Comparison of the I-gel Laryngeal Mask and the Classic Laryngeal Mask in Patients With a BMI>25

Comparison of the I-gel Laryngeal Mask and the Classic Laryngeal Mask in Patients With a BMI>25 During Elective Surgery

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT01003327
Enrollment
50
Registered
2009-10-28
Start date
2009-10-31
Completion date
2010-04-30
Last updated
2010-07-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intubation, Surgery

Keywords

laryngeal mask, leak pressure, leak pressure

Brief summary

The intention of this study is to compare the performance of the single-use I-gel laryngeal mask with the classic laryngeal mask in 50 patients with a BMI\>25 during elective surgery. Primary outcome is the leak pressure. Secondary outcomes include ease and duration of insertion.

Detailed description

Inclusion criteria of this randomized cross-over study are: BMI \> 25, elective surgery in supine position, age\>18 years, ASA I-II; Exclusion criteria are: difficult airway, pregnancy, history of reflux or gastrointestinal disorders, abdominal or thoracic surgery; In this cross-over trial both airway devices are inserted in the same patient, the order of insertion is randomized. Patient receive monitoring with blood pressure, ECG and pulse oxymetry during operation. Anaesthesia is induced intravenously using fentanyl (0.001 mg/kg) and propofol (3-5 mg/kg). The I-gel laryngeal mask is inserted with a gastric tube. The classic laryngeal mask was cuffed after insertion with a cuff pressure of 60 cmH2O. The first device is removed 5 minutes after insertion and replaced by the second device. Ease of insertion is graded as very easy=1, easy=2, difficult=3 and very difficult=4. Leak pressure is measured by two tests: In the first test the spill valve is closed at a fresh gas flow of 6l/min and the minimum airway pressure at which gas leaked around the airway device is recorded by listening for an audible leak. In the second test leakage is measured during pressure controlled ventilation. Therefore we administer a fresh gas flow of 3l/min, FiO2 of 50%, inspiration to expiration ratio of 1:2 and a frequency of breathing of 12. Leakage can be measured by the respirator. We record inspiration pressure, mean pressure, plateau pressure, tidal volume and peep at which the first measurable leakage occurred. For statistical analysis we will use t-tests with a power of 80% and a p \< 0.05.

Interventions

DEVICEI-gel

intubation with I-gel airway

DEVICELMA-Unique

LMA-Unique airway is inserted first, then the I-gel

Sponsors

Medical University of Vienna
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* BMI \> 25, elective surgery in supine position, * age \> 18 years, * ASA I-II;

Exclusion criteria

* difficult airway, pregnancy, * history of reflux or gastrointestinal disorders, * abdominal or thoracic surgery;

Design outcomes

Primary

MeasureTime frame
leak pressure of the laryngeal masksdirectly after insertion of the laryngeal mask

Secondary

MeasureTime frame
Insertion time and ease of insertion of the laryngeal maskduring insertion of the laryngeal mask