Skip to content

Acoustic Radiation Force Impulse-Imaging in Comparison to Transient Elastography for Liver Fibrosis Staging in HCV

Performance of Acoustic Radiation Force Impulse-Imaging in Comparison to Transient Elastography for the Non-invasive Staging of Liver Fibrosis in Patients With Chronic Hepatitis C

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01113814
Enrollment
Unknown
Registered
2010-04-30
Start date
Unknown
Completion date
Unknown
Last updated
2012-05-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Chronic Hepatitis C

Brief summary

This study will evaluate the effectiveness of Acoustic Radiation Force Impulse (ARFI)- Imaging compared to Transient Elastography (FibroScan) in differentiating liver fibrosis in patients with chronic hepatitis C. Patients who are scheduled to have a liver biopsy will also undergo ARFI and FibroScan testing. The liver biopsy will be used as the reference method. The target sample size is 433.

Interventions

DEVICEFibroScan
DEVICEAcoustic Radiation Force Impulse (ARFI)- Imaging

Sponsors

Johann Wolfgang Goethe University Hospital
Lead SponsorOTHER

Study design

Primary purpose
DIAGNOSTIC

Eligibility

Sex/Gender
ALL
Age
18 Years to 79 Years
Healthy volunteers
No

Inclusion criteria

* Male or female, 18-79 years old * Written consent * Chronic Hepatitis C infection * Liver biopsy planned or performed within the last six months * In addition, 10 patients/center with proven liver cirrhosis without present liver biopsy can be included

Exclusion criteria

* Consuming illness (HIV infection, malignoma) * Comorbidities associated to HCV (HBV, NASH, hemochromatosis, primary sclerosing cholangitis, primary biliary cirrhosis * Antiviral therapy between liver biopsy and study inclusion * Pacemaker or heart defibrillator * Pregnancy or lactation * Liver transplantation

Design outcomes

Primary

MeasureTime frameDescription
Non-inferiority of AUROCs of Acoustic Radiation Force Impulse (ARFI)- Imaging to Transient Elastography (Fibroscan) for assessment of liver fibrosis in patients with chronic hepatitis C using liver biopsy as the reference standard.The diagnostic accuracy measured with the Area under the ROC curve (AUROC) is calculated for Acoustic Radiation Force Impulse (ARFI)- Imaging and Transient Elastography (Fibroscan) using histology obtained by liver biopsy as reference method in patients infected with chronic hepatitis C. The ROC curve represents sensitivity versus 1-specificity for all possible cut-off values for prediction of the different fibrosis stages, respectively. The areas under the curves (AUROC) as well as 95 % CI of AUROC are calculated.

Secondary

MeasureTime frame
Comparison of AUROC of ARFI-Imaging and Transient Elastography with FibroMax (liver fibrosis marker)
Comparison of AUROC of ARFI and Transient Elastography with the European Liver Fibrosis-Group Marker (ELF)
Evaluation of a combination of non-invasive methods for optimising AUROC for the assessment of liver fibrosis
Evaluation of factors associated with measurement failure of ARFI-Imaging and Transient Elastography
Assessment of center variability of results

Countries

France, Germany, Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026