Skip to content

Comparative Study of Ologen Collagen Matrix Versus Mitomycin-C in Trabeculectomy: A Study in Germany

A Prospective Randomized Comparative Study of the Safety and Effectiveness of Ologen Collagen Matrix Versus Mitomycin-C in Trabeculectomy

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01174420
Enrollment
40
Registered
2010-08-03
Start date
2009-11-30
Completion date
2011-11-30
Last updated
2011-05-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Open-angle Glaucoma

Keywords

ologen, Mitomycin-C, Collagen Matrix, trabeculectomy, glaucoma, filtering surgery

Brief summary

The aim of this prospective randomized study is to investigate the efficacy and safety of trabeculectomy with ologen Collagen Matrix versus trabeculectomy using mitomycin C (MMC) in patients with medically uncontrolled open angle glaucoma.

Detailed description

ologen® Collagen Matrix (CM) is an artificial extracellular matrix (ECM) specifically configured to support repair in connective and epithelial ocular tissue. The device is constructed so as to minimize random growth of fibroblasts and instead to allow them to grow through the pores in the matrix. ologen® CM is a biodegradable scaffold matrix, inducing a regenerative non-scarring wound healing process without using anti-fibrotic agents. For application in glaucoma filtration surgery, ologen® CM is designed to prevent scar formation (subconjunctival and scleral flap scarring is the major risk factor for failure of trabeculectomy). After implanting the ologen® CM on top of the scleral flap in the subconjunctival space, a functional bleb can be created. The aim of the present study is to determine the effectiveness of the ologen® CM and reduce wound scarring, thereby increasing success of trabeculectomy without side effects of MMC. A means of producing better success rate and reduced complications is the purpose of ologen® Collagen Matrix for the aid of glaucoma surgery.

Interventions

DEVICEUse of ologen Collagen Matrix in trabeculectomy

After trabeculectomy, place ologen Collagen Matrix on the top of the scleral flap under the conjunctiva before suturing

DRUGUse of Mitomycin-C in trabeculectomy

After creating a scleral flap, a sponge with Mitomycin-C (0.02%) is applied on the scleral surface for 3 minutes. Afterwards, Mitomycin-C was rinsed out with balanced salt solution.

Sponsors

Aeon Astron Europe B.V.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 18 years or over * Uncontrolled open-angle glaucoma * Subject is willing to sign informed consent * Subject is able and willing to complete post-operative follow-up requirements

Exclusion criteria

* Inflammatory eye diseases * Angle-closure glaucoma * Secondary glaucoma with anatomical malformations of the eye * Subjects having single functional eye * Previous conjunctival surgery * Known allergic reactions to ingredients of ologen Collagen Matrix * Excessive myopia (axial length (AL)\> 27 mm or more than -10 diopters) * Previous vitrectomy eye surgery * Subjects do not consent to participate

Design outcomes

Primary

MeasureTime frame
Intraocular pressure (IOP) reduction6 months

Secondary

MeasureTime frame
Incidence of complications6 months

Countries

Germany

Contacts

Primary ContactThomas Dietlein, MD
thomas.dietlein@uk-koeln.de+49-221-478-5862

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026