Skip to content

Non Invasive Imaging of Abdominal Aorta Aneurysm Hemodynamics and Wall Structure

Non Invasive in Vivo Evaluation of Abdominal Aorta Aneurysm Hemodynamics, Wall Stress, and Inflammation Using Magnetic Resonance Imaging

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT01104688
Enrollment
20
Registered
2010-04-15
Start date
2010-03-31
Completion date
2012-03-31
Last updated
2015-01-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Aneurysm, Abdominal

Keywords

Abdominal Aortic Aneurysm, Wall Stress, Shear Stress, Inflammation, Magnetic Resonance Imaging

Brief summary

The development of the abdominal aorta aneurysm is multifactorial. Through use of magnetic resonance imaging without contrast, this study will look closely at flow, the stresses hereby induced, as well as signs of inflammation in the vessel wall.

Detailed description

The etiology of the abdominal aorta aneurysm is complex and multi-factorial. Biomechanic and hemodynamic stress contributes to aneurysmal growth, and the relevance of inflammation is gaining in terms of pathological influence. The technical advances of imaging now enable one to utilize magnetic resonance in reconstructing aortal blood flow. Newer post-imaging software then enables one to perform complex data analysis, wherein shear and wall-stress can be calculated. The goal of this study is to analyze the aneurysms of twenty patients. Values will be obtained for shear and wall stress. Additionally, the utilization of short tau wave inversion recovery (STIR) sequences will be performed to evaluate the presence or absence of acute edema and inflammation of the region. It should also be noted that particular attention will be placed on the so-called neck of the aneurysm, where the aneurysm typically tapers into what is often regarded as normal aortic tissue. This region is important for both the placement of a surgical bypass prosthesis or a deployed stent graft.

Interventions

None listed

Sponsors

Aarhus University Hospital
Lead SponsorOTHER

Study design

Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
20 Years to 90 Years
Healthy volunteers
Yes

Inclusion criteria

* Infrarenal abdominal aorta aneurysm (AAA)

Exclusion criteria

* Lack of signed, informed consent * Pacemaker or other implanted metal prostheses * Claustrophobia * Dementia * Diabetes Mellitus * Thoracoabdominal aorta aneurysm, per Crawford/Safi criteria * Ehlers-Danlos, Marfans, or other diagnosed connective tissue disease

Design outcomes

Primary

MeasureTime frame
Left ventricular longitudinal strain for perioperative cardiac monitoring in aortic aneurysm surgery using transthoracic 2-dimensional echocardiography: a a feasibility and repeatability study.feasibility and repeatability study.12 Months

Countries

Denmark

Outcome results

None listed