Primary

MeasureTime frame
The primary endpoint will be the accuracy of MRI and CT in determining T stage using histology as the gold standard, on a per patient basis.

Secondary

MeasureTime frame
Secondary endpoints will be the accuracy of CT and MRI in determining N stage, depth of invasion beyond the muscularis propria, and EMVI.
We will also compare the accuracy of 1.5T against 3.0T MRI scans, and T2 weighted against T1 weighted images

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026