Skip to content

A Comparison of the Pacemaker Automatic Features in Reduction of Ventricular Pacing

Study of a Comparison of the Pacemaker Automatic Features in Reduction of Ventricular Pacing

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01039467
Acronym
COMPARE
Enrollment
385
Registered
2009-12-25
Start date
2009-06-30
Completion date
2014-04-30
Last updated
2020-02-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bradycardia

Keywords

Managed Ventricular Pacing

Brief summary

The COMPARE-Adapta study is a randomized, multi-center, prospective study conducted in China. The purpose of the study is to compare the ability of Search AV™+ and Managed Ventricular Pacing® (MVP®) to reduce ventricular pacing in dual chamber pacemaker-indicated patients. The COMPARE-Adapta study will also observe atrial fibrillation (AF) burden as demonstrated by Cardiac Compass® and the clinical profile Adapta® pacemaker patients.

Detailed description

Recent studies suggest that chronic right ventricular pacing is associated with a variety of adverse effects in patients, particularly those with intact or intermittent atrioventricular (AV) conduction. Medtronic Adapta® pacemakers include Managed Ventricular Pacing®, a pacing mode designed to promote intrinsic conduction, and also Search AV™+, a feature designed to reduce unnecessary ventricular pacing in patients with intact or intermittent AV conduction.

Interventions

DEVICEMedtronic Adapta Dual Chamber Pacemaker

Medtronic Adapta Dual Chamber Pacemaker

Sponsors

Medtronic Cardiac Rhythm and Heart Failure
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Signed and dated study informed consent * Class I or Class IIa pacemaker indication * Geographically stable and available for follow-up at the center for the length of the study * Age greater than 18 * To be implanted with Adapta dual chamber pacemaker

Exclusion criteria

* Unwillingness or inability to give written informed consent to participate in the Study * Patient with a previously implanted pacemaker/Implantable Cardioverter-Defibrillator (ICD)/Cardiac Resynchronization Therapy (CRT) device * Life expectancy of less than one year * Patient has a mechanical tricuspid heart valve * Medical conditions that preclude the testing requirement by the protocol or limit study participation * Patient has persistent 3rd degree atrioventricular (AV) block * Patient has persistent atrial fibrillation (AF) * Patient has neurogenic syncope * Patient has carotid sinus syndrome * Patient has hypertrophic obstructive cardiomyopathy * Inclusion in another clinical trial or study

Design outcomes

Primary

MeasureTime frame
Number of Participants With Decreased Percent of Ventricular Pacing Compared to MVP Using Search AV+1 month post-implantation

Secondary

MeasureTime frameDescription
Percentage of Reduced Percent of Atrial Fibrillation (AF) Burden 1-month Post-Implant1 month post-implantationTo compare the ability of Search AV™+ and Managed Ventricular Pacing® (MVP®) to reduce ventricular pacing in dual chamber pacemaker-indicated patients by measuring the percent burden of atrial fibrillation (AF) burden as demonstrated by Cardiac Compass® and the clinical profile Adapta® pacemaker patients.
Change in Percent of Ventricular Pacingfrom 1 month to 12 months post-implantation
Number of Participants With Percent Ventricular Pacing Reduced to Lower Levels (<10%VP)1 month post-implantation
Percent of Ventricular Pacing12 months post-implantation
Percent of Ventricular Pacing Stratified by Baseline AV Block Status (1st Degree - 1AVB)1 month post-implantation
Percent of Ventricular Pacing Stratified by Baseline AV Block Status (2nd Degree Type I & II - 2AVB)1 month post-implantation
Percent of Ventricular Pacing Stratified by Baseline AV Block Status (3rd Degree Episodic - e3AVB)1 month post-implantation
Number of Participants With Decreased Percent Ventricular Pacing Stratified by Baseline Atrioventricular Block Status (No AVB - nAVB)1 month post-implantation

Countries

China

Participant flow

Recruitment details

Enrollment period: 18 JUN 2009 to 15 MAR 2010.

Pre-assignment details

6 patients withdrawn from study pre-randomization for not meeting inclusion/exclusion criteria.

Participants by arm

ArmCount
Managed Ventricular Pacing (MVP)
Managed Ventricular Pacing (MVP) used in dual chamber pacemaker
196
Search AV+
Search AV+ used in dual chamber pacemaker
189
Total385

Baseline characteristics

CharacteristicManaged Ventricular Pacing (MVP)Search AV+Total
Age, Continuous69.87 years
STANDARD_DEVIATION 10.35
70.71 years
STANDARD_DEVIATION 9.89
70.28 years
STANDARD_DEVIATION 10.12
Region of Enrollment
China
196 participants189 participants385 participants
Sex: Female, Male
Female
93 Participants81 Participants174 Participants
Sex: Female, Male
Male
103 Participants108 Participants211 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
— / —— / —
other
Total, other adverse events
2 / 1963 / 189
serious
Total, serious adverse events
2 / 1967 / 189

Outcome results

Primary

Number of Participants With Decreased Percent of Ventricular Pacing Compared to MVP Using Search AV+

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with %VP data available.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Managed Ventricular PacingNumber of Participants With Decreased Percent of Ventricular Pacing Compared to MVP Using Search AV+1 Participants
Search AV+Number of Participants With Decreased Percent of Ventricular Pacing Compared to MVP Using Search AV+4 Participants
p-value: <0.0001Wilcoxon (Mann-Whitney)
Secondary

Change in Percent of Ventricular Pacing

Time frame: from 1 month to 12 months post-implantation

Population: all participants who completed the 12 months visit with %VP data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingChange in Percent of Ventricular Pacing-0.10 percent of ventricular pacing (%VP)Standard Deviation 20.2
Search AV+Change in Percent of Ventricular Pacing0.00 percent of ventricular pacing (%VP)Standard Deviation 20.18
p-value: 0.265Wilcoxon (Mann-Whitney)
Secondary

Number of Participants With Decreased Percent Ventricular Pacing Stratified by Baseline Atrioventricular Block Status (No AVB - nAVB)

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with %VP data available.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Managed Ventricular PacingNumber of Participants With Decreased Percent Ventricular Pacing Stratified by Baseline Atrioventricular Block Status (No AVB - nAVB)1 Participants
Search AV+Number of Participants With Decreased Percent Ventricular Pacing Stratified by Baseline Atrioventricular Block Status (No AVB - nAVB)1 Participants
p-value: <0.0001Wilcoxon (Mann-Whitney)
Secondary

Number of Participants With Percent Ventricular Pacing Reduced to Lower Levels (<10%VP)

Time frame: 1 month post-implantation

Population: all participants who completed the 12 months visit with %VP data available.

ArmMeasureValue (COUNT_OF_PARTICIPANTS)
Managed Ventricular PacingNumber of Participants With Percent Ventricular Pacing Reduced to Lower Levels (<10%VP)132 Participants
Search AV+Number of Participants With Percent Ventricular Pacing Reduced to Lower Levels (<10%VP)91 Participants
p-value: <0.0001Chi-squared
Secondary

Percentage of Reduced Percent of Atrial Fibrillation (AF) Burden 1-month Post-Implant

To compare the ability of Search AV™+ and Managed Ventricular Pacing® (MVP®) to reduce ventricular pacing in dual chamber pacemaker-indicated patients by measuring the percent burden of atrial fibrillation (AF) burden as demonstrated by Cardiac Compass® and the clinical profile Adapta® pacemaker patients.

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with~%AT/AF burden data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingPercentage of Reduced Percent of Atrial Fibrillation (AF) Burden 1-month Post-Implant1.40 Percentage of decreasedAT/AF burdenStandard Deviation 20.27
Search AV+Percentage of Reduced Percent of Atrial Fibrillation (AF) Burden 1-month Post-Implant0.50 Percentage of decreasedAT/AF burdenStandard Deviation 25.43
p-value: 0.833Wilcoxon (Mann-Whitney)
Secondary

Percent of Ventricular Pacing

Time frame: 12 months post-implantation

Population: all participants who completed the 12 months visit with %VP data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingPercent of Ventricular Pacing0.40 percent of ventricular pacing (%VP)Standard Deviation 31.46
Search AV+Percent of Ventricular Pacing2.95 percent of ventricular pacing (%VP)Standard Deviation 40.05
p-value: <0.0001Wilcoxon (Mann-Whitney)
Secondary

Percent of Ventricular Pacing Stratified by Baseline AV Block Status (1st Degree - 1AVB)

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with %VP data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingPercent of Ventricular Pacing Stratified by Baseline AV Block Status (1st Degree - 1AVB)1.50 percent of ventricular pacing (%VP)Standard Deviation 23.65
Search AV+Percent of Ventricular Pacing Stratified by Baseline AV Block Status (1st Degree - 1AVB)21.80 percent of ventricular pacing (%VP)Standard Deviation 41
p-value: 0.0008Wilcoxon (Mann-Whitney)
Secondary

Percent of Ventricular Pacing Stratified by Baseline AV Block Status (2nd Degree Type I & II - 2AVB)

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with %VP data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingPercent of Ventricular Pacing Stratified by Baseline AV Block Status (2nd Degree Type I & II - 2AVB)21.40 percent of ventricular pacing (%VP)Standard Deviation 39.16
Search AV+Percent of Ventricular Pacing Stratified by Baseline AV Block Status (2nd Degree Type I & II - 2AVB)80.60 percent of ventricular pacing (%VP)Standard Deviation 44.03
p-value: 0.053Wilcoxon (Mann-Whitney)
Secondary

Percent of Ventricular Pacing Stratified by Baseline AV Block Status (3rd Degree Episodic - e3AVB)

Time frame: 1 month post-implantation

Population: all participants who completed the 1 month visit with %VP data available.

ArmMeasureValue (MEDIAN)Dispersion
Managed Ventricular PacingPercent of Ventricular Pacing Stratified by Baseline AV Block Status (3rd Degree Episodic - e3AVB)79.20 percent of ventricular pacing (%VP)Standard Deviation 44.68
Search AV+Percent of Ventricular Pacing Stratified by Baseline AV Block Status (3rd Degree Episodic - e3AVB)22.45 percent of ventricular pacing (%VP)Standard Deviation 47.13
p-value: 0.493Wilcoxon (Mann-Whitney)

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026