Does the VTS1000 Infra Red Vein Imager Allow Better Identification of Veins Than Normal Eyesight?

Validation of Vue Tek Digital Vein Viewing Device

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01138228
Acronym
VFvalidation
Enrollment
106
Registered
2010-06-07
Start date
2010-02-28
Completion date
2010-02-28
Last updated
2010-06-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vision

Keywords

intravenous cannulation, vein identification, vascular identification, vein cannulation

Brief summary

VueTek has developed a head mounted device that will improve the viewing of superficial, subcutaneous vasculature, differentiating it with higher contrast from surrounding tissue. Video of the vasculature is displayed to the user in a portable headset. The headset and display combination facilitates both visualization in the display and an open field of view directly to the subject's anatomy and practitioner's surroundings. The goal is to provide a non-diagnostic, enhanced visual aide that is used alongside standard visual and tactile methodology. The primary and secondary objectives of this validation are as follows: 1. Primary Objective: To demonstrate that the VTS1000 affords visualization of superficial, subcutaneous vascular structures, when compared to the naked eye. 2. Secondary Objective: To demonstrate that the VTS1000 enhances visualization of superficial, subcutaneous vascular structures over the naked eye. Validation Ancillary Endpoints 1\. To gather data to demonstrate that the VTS1000 is portable, affords conventional vascular access methods, and provides flexibility, fit and balance during use.

Detailed description

Validation methodology: Ten (10) or more independent qualified practitioners trained to operate the device in accordance with the Directions For Use (DFU), and after completing the Device Usability aspect of the study, will be asked to perform simulated procedures with and without the device as indicated in the DFU on one-hundred (100) or more subjects using the following subject population and sampling table. A minimum of one hundred (100) or more data collection observations will be recorded, tabulated and reported. Assumptions: The population and sampling sizes chosen for each subject category will meet the goal to attain sufficient diversity to satisfy representation that supports the efficacy of the device across the population samples. Any failures or results from the acceptance criteria may require an increase in the sampling size to ensure coverage representation of all subject demographics.

Interventions

None listed

Sponsors

Vue Tek Scientific
CollaboratorUNKNOWN
St. Luke's-Roosevelt Hospital Center
Lead SponsorOTHER

Study design

Observational model
CASE_CROSSOVER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
4 Weeks to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Inclusion Criteria: All subjects will be automatically enrolled on a walk-in basis. 2.

Exclusion criteria

No walk-in subjects will be excluded from enrollment.

Design outcomes

Primary

MeasureTime frameDescription
To demonstrate that the VTS1000 affords visualization of superficial, subcutaneous vascular structures, when compared to the naked eye.ImmediateTen (10) or more independent qualified practitioners trained to operate the device in accordance with the Directions For Use (DFU), and after completing the Device Usability aspect of the study, will be asked to perform simulated procedures with and without the device as indicated in the DFU on one-hundred (100) or more subjects using the following subject population and sampling table. A minimum of one hundred (100) or more data collection observations will be recorded, tabulated and reported.

Secondary

MeasureTime frameDescription
To demonstrate that the VTS1000 enhances visualization of superficial, subcutaneous vascular structures over the naked eye.ImmediateTen (10) or more independent qualified practitioners trained to operate the device in accordance with the Directions For Use (DFU), and after completing the Device Usability aspect of the study, will be asked to perform simulated procedures with and without the device as indicated in the DFU on one-hundred (100) or more subjects using the following subject population and sampling table. Number of veins identified by normal vision is compared to number of veins identified with the device in a counter balanced design.

Countries

United States