2.4 mm Variable Angle LCP Two-Column Volar Distal Radius

A Prospective Multicenter Case-series of Patients Treated With the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01103297
Acronym
VALCP2010
Enrollment
74
Registered
2010-04-14
Start date
2010-06-30
Completion date
2014-05-31
Last updated
2014-09-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Distal Radius Fractures

Keywords

Distal radius fracture, Double row plate, Volar approach, DVR plate, Postoperative complications [MeSH]

Brief summary

The purpose of this study is to is to evaluate the postoperative loss of reduction rate in patients with distal radius fractures treated using the 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate ®.

Detailed description

The treatment of choice for distal radius fractures is anatomic reduction with stable fixation. This is commonly achieved via open reduction and internal fixation with angle-stable designed locking plates using either a volar or dorsal approach. Frequent complications of tendinitis are associated with the latter approach. Palmar application of angle-stable plates reduces this problem of extensor tendon irritation; however a high incidence of fracture collapse has been documented. Currently, there are no existing locking plates that provide sufficient stability particularly for complex fractures. Insufficient fragment fixation can result in loss of reduction due to interfragmentary movement and lead to mal- or nonunion. The Variable Angle LCP Two-Column Volar DR plate (VA LCP DR) is a novel development of the LCP Distal Radius Plate System, which is designed to treat a wide variety of distal radius fracture patterns. Because of its design (ie, low plate and screw profile, polished surface, rounded edges, various locking options), not only can the potential for tendon adhesions and soft tissue irritation be minimized, the plate can address fragments individually for each fracture type. Thus, the versatility of VA LCP facilitates the reduction and stabilization of even the most complex fractures, including those in osteoporotic bone. This prospective case-series will evaluate the performance of the new VA LCP DR plate in the treatment of complex articular fractures of the distal radius. The primary objective of this study involves the documentation of postoperative loss of reduction; functional outcomes, quality of life and rate of complications associated with fracture fixation will also be assessed as part of the secondary study aims.

Interventions

DEVICEVariable Angle Distal Radius Plate ® (Surgery)

Fracture reduction with distal radius plate

Sponsors

AO Clinical Investigation and Publishing Documentation
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients aged ≥ 18 years * Patients with closed, partial or complete articular distal radius fractures classified as: AO 23 B3 and AO 23 C1, C2, C3 confirmed by CT scan * Definitive primary fracture treatment with a VA LCP DR * The patient is willing and able to participate in the study follow-up examinations according to the protocol * The patient is able to understand and read the local language at an elementary level * The patient or his/her legal guardian is willing and able to give his informed consent to participate in the study * Woman must be one of the following: * Postmenopausal defined as amenorrhea for at least 6 months before screening and a serum follicle stimulating hormone (FSH) level consistent with postmenopausal status * Surgically sterile, (have had a hysterectomy or bilateral oophorectomy, tubal ligation, or otherwise be incapable of pregnancy) * Abstinent (at the discretion of the investigator) or, * If sexually active, be practicing an effective method of birth control such as hormonal prescription oral contraceptives, progesterone implants or injections, intrauterine device (IUD), a double-barrier method such as condoms, diaphragms or cervical caps with spermicidal foam, cream or gel, or male partner with a vasectomy. * Women of childbearing potential must have a negative serum β-human chorionic gonadotropin (β-hCG) pregnancy test, or a negative urine pregnancy test at screening.

Exclusion criteria

* Previous ipsilateral distal radius fracture * Other fractures of the ipsilateral side (except ulna) * Pathologic fracture due to malignancy * The patient suffers from a polytrauma * The patient is affected by drug or alcohol abuse * The patient suffers from active malignancy * Neurological and psychiatric disorders * The patient has participated in any other device or drug related clinical trial within the previous month * The patient is a prisoner * Breast feeding woman

Design outcomes

Primary

MeasureTime frameDescription
Loss of reductionover 1 yearLoss of reduction will be defined as the change in measurement\* determined to 0.5 mm or 1 degree of accuracy: \*Any change in angles, length or secondary fragment displacement (ie, radial height (length), radial inclination, ulnar variance, gap, step-off, palmar tilt (inclination) / dorsal tilt, scapholunate angle, teardrop angle, and the AP distance).

Secondary

MeasureTime frameDescription
Wrist function12 weeksBilateral Range of motion (ROM)
Grip strength12 weeksWith Jamar dynamometer
Rate of fracture fixation complicationsBaseline
Quality of LifeBaselineHealth-related quality of life (EQ5D)
Implantation and system feedbackBaseline
Wrist pain and disability in functional activitiesBaselinePatient self-assessment of wrist function questionnaire (PRWE)